Higher flexion devices in TKA have no effect on patient-perceived outcomes .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(8):8 BMC Musculoskelet Disord. 2013 Apr 8;14(1):127. doi: 10.1186/1471-2474-14-127
Auteurs contributeurs

MG Thomsen H Husted KS Otte G Holm A Troelsen

36 patients undergoing a one-stage bilateral total knee arthroplasty were randomized to receive standard cruciate-retaining (CR) TKA in one knee and high-flex posterior-stabilized (PS) TKA in the other. This trial was designed to investigate whether higher flexion had an effect on patient perceived outcomes. 1 year results through Visual Analogue Scale and Short Form-36 survey indicated no differences in ability to perform daily activities, satisfaction, “feel” of the knee, or pain in either prosthesis.


Détails du financement de la publication +
Financement:
Not Reported
Conflits:
None disclosed

Risque de partialité

7,5/10

Critères de déclaration

18/20

Indice de fragilité

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Oui = 1

Incertain = 0,5

Non pertinent = 0

Non = 0

L'évaluation des critères de rapport permet d'évaluer la transparence avec laquelle les auteurs rapportent les caractéristiques méthodologiques et les caractéristiques de l'essai dans la publication. L'évaluation est divisée en cinq catégories qui sont présentées ci-dessous.

3/4

Randomization

3/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

L'indice de fragilité est un outil qui aide à l'interprétation des résultats significatifs, en fournissant une mesure de la force d'un résultat. L'indice de fragilité représente le nombre d'événements consécutifs qui doivent être ajoutés à un résultat dichotomique pour que le résultat ne soit plus significatif. Un petit nombre représente un résultat plus faible et un grand nombre un résultat plus fort.

Pourquoi cette étude était-elle nécessaire maintenant ?

In total knee arthroplasty, range of motion is considered to be a measurement of functional success. New high flex prosthetic designs have been used, but studies have not been able to show that increased flexion beyond 110 degrees have an influence on patient-perceived outcomes. This trial, therefore, aimed to investigate whether insertion of high flex posterior stabilized TKA had increased patient satisfaction, reduced pain, better “feel” and better abilities in activities of daily living compared to standard cruciate retaining prosthesis.

Quelle était la principale question de recherche ?

Does higher knee flexion, provided by high-flex PS-TKA, affect patient-perceived outcomes, such as pain, satisfaction, ability to perform daily tasks, and "feel" of the knee at 1 year, compared to standard CS-TKA?

Caractéristiques de l'étude +
Population:
36 patients with a mean age of 67.2 years (72 knees) undergoing one-stage bilateral TKA (n=33 patients at follow up).
Intervention:
High flex-PS TKA: Arthroplasty performed using cemented posterior stabilizing LPS-Flex prosthesis (Zimmer, Warsaw, Indiana, USA) in one knee (n=33)
Comparaison:
Standard CR-TKA: Arthroplasty performed using cemented cruciate retaining prosthesis (Biomet-Merck, Warsaw, Indiana, USA) in other knee (n=33)
Résultats:
Active and passive flexion and extension by goniometer; questions about their ability to ride a bike, squat, barriers in daily living, and ability to kneel for each knee; Visual Analog Scale (VAS) questionnaire measuring pain, satisfaction , “feel” of the knee; Short Form-36 (SF-36) questionnaire
Méthodes:
RCT: Single Center: Double Blind
Durée de l'intervention:
1 year (follow-up at 6 weeks, 3 months, 6 months and 1 year postoperatively)
Quels sont les résultats importants ?
  • PS TKA and CR TKA had similar mean maximum active and passive flexion preoperatively, at week 6 and 3 months. However, at 6 months and 1 year, PS TKA had significantly better flexion (p<0.05). By final follow up, 30 of the CR TKA’s and 31 of the high-flex PS TKA’s were able to extend to 0–5 degrees (P>0.05)
  • VAS knee pain was similar in both types of TKA at all-time points (P>0.05).
  • VAS satisfaction did not differ between PS TKA and CR TKA at all-time points (P>0.05)
  • Patient perceived “feel” of the knee was reported to be the same at all-time points between the knees (P>0.05)
  • Satisfaction in ROM during activities of daily living, biking, squatting, facing barriers, were stated to be similar in both prosthesis (P>0.05)
  • For SF-36, 26/33 patients who completed questionnaire had comparable median physical component score (PCS) of 47.8 (range: 20.6-57.9) and median mental component score (MCS) of 59.2 (range: 32.8-64.6)
De quoi dois-je me souvenir en priorité ?

