ACE Report Cover
Higher flexion devices in TKA have no effect on patient-perceived outcomes
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
اللغة
Download Download Download
تحميل
Cite this Report Cite this Report Cite this Report
اقتباس
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ المفضلة
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
اللغة
Download Download Download
تحميل
Cite this Report Cite this Report Cite this Report
اقتباس
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ المفضلة
ARTHROPLASTY
Higher flexion devices in TKA have no effect on patient-perceived outcomes .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(8):8 BMC Musculoskelet Disord. 2013 Apr 8;14(1):127. doi: 10.1186/1471-2474-14-127
المؤلفون المساهمون

MG Thomsen H Husted KS Otte G Holm A Troelsen

36 patients undergoing a one-stage bilateral total knee arthroplasty were randomized to receive standard cruciate-retaining (CR) TKA in one knee and high-flex posterior-stabilized (PS) TKA in the other. This trial was designed to investigate whether higher flexion had an effect on patient perceived outcomes. 1 year results through Visual Analogue Scale and Short Form-36 survey indicated no differences in ability to perform daily activities, satisfaction, “feel” of the knee, or pain in either prosthesis.


تفاصيل تمويل المنشور +
التمويل:
Not Reported
التعارضات:
None disclosed

مخاطر التحيز

7٫5/10

معايير الإبلاغ

18/20

مؤشر الهشاشة

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

نعم = 1

غير مؤكد = 0.5

غير ذي صلة = 0

لا = 0

يقيّم تقييم معايير الإبلاغ الشفافية التي يبلغ بها المؤلفون عن الخصائص المنهجية والتجريبية للتجربة في المنشور. ينقسم التقييم إلى خمس فئات معروضة أدناه.

3/4

Randomization

3/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

مؤشر الهشاشة هو أداة تساعد في تفسير النتائج المهمة، وتوفر مقياسًا لقوة النتيجة. ويمثل مؤشر الهشاشة عدد الأحداث المتتالية التي يجب إضافتها إلى نتيجة ثنائية التفرع لجعل النتيجة غير مهمة. يمثل الرقم الصغير نتيجة أضعف ويمثل الرقم الكبير نتيجة أقوى.

لماذا كانت هناك حاجة لهذه الدراسة الآن؟

In total knee arthroplasty, range of motion is considered to be a measurement of functional success. New high flex prosthetic designs have been used, but studies have not been able to show that increased flexion beyond 110 degrees have an influence on patient-perceived outcomes. This trial, therefore, aimed to investigate whether insertion of high flex posterior stabilized TKA had increased patient satisfaction, reduced pain, better “feel” and better abilities in activities of daily living compared to standard cruciate retaining prosthesis.

ما هو سؤال البحث الرئيسي؟

Does higher knee flexion, provided by high-flex PS-TKA, affect patient-perceived outcomes, such as pain, satisfaction, ability to perform daily tasks, and "feel" of the knee at 1 year, compared to standard CS-TKA?

خصائص الدراسة +
Population:
36 patients with a mean age of 67.2 years (72 knees) undergoing one-stage bilateral TKA (n=33 patients at follow up).
Intervention:
High flex-PS TKA: Arthroplasty performed using cemented posterior stabilizing LPS-Flex prosthesis (Zimmer, Warsaw, Indiana, USA) in one knee (n=33)
Comparison:
Standard CR-TKA: Arthroplasty performed using cemented cruciate retaining prosthesis (Biomet-Merck, Warsaw, Indiana, USA) in other knee (n=33)
Outcomes:
Active and passive flexion and extension by goniometer; questions about their ability to ride a bike, squat, barriers in daily living, and ability to kneel for each knee; Visual Analog Scale (VAS) questionnaire measuring pain, satisfaction , “feel” of the knee; Short Form-36 (SF-36) questionnaire
Methods:
RCT: Single Center: Double Blind
Time:
1 year (follow-up at 6 weeks, 3 months, 6 months and 1 year postoperatively)
ما هي النتائج المهمة؟
  • PS TKA and CR TKA had similar mean maximum active and passive flexion preoperatively, at week 6 and 3 months. However, at 6 months and 1 year, PS TKA had significantly better flexion (p<0.05). By final follow up, 30 of the CR TKA’s and 31 of the high-flex PS TKA’s were able to extend to 0–5 degrees (P>0.05)
  • VAS knee pain was similar in both types of TKA at all-time points (P>0.05).
  • VAS satisfaction did not differ between PS TKA and CR TKA at all-time points (P>0.05)
  • Patient perceived “feel” of the knee was reported to be the same at all-time points between the knees (P>0.05)
  • Satisfaction in ROM during activities of daily living, biking, squatting, facing barriers, were stated to be similar in both prosthesis (P>0.05)
  • For SF-36, 26/33 patients who completed questionnaire had comparable median physical component score (PCS) of 47.8 (range: 20.6-57.9) and median mental component score (MCS) of 59.2 (range: 32.8-64.6)
ما الذي يجب أن أتذكره أكثر؟

