ACE Report Cover
Large femoral heads lead to fewer dislocation rates after revision THA than standard heads
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Idioma
Download Download Download
Descargar
Cite this Report Cite this Report Cite this Report
Citar
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Favoritos
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Idioma
Download Download Download
Descargar
Cite this Report Cite this Report Cite this Report
Citar
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Favoritos
ARTHROPLASTY
Large femoral heads lead to fewer dislocation rates after revision THA than standard heads .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(9):15 Clin Orthop Relat Res. 2012 Feb;470(2):351-6. doi: 10.1007/s11999-011-2146-x

184 patients were randomized to examine the potential of large femoral heads in decreasing the dislocation rate following revision total hip arthroplasty (THA). Patients received either a standard head (32 mm) or a large head (36 or 40 mm), and were assessed at a mean follow-up of 5 years for dislocation and 2.2 years for quality of life (QOL). Results indicated that dislocation rates were lower in patients who received the large head, while there was no difference in QOL between the two groups.


Detalles de la financiación de la publicación +
Financiación:
Industry funded
Patrocinador:
Zimmer, Inc.
Conflicts:
Other

Riesgo de sesgo

6/10

Criterios de información

15/20

Índice de fragilidad

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sí = 1

Incierto = 0,5

No relevante = 0

No = 0

La evaluación de los criterios de información evalúa la transparencia con la que los autores informan de las características metodológicas y del ensayo dentro de la publicación. La evaluación se divide en cinco categorías que se presentan a continuación.

3/4

Randomization

2/4

Outcome Measurements

4/4

Inclusion / Exclusion

2/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

El Índice de Fragilidad es una herramienta que ayuda en la interpretación de hallazgos significativos, proporcionando una medida de fuerza para un resultado. El Índice de Fragilidad representa el número de eventos consecutivos que es necesario añadir a un resultado dicotómico para que el hallazgo deje de ser significativo. Un número pequeño representa un hallazgo más débil y un número grande un hallazgo más fuerte.

¿Por qué se necesitaba ahora este estudio?

Dislocation following revision THA is one of the most common complications. While larger heads have become available to surgeons (where it's head-to-neck ratio could prevent dislocation), there are very few studies that address the effect of head size in revision THA. Hence, this study aimed to determine whether a large femoral head (36 or 40 mm) would result in a decreased dislocation rate compared to a standard head (32 mm) in revision THA.

¿Cuál era la pregunta principal de la investigación?

Will a large femoral head result in a reduction in dislocation rates after revision THA compared to a standard head, assessed over 5 years?

Características del estudio +
Population:
184 patients undergoing revision THA were randomized (n = 179 at follow-up for dislocation and n = 133 at follow-up for QOL).
Intervention:
Large-head group: Patients received a large femoral head (36 or 40 mm diameter) (n = 92; n = 89 at follow-up for dislocation and n = 67 at follow-up for QOL).
Comparison:
Standard-head group: Patients received a standard head (32 mm diameter) (n = 92; n = 90 at follow-up for dislocation and n = 66 at follow-up for QOL).
Outcomes:
All patients completed a self-administered comorbidity score and completed quality-of-life (QOL) questionnaires (through WOMAC and SF-36). Patients were also questioned at each time interval to determine whether they had a dislocation.
Methods:
RCT: Prospective
Time:
Patients were followed at 3, 12, 24, and 60 months postoperatively.
¿Cuáles fueron los hallazgos importantes?
  • The rate of dislocation was lower for the large-head group (1.1% or 1 of 92) than for the standard-head group (8.7% or 8 of 92) (p = 0.035).
  • Of the 8 patients with dislocations in the standard-head group, 5 required no further surgery while the other 3 required further surgery to stabilize the hips; the one patient in the large-head group who was dislocated required further surgery to stabilize the hips.
  • Improvements in all QOL scores from preoperative values were observed in both groups; the only score that was different between the two groups at follow-up was the SF-36 mental component, with the large-head group scoring higher than the standard-head group (p = 0.043).
¿Qué es lo que más debo recordar?

This study demonstrated that there was a significant decrease in dislocation rates when larger 36- or 40-mm heads were used in comparison to standard 32 mm heads. However, no significant difference was observed in terms of quality of life between both groups (except the SF-36 mental component, which favoured the large-head group).

¿Cómo afectará esto al cuidado de mis pacientes?

The results of this study suggest that large-heads should be routinely selected when performing revision THA. However, the effects of using larger heads must be further studied to better understand long-term outcomes of these prostheses.

DESCARGO DE RESPONSABILIDAD

El contenido de esta página tiene únicamente fines informativos y no pretende sustituir el consejo, diagnóstico o tratamiento médico profesional. Si necesita tratamiento médico, busque siempre el consejo de su médico o acuda al servicio de urgencias más cercano. Las opiniones, creencias y puntos de vista expresados por las personas sobre el contenido que se encuentra en esta página no reflejan las opiniones, creencias y puntos de vista de OrthoEvidence.

0 de 4 artículos mensuales GRATIS desbloqueados
Ha alcanzado su límite de vistas de 4 artículos gratuitos este mes

Acceda a OrtoEvidencia por tan sólo 1,99 $ a la semana.

Manténgase conectado con las últimas pruebas. Cancele en cualquier momento.
  • Valoraciones críticas de los últimos ensayos controlados aleatorizados de gran impacto y revisiones sistemáticas en ortopedia
  • Acceso al contenido del podcast OrthoEvidence, que incluye colaboraciones con el Journal of Bone and Joint Surgery, entrevistas con cirujanos reconocidos internacionalmente y mesas redondas sobre noticias y temas ortopédicos
  • Suscripción a The Pulse, un boletín quincenal basado en la evidencia y diseñado para ayudarle a tomar mejores decisiones clínicas
Upgrade
Bienvenido
¿Ha olvidado su contraseña?
Comience hoy mismo su prueba GRATUITA

Su cuenta estará afiliada a
e incluye acceso gratuito a OrthoEvidence


O
¿Olvidó su contraseña?

O
Compruebe su correo electrónico

Si existe una cuenta con la dirección de correo electrónico proporcionada, se le enviará un correo electrónico para restablecer la contraseña. Si no ve el correo electrónico, compruebe su carpeta de correo no deseado o spam.

Si necesita más ayuda póngase en contacto con nuestro equipo de asistencia.

Inicie sesión para activar esta función

Para acceder a esta función, debe iniciar sesión en una cuenta activa de OrthoEvidence. Por favor, inicie sesión o cree una cuenta de prueba GRATUITA.

Traducir Informe ACE

OrthoEvidence utiliza un servicio de traducción de terceros para que el contenido sea accesible en varios idiomas. Tenga en cuenta que, aunque se hace todo lo posible para garantizar la exactitud, las traducciones no siempre son perfectas.

Cómo citar esto ACE Report

OrthoEvidence. Large femoral heads lead to fewer dislocation rates after revision THA than standard heads. OE Journal. 2013;1(9):15. Available from: https://myorthoevidence.com/AceReport/Show/large-femoral-heads-lead-to-fewer-dislocation-rates-after-revision-tha-than-standard-heads