TRAUMA
Fewer ligament reconstruction failures with hinged external fixation for knee dislocations .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2014;2(9):29 J Bone Joint Surg Am. 2014 Feb 5;96(3):184-91. doi: 10.2106/JBJS.L.01603.
Autores contribuintes

JP Stannard CW Nuelle G McGwin DA Volgas

100 patients with a total of 103 knee dislocations were randomized to receive either a hinged knee brace or external fixation with a Compass Knee Hinge as part of a postoperative rehabilitation protocol. This study aimed to determine whether an external fixator would provide equivalent knee range of motion and improve failure rate in comparison to a hinged knee brace up to at least 1 year postoperatively. Results revealed significantly lower individual ligament reconstruction failure rates with the Compass Knee Hinge compared to hinged knee brace use. Lower knee reconstruction failure rates were also associated with the external fixator, but statistical significance was not achieved. Clinical outcome and knee range of motion statistics were similar between groups.


Detalhes do financiamento da publicação +
Financiamento:
Industry funded
Patrocinador:
Smith & Nephew
Conflitos:
None disclosed

Risco de viés

5/10

Critérios de notificação

14/20

Índice de Fragilidade

7

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sim = 1

Incerto = 0,5

Não relevante = 0

Não = 0

A Avaliação dos Critérios de Relato avalia a transparência com que os autores relatam as caraterísticas metodológicas e do ensaio na publicação. A avaliação está dividida em cinco categorias que são apresentadas de seguida.

4/4

Randomization

2/4

Outcome Measurements

2/4

Inclusion / Exclusion

2/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

O Índice de Fragilidade é uma ferramenta que auxilia na interpretação de achados significativos, fornecendo uma medida de força para um resultado. O Índice de Fragilidade representa o número de eventos consecutivos que precisam de ser adicionados a um resultado dicotómico para que o resultado deixe de ser significativo. Um número pequeno representa um resultado mais fraco e um número grande representa um resultado mais forte.

Porque é que este estudo era necessário agora?

Knee dislocation can result in multiple-ligament injuries and are commonly caused from blunt trauma. Rehabilitation protocols have typically been focused on achieving and maintaining ligamentous stability following surgery. However, it has been suggested that such postoperative practices may compromise the long-term clinical outcome and increase the risk of arthrofibrosis, and that early aggressive protocols may be more beneficial. As such, the Compass Universal Hinge external fixator, initially developed for the elbow, was modified for the knee (Compass Knee Hinge) to accommodate these protocols, allowing early motion without increased stress. Thus, this study aimed to determine the efficacy of this device.

Qual era a principal questão de investigação?

Does a Compass Knee Hinge external fixator provide comparable knee range of motion and result in fewer failures when compared to a control external hinge brace following ligament reconstruction after a minimum of 12 months?

Caraterísticas do estudo +
População:
100 patients with 103 knee dislocations (injuries to anterior cruciate ligament [ACL], and posterior cruciate ligament [PCL], posterolateral corner, and/or posteromedial corner) were randomized. Staged ligament reconstruction for the PCL, posterolateral corner, and posteromedial corner were performed 3-4 weeks following dislocation and ACL reconstructions were performed 6 weeks after initial surgery. Progressive postoperative protocols were followed in both groups. Patients received continuous passive motion machines and performed weight bearing as tolerated with the knee extended. Additionally, knee motion was progressively increased along with quadriceps and hamstring strengthening protocols.
Intervenção:
Compass Knee Hinge: At the index surgery, patients received placement of the Compass Knee Hinge. Fluoroscopy was first performed to locate the isometric point on the femur for placement of a centering wire. The hinge was then fixed using femoral and tibial external fixation pins with Rancho Cubes.. In the event of surgery involving repair or reconstruction of the posteromedial and/or posterolateral corner, the centering wire was placed prior to the repair or reconstruction. The hinge was mounted and femoral external fixation pins placed through the Rancho Cubes. The hinge was then detached until repair/reconstruction was completed, after which it was placed back on, and fixed with tibial pins. The device was kept on the knee until the scheduled ACL reconstruction (i.e. 6 weeks after). (n=45 with 47 dislocations)
Comparação:
Hinged knee brace: Patients were fitted with a hinged knee brace following operation. (n=55 with 56 dislocations)
Resultados:
Outcomes included knee motion, stability (0 no laxity, 1+: 1-5mm, 2+: 6-10mm, and 3+: >10mm), and visual analog scale pain score. A stable and clinically successful knee was defined as 0 or 1+ laxity during clinical examination, whereas a failure was defined as 2+ or 3+ laxity. For ACL and PCL, a failure was defined as a side-to-side difference of >3mm using a KT-2000 arthrometer (mm). Return to employment/recreational activity, Lysholm, International Knee Documentation Comittee (IKDC) objective and subjective scores, Short form-36 (SF-36), and condition of soft tissue surrounding the knee (per Tscherne and Gustilo score) were also recorded.
Métodos:
RCT, Prospective
Tempo:
Follow-ups were conducted at 2, 6, 12, 26, and 52 weeks for the first year, and then once annually thereafter.
Quais foram os resultados importantes?
  • 9 of 32 (28%) reconstructions failed with the control hinge knee brace versus 7 of 47 (15%) with the Compass Knee Hinge, a nonsignificant difference (p=0.15).
  • A significantly larger percentage of individual ligament reconstruction failed with the control hinge knee brace (22/105 [21%]) compared to the Compass Knee Hinge (11/157 [7%]) (p<0.001).
  • Mean Lysholm scores were similar between groups, with scores of 87.7 (range: 61-100) and 87.2 (69-100) in the control hinge knee brace and Compass Knee Hinge groups, respectively, up to 1 year postoperatively, and 90.1 and 89.9, respectively, up to 2 years postoperatively.
  • IKDC subjective scores did not significantly differ between the control hinge knee brace and Compass Knee Hinge groups at 24 months; mean scores were 56.8 and 49.5, respectively. Acceptable IKDC objective scores (normal and nearly normal knees) were achieved in 75% and 81% of the groups, respectively.
  • Mean VAS pain scores were similarly low between groups; 2.5 (range: 0-7) vs. 2.8 (0-8) for control hinge knee brace and Compass Knee Hinge, respectively.
  • 82% of control hinge knee brace patients returned to work at full duty, 9% at light duty, and 9% did not return by final follow-up. In the Compass Knee Hinge group, these values were 73%, 9%, and 18%.
  • Overall, knee range of motion was good in both groups at the final evaluation. Mean range of motion was from 1 to 132 deg in the control group, and 2 to 124 deg in the Compass Knee Hinge group.
De que é que me devo lembrar mais?