Although high flexion PS prosthesis significantly increased flexion at 12 months compared to standard CR prosthesis, it had no significant effect on patient-perceived results, such as pain, satisfaction, "feel" of the knee, and ability to perform daily activities.

كيف سيؤثر ذلك على رعاية مرضاي؟

The findings suggest that increasing flexion beyond 110 degrees through high-flex PS prosthesis does not produce better patient related outcomes in this population. Further studies with larger sample sizes should be conducted to suggest the best prosthesis choice across different populations and activity levels.

تنويه

هذا المحتوى الموجود في هذه الصفحة هو لأغراض إعلامية فقط وليس الغرض منه أن يكون بديلاً عن المشورة الطبية المتخصصة أو التشخيص أو العلاج. إذا كنت بحاجة إلى علاج طبي، اطلب دائمًا مشورة طبيبك أو اذهب إلى أقرب قسم طوارئ إليك. الآراء والمعتقدات ووجهات النظر التي يعبر عنها الأفراد في المحتوى الموجود في هذه الصفحة لا تعكس آراء ومعتقدات ووجهات نظر أورثوإيفيدنس.

0 من 4 مقالات مجانية شهرية غير مقفلة
لقد وصلت إلى الحد الأقصى لمشاهدة 4 من 4 مقالات مجانية هذا الشهر

ادخل إلى OrthoEvidence مقابل 1.99 دولارًا أمريكيًا في الأسبوع.

ابق على اتصال بأحدث الأدلة. قم بالإلغاء في أي وقت.
  • تقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في مجال جراحة العظام
  • الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، والمقابلات مع الجراحين المعترف بهم دولياً، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
  • الاشتراك في نشرة The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك على اتخاذ قرارات سريرية أفضل
Upgrade
Close Dialog
أهلاً بعودتك!
هل نسيت كلمة المرور؟
ابدأ تجربتك المجانية اليوم!

سيكون حسابك تابعًا لـ
ويتضمن وصولًا مجانيًا إلى OrthoEvidence


أو
هل نسيت كلمة المرور؟

أو
يرجى التحقق من بريدك الإلكتروني

في حالة وجود حساب بعنوان البريد الإلكتروني المقدم، سيتم إرسال بريد إلكتروني لإعادة تعيين كلمة المرور إليك. إذا كنت لا ترى بريدًا إلكترونيًا، يرجى التحقق من مجلد الرسائل غير المرغوب فيها أو البريد غير المرغوب فيه.

لمزيد من المساعدة اتصل بفريق الدعم لدينا.

يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ترجمة تقرير ACE

تستخدم OrthoEvidence خدمة ترجمة من طرف ثالث لإتاحة المحتوى بلغات متعددة. يُرجى ملاحظة أنه على الرغم من بذل كل جهد ممكن لضمان الدقة، إلا أن الترجمات قد لا تكون دائمًا مثالية.

كيفية الاستشهاد بهذا ACE Report

OrthoEvidence. Higher flexion devices in TKA have no effect on patient-perceived outcomes. OE Journal. 2013;1(8):8. Available from: https://myorthoevidence.com/AceReport/Show/higher-flexion-devices-in-tka-have-no-effect-on-patient-perceived-outcomes

نسخ الاقتباس
يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ميزة العضو المميز

للوصول إلى هذه الميزة، يجب عليك تسجيل الدخول إلى حساب OrthoEvidence المميز.

شارك هذا ACE Report