ARTHROPLASTY
Coatings for femoral stems .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(2):23 Acta Orthop. 2011 Jun;82(3):308-14. Epub 2011 Apr 19

50 arthritic patients undergoing total hip arthroplasty were randomized to receive either distally tapered, extended coated stems, or straight proximally coated stems, to study potential differences in implant migration. At 2 years post-surgery, radiostereometric analysis revealed that both stem types demonstrated large amounts of implant migration, with no significant differences between groups.


Detalhes do financiamento da publicação +
Financiamento:
Industry funded
Patrocinador:
Zimmer, Warsaw, IN.
Conflitos:
None disclosed

Risco de viés

6,5/10

Critérios de notificação

19/20

Índice de Fragilidade

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Sim = 1

Incerto = 0,5

Não relevante = 0

Não = 0

A Avaliação dos Critérios de Relato avalia a transparência com que os autores relatam as caraterísticas metodológicas e do ensaio na publicação. A avaliação está dividida em cinco categorias que são apresentadas de seguida.

4/4

Randomization

3/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

O Índice de Fragilidade é uma ferramenta que auxilia na interpretação de achados significativos, fornecendo uma medida de força para um resultado. O Índice de Fragilidade representa o número de eventos consecutivos que precisam