Patients who received a Compass Knee Hinge had a significantly lower individual ligament reconstruction failure rate compared to those who received an control hinge knee brace. Lysholm scores, IKDC subjective and objective scores, VAS pain scores, knee range of motion, and percentage of patients returning to work were similar between groups.

Como é que isto afectará o tratamento dos meus doentes?

The results indicated that progressive rehabilitation protocols can be achieved using a Compass Knee Hinge external fixator without compromising knee stability following knee reconstruction surgery. However, this device is expensive and takes time to apply, evoking a high learning curve and prolonging operation time. Future studies are warranted in larger populations to further investigate the efficacy of the Compass Knee Hinge.

AVISO LEGAL

O conteúdo desta página destina-se apenas a fins informativos e não pretende substituir o aconselhamento, diagnóstico ou tratamento médico profissional. Se necessitar de tratamento médico, procure sempre o conselho do seu médico ou dirija-se ao serviço de urgência mais próximo. As opiniões, crenças e pontos de vista expressos pelos indivíduos no conteúdo encontrado nesta página não reflectem as opiniões, crenças e pontos de vista da OrthoEvidence.

0 de 4 artigos mensais GRATUITOS desbloqueados
Atingiu o seu limite de 4 visualizações de artigos gratuitos este mês

Aceda à OrthoEvidence por apenas $1,99 por semana.

Mantenha-se ligado às últimas evidências. Cancele a qualquer altura.
  • Avaliações críticas dos mais recentes ensaios clínicos aleatórios de alto impacto e revisões sistemáticas em ortopedia
  • Acesso ao conteúdo do podcast OrthoEvidence, incluindo colaborações com o Journal of Bone and Joint Surgery, entrevistas com cirurgiões reconhecidos internacionalmente e discussões em mesa redonda sobre notícias e tópicos ortopédicos
  • Subscrição do The Pulse, um boletim informativo duas vezes por semana baseado em evidências, concebido para o ajudar a tomar melhores decisões clínicas
Upgrade
Close Dialog
Bem-vindo de volta!
Esqueceu-se da palavra-passe?
Comece hoje o seu teste GRATUITO!

A sua conta será afiliada a
e inclui acesso gratuito ao OrthoEvidence


OU
Esqueceu-se da palavra-passe?

OU
Verifique o seu e-mail

Se existir uma conta com o endereço de e-mail fornecido, ser-lhe-á enviado um e-mail de reposição da palavra-passe. Se não vir uma mensagem de correio eletrónico, verifique a sua pasta de spam ou de lixo eletrónico.

Para obter mais assistência, contacte a nossa equipa de apoio.

Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Traduzir o Relatório ACE

A OrthoEvidence utiliza um serviço de tradução de terceiros para tornar o conteúdo acessível em vários idiomas. Tenha em atenção que, embora sejam feitos todos os esforços para garantir a exatidão, as traduções podem nem sempre ser perfeitas.

Como citar isto ACE Report

OrthoEvidence. Fewer ligament reconstruction failures with hinged external fixation for knee dislocations. OE Journal. 2014;2(9):29. Available from: https://myorthoevidence.com/AceReport/Show/fewer-ligament-reconstruction-failures-with-hinged-external-fixation-for-knee-dislocations

Copie a citação
Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Funcionalidade de Membro Premium

Para aceder a esta funcionalidade, tem de ter sessão iniciada numa conta Premium da OrthoEvidence.

Partilhe isto ACE Report