EFORT: QUADRA vs. AMIStem femoral components for THA .
Periprosthetic Bone Mineral Density After Total Hip Arthroplasty With An AMIStem Or Quadra Femoral Component Performed By A Minimally Invasive Anterior Approach (AMIS): A Prospective Randomised Clinical Dualenergy X-Ray Absorptiometry Study.
40 patients scheduled for total hip arthroplasty (THA) were randomly assigned into 1 of 2 groups to test two different stem designs; QUADRA and AMIS. The results of the study indicated that both stem designs significantly improved clinical scores (HHS and HAAS) by final follow up, and revealed no significant difference between them regarding clinical outcomes at any time point. Bone mineral density (BMD) analysis demonstrated a slight reduction in bone density after 1 year in both groups, specifically within Gruen Zone 7.
Vollständigen ACE-Bericht freischalten
Sie haben Zugang zu 4 weiteren KOSTENLOSEN Artikeln in diesem Monat.
Klicken Sie unten, um diese ACE Reports freizuschalten und anzusehen
Jetzt freischalten
Kritische Beurteilungen der neuesten, hochwirksamen randomisierten kontrollierten Studien und systematischen Übersichten in der Orthopädie
Zugang zu OrthoEvidence-Podcast-Inhalten, einschließlich Kooperationen mit dem Journal of Bone and Joint Surgery, Interviews mit international anerkannten Chirurgen und Diskussionsrunden zu orthopädischen Neuigkeiten und Themen
Abonnement von The Pulse, einem zweimal wöchentlich erscheinenden evidenzbasierten Newsletter, der Ihnen helfen soll, bessere klinische Entscheidungen zu treffen
Exklusiver Zugang zu Originalartikeln, einschließlich eigener systematischer Übersichten, sowie zu Artikeln über Methoden der Gesundheitsforschung und aktuelle orthopädische Themen