Although high flexion PS prosthesis significantly increased flexion at 12 months compared to standard CR prosthesis, it had no significant effect on patient-perceived results, such as pain, satisfaction, "feel" of the knee, and ability to perform daily activities.

Comment cela affectera-t-il les soins prodigués à mes patients ?

The findings suggest that increasing flexion beyond 110 degrees through high-flex PS prosthesis does not produce better patient related outcomes in this population. Further studies with larger sample sizes should be conducted to suggest the best prosthesis choice across different populations and activity levels.

AVIS DE NON-RESPONSABILITÉ

Le contenu de cette page est fourni à titre d'information uniquement et n'est pas destiné à remplacer un avis médical, un diagnostic ou un traitement professionnel. Si vous avez besoin d'un traitement médical, demandez toujours l'avis de votre médecin ou rendez-vous au service des urgences le plus proche. Les opinions, croyances et points de vue exprimés par les individus sur le contenu de cette page ne reflètent pas les opinions, croyances et points de vue d'OrthoEvidence.

0 de 4 articles mensuels GRATUITS débloqués
Vous avez atteint votre limite de 4 vues d'articles gratuits ce mois-ci

Accédez à OrthoEvidence pour seulement 1,99 $ par semaine.

Restez informé des dernières données. Annulez à tout moment.
  • Évaluations critiques des derniers essais contrôlés randomisés à fort impact et des revues systématiques en orthopédie.
  • Accès au contenu des podcasts OrthoEvidence, y compris les collaborations avec le Journal of Bone and Joint Surgery, les entretiens avec des chirurgiens de renommée internationale et les tables rondes sur l'actualité et les sujets orthopédiques.
  • Abonnement à The Pulse, une lettre d'information bihebdomadaire fondée sur des données probantes, conçue pour vous aider à prendre de meilleures décisions cliniques.
Upgrade
Close Dialog
Bienvenue à nouveau !
Vous avez oublié votre mot de passe ?
Commencez votre essai GRATUIT dès aujourd'hui !

Votre compte sera affilié à
et inclut un accès gratuit à OrthoEvidence.


OU
Vous avez oublié votre mot de passe ?

OU
Veuillez vérifier votre adresse électronique

Si un compte existe avec l'adresse e-mail fournie, un e-mail de réinitialisation du mot de passe vous sera envoyé. Si vous ne voyez pas d'e-mail, veuillez vérifier votre dossier de spam ou de courrier indésirable.

Pour plus d'assistance, contactez notre équipe d'assistance.

Veuillez vous connecter pour activer cette fonction

Pour accéder à cette fonctionnalité, vous devez être connecté à un compte OrthoEvidence actif. Veuillez vous connecter ou créer un compte d'essai GRATUIT.

Traduire le rapport ACE

OrthoEvidence utilise un service de traduction tiers pour rendre le contenu accessible dans plusieurs langues. Veuillez noter que même si tous les efforts sont faits pour assurer l'exactitude, les traductions ne sont pas toujours parfaites.

Comment citer ce document ACE Report

OrthoEvidence. Higher flexion devices in TKA have no effect on patient-perceived outcomes. OE Journal. 2013;1(8):8. Available from: https://myorthoevidence.com/AceReport/Show/higher-flexion-devices-in-tka-have-no-effect-on-patient-perceived-outcomes

Copier la citation
Veuillez vous connecter pour activer cette fonction

Pour accéder à cette fonctionnalité, vous devez être connecté à un compte OrthoEvidence actif. Veuillez vous connecter ou créer un compte d'essai GRATUIT.

Fonctionnalité Membre Premium

Pour accéder à cette fonctionnalité, vous devez être connecté à un compte Premium OrthoEvidence.

Partager ACE Report