Fracture reduction/guidewire-aiming device effective with IMN in femoral shaft fracture .
OrthoEvidence Journal (OE Journal) - ACE Report
OE Journal. 2016;4(21):20 PLoS One. 2016 Apr 26;11(4):e015433268 patients with femoral shaft fractures were randomized to receive either intramedullary nail (IMN) fixation with or without a fracture reduction and guidewire-aiming device. The purpose of this study was to determine if the use of a novel fracture reduction and guide wire aiming instrument was able to improve the operative efficiency of femoral fracture fixation. Findings indicated that a newly designed and manufactured instrument significantly improved the operative time, and decreased the frequency of wire drilling as well as the number of cases requiring open reduction when compared to IMN fixation without the device.
Was the allocation sequence adequately generated?
Was allocation adequately concealed?
Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?
Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?
Blinding Patients: Was knowledge of the allocated interventions adequately prevented?
Was loss to follow-up (missing outcome data) infrequent?
Are reports of the study free of suggestion of selective outcome reporting?
Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?
Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?
Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?
Sì = 1
Incerto = 0,5
Non rilevante = 0
No = 0
La valutazione dei criteri di segnalazione valuta la trasparenza con cui gli autori riportano le caratteristiche metodologiche e sperimentali dello studio all'interno della pubblicazione. La valutazione è suddivisa in cinque categorie che vengono presentate di seguito.
2/4
Aleatorización
2/4
Medición de resultados
4/4
Inclusión / exclusión
4/4
Descripción de la terapia
3/4
Estadísticas
Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65
L'Indice di Fragilità è uno strumento che aiuta l'interpretazione dei risultati significativi, fornendo una misura della forza di un risultato. L'Indice di Fragilità rappresenta il numero di eventi consecutivi che devono essere aggiunti a un risultato dicotomico per rendere il risultato non più significativo. Un numero piccolo rappresenta un risultato più debole, mentre un numero grande rappresenta un risultato più forte.
Perché questo studio era necessario ora?
The standard treatment of femoral shaft fractures consists of closed reduction and internal fixation with an interlocking intramedullary nail. However, closed reduction can pose a challenge in these fractures, and delays in reduction as well as the need to convert to open reduction impacts the operative time and surgical efficiency in the management of these injuries. Additionally, malreductiion at the fracture may make it difficult to determine the correct guide-wire entry point. While there are several technical tricks and reduction aids used, there has yet to be a device to ease the process of reduction and guide-wire introduction that has been evaluated in a randomized controlled manner. The present study was conducted to determine whether or not a newly manufactured reduction instrument was able to improve the efficiency of intramedullary nail fixation in femoral shaft fractures.
Qual era la domanda di ricerca principale?
In the treatment of femoral shaft fractures, does the use of a fracture reduction and guidewire-aiming device during intramedullary nail insertion improve intraoperative efficiency with respect to operative time, operative blood loss, the frequency of guidewire drilling, and the number of cases requiring conversion to open reduction compared to IMN fixation without the device?
- Significantly shorter operative time was reported in the IMN+device group compared to the control group (72.71 +/- 6.83 minutes vs. 81.47 +/- 6.11 minutes; p<0.01)
- Significantly lower frequency of starting guide-wire drilling was reported in the IMN+device group compared to the control group (1 vs. 3; p<0.001)
- Significantly lower number of open reduction cases were reported in the IMN+device group compared to the control group (0 vs. 4; p=0.042)
- No significant differences between IMN+device and control groups were reported for operative blood loss (102.65 +/- 16.75 mL vs. 109.21 +/- 17.81 mL, respectively; p=0.123) or duration of hospital stay (6.32 +/- 1.37 days vs. 6.41 +/- 1.4 days; p=0.794)
Che cosa devo ricordare di più?
In the treatment of femoral shaft fractures, intramedullary nail fixation with the assistance of a fracture reduction and guidewire-aiming device reported significantly improved operative time, the frequency of starting guide-wire drilling, and the number of cases requiring open reduction, in this small, single centre study. However, operative blood loss and duration of hospital stay were similar between groups.
Come influenzerà l'assistenza ai miei pazienti?
The results of this study suggest that the use of the novel fracture reduction and guidewire-aiming device to supplement intramedullary nail fixation may be effective in improving operative efficiency compared to intramedullary nail fixation alone. Further research with larger sample sizes and a stricter adherence to protocol is required for higher-quality evidence. Additionally, a multicenter study and an economic evaluation would provide important information with respect to learning curves, generalizability, and cost effectiveness of this novel device.
DISCLAIMER
Il contenuto di questa pagina è solo a scopo informativo e non intende sostituire la consulenza, la diagnosi o il trattamento medico professionale. Se ha bisogno di cure mediche, si rivolga sempre al suo medico o al pronto soccorso più vicino. Le opinioni, le convinzioni e i punti di vista espressi dalle persone sui contenuti presenti in questa pagina non riflettono le opinioni, le convinzioni e i punti di vista di OrthoEvidence.