TRAUMA

Improve the Efficiency of Surgery for Femoral Shaft Fractures with A Novel Instrument: A Randomized Controlled Trial

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2016;4(21):20 PLoS One. 2016 Apr 26;11(4):e0154332

Autores colaboradores

H Xu W Yin P Hsu H Qin Z An C Zhang J Sheng

68 patients with femoral shaft fractures were randomized to receive either intramedullary nail (IMN) fixation with or without a fracture reduction and guidewire-aiming device. The purpose of this study was to determine if the use of a novel fracture reduction and guide wire aiming instrument was able to improve the operative efficiency of femoral fracture fixation. Findings indicated that a newly designed and manufactured instrument significantly improved the operative time, and decreased the frequency of wire drilling as well as the number of cases requiring open reduction when compared to IMN fixation without the device.


Detalles de la financiación de la publicación +
Financiación:
Non-Industry funded
Patrocinador:
Shanghai Municipal Commission of Health and Family Planning
Conflictos:
None disclosed

Riesgo de sesgo

5/10

Criterios de información

15/20

Índice de fragilidad

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sí = 1

Incierto = 0,5

No relevante = 0

No = 0

La evaluación de los criterios de información evalúa la transparencia con la que los autores informan de las características metodológicas y del ensayo dentro de la publicación. La evaluación se divide en cinco categorías que se presentan a continuación.

2/4

Randomization

2/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

3/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

El Índice de Fragilidad es una herramienta que ayuda en la interpretación de hallazgos significativos, proporcionando una medida de fuerza para un resultado. El Índice de Fragilidad representa el número de eventos consecutivos que es necesario añadir a un resultado dicotómico para que el hallazgo deje de ser significativo. Un número pequeño representa un hallazgo más débil y un número grande un hallazgo más fuerte.

¿Por qué se necesitaba ahora este estudio?

The standard treatment of femoral shaft fractures consists of closed reduction and internal fixation with an interlocking intramedullary nail. However, closed reduction can pose a challenge in these fractures, and delays in reduction as well as the need to convert to open reduction impacts the operative time and surgical efficiency in the management of these injuries. Additionally, malreductiion at the fracture may make it difficult to determine the correct guide-wire entry point. While there are several technical tricks and reduction aids used, there has yet to be a device to ease the process of reduction and guide-wire introduction that has been evaluated in a randomized controlled manner. The present study was conducted to determine whether or not a newly manufactured reduction instrument was able to improve the efficiency of intramedullary nail fixation in femoral shaft fractures.

¿Cuál era la pregunta principal de la investigación?

In the treatment of femoral shaft fractures, does the use of a fracture reduction and guidewire-aiming device during intramedullary nail insertion improve intraoperative efficiency with respect to operative time, operative blood loss, the frequency of guidewire drilling, and the number of cases requiring conversion to open reduction compared to IMN fixation without the device?

Características del estudio +
Población:
68 patients, over 60 years of age, with a femoral shaft fracture, were included. Eligible patients had a unilateral, traumatic, closed fracture with complete displacement at the fracture site, with no or simple comminution (AO/OTA 32.A or 32.B fracture patterns), that underwent surgical treatment within 7 days of the injury. Open fractures, bilateral fractures, and/or pathological fractures were excluded.
Intervención:
IMN+device group: Patients underwent closed reduction and antegrade intramedullary nail fixation with the assistance of the fracture reduction and guidewire-aiming device. The fracture reduction device consists of 2 adjustable bone clamps (each with 2 independent tong arms that lock to each other once passed around the femoral shaft), 2 connectors and a long bar. Each clamp is placed percutaneously through a small lateral incision, with one clamp proximal and the other distal to the fracture site. The clamps are then linked to a long bar using connectors, which allow traction to be applied and alignment to be corrected in multiple planes. The guidewire-aiming device consists of a column, calibrated tube, slider and short sleeve. The column and slider are connected to the proximal bone clamp, which is subsequently connected to a calibrated bar and short sleeve. The calibrated bar and sleeve can be passed through and incision just proximal to the greater trochanter, and adjusted to have the sleeve coincide with the correct start point relative to the tip of the greater trochanter. This can then be locked into place to facilitate the starting guidewire placement. (n=34, 34 completed follow-up; Mean age: 37.32 +/- 8.40; 23M/11F)
Comparación:
Control group: Patients underwent closed reduction and antegrade intramedullary nail internal fixation without the novel fracture reduction and guide-wire aiming device. (n=34, 34 completed follow-up; Mean age: 35.12 +/- 9.34; 20M/14F)
Resultados:
Outcomes included operative time, operative blood loss, the frequency of guidewire drilling, the number of cases requiring open reduction, and hospital stay duration. The incidence of adverse events was also documented.
Métodos:
RCT
Tiempo:
Clinical and radiological outcomes were followed-up at 1 day, and 1, 3, 6, 9, and 12 months postoperatively.

¿Cuáles fueron los hallazgos importantes?

  • Significantly shorter operative time was reported in the IMN+device group compared to the control group (72.71 +/- 6.83 minutes vs. 81.47 +/- 6.11 minutes; p<0.01)
  • Significantly lower frequency of starting guide-wire drilling was reported in the IMN+device group compared to the control group (1 vs. 3; p<0.001)
  • Significantly lower number of open reduction cases were reported in the IMN+device group compared to the control group (0 vs. 4; p=0.042)
  • No significant differences between IMN+device and control groups were reported for operative blood loss (102.65 +/- 16.75 mL vs. 109.21 +/- 17.81 mL, respectively; p=0.123) or duration of hospital stay (6.32 +/- 1.37 days vs. 6.41 +/- 1.4 days; p=0.794)
¿Qué es lo que más debo recordar?

In the treatment of femoral shaft fractures, intramedullary nail fixation with the assistance of a fracture reduction and guidewire-aiming device reported significantly improved operative time, the frequency of starting guide-wire drilling, and the number of cases requiring open reduction, in this small, single centre study. However, operative blood loss and duration of hospital stay were similar between groups.

¿Cómo afectará esto al cuidado de mis pacientes?

The results of this study suggest that the use of the novel fracture reduction and guidewire-aiming device to supplement intramedullary nail fixation may be effective in improving operative efficiency compared to intramedullary nail fixation alone. Further research with larger sample sizes and a stricter adherence to protocol is required for higher-quality evidence. Additionally, a multicenter study and an economic evaluation would provide important information with respect to learning curves, generalizability, and cost effectiveness of this novel device.

DESCARGO DE RESPONSABILIDAD

El contenido de esta página tiene únicamente fines informativos y no pretende sustituir el consejo, diagnóstico o tratamiento médico profesional. Si necesita tratamiento médico, busque siempre el consejo de su médico o acuda al servicio de urgencias más cercano. Las opiniones, creencias y puntos de vista expresados por las personas sobre el contenido que se encuentra en esta página no reflejan las opiniones, creencias y puntos de vista de OrthoEvidence.

0 de 4 artículos mensuales GRATIS desbloqueados
Ha alcanzado su límite de vistas de 4 artículos gratuitos este mes

Acceda a OrtoEvidencia por tan sólo 1,99 $ a la semana.

Manténgase conectado con las últimas pruebas. Cancele en cualquier momento.
  • Valoraciones críticas de los últimos ensayos controlados aleatorizados de gran impacto y revisiones sistemáticas en ortopedia
  • Acceso al contenido del podcast OrthoEvidence, que incluye colaboraciones con el Journal of Bone and Joint Surgery, entrevistas con cirujanos reconocidos internacionalmente y mesas redondas sobre noticias y temas ortopédicos
  • Suscripción a The Pulse, un boletín quincenal basado en la evidencia y diseñado para ayudarle a tomar mejores decisiones clínicas
Upgrade
Close Dialog
Bienvenido
¿Ha olvidado su contraseña?
Comience hoy mismo su prueba GRATUITA

Su cuenta estará afiliada a
e incluye acceso gratuito a OrthoEvidence


O
¿Olvidó su contraseña?

O
Compruebe su correo electrónico

Si existe una cuenta con la dirección de correo electrónico proporcionada, se le enviará un correo electrónico para restablecer la contraseña. Si no ve el correo electrónico, compruebe su carpeta de correo no deseado o spam.

Si necesita más ayuda póngase en contacto con nuestro equipo de asistencia.

Inicie sesión para activar esta función

Para acceder a esta función, debe iniciar sesión en una cuenta activa de OrthoEvidence. Por favor, inicie sesión o cree una cuenta de prueba GRATUITA.

Traducir Informe ACE

OrthoEvidence utiliza un servicio de traducción de terceros para que el contenido sea accesible en varios idiomas. Tenga en cuenta que, aunque se hace todo lo posible para garantizar la exactitud, las traducciones no siempre son perfectas.

Cómo citar esto ACE Report

OrthoEvidence. Fracture reduction/guidewire-aiming device effective with IMN in femoral shaft fracture. OE Journal. 2016;4(21):20. Available from: https://myorthoevidence.com/AceReport/Show/fracture-reduction-guidewire-aiming-device-effective-with-imn-in-femoral-shaft-fracture

Copiar cita
Inicie sesión para activar esta función

Para acceder a esta función, debe iniciar sesión en una cuenta activa de OrthoEvidence. Por favor, inicie sesión o cree una cuenta de prueba GRATUITA.

Función de miembro Premium

Para acceder a esta función, debe iniciar sesión en una cuenta Premium de OrthoEvidence.

Compartir ACE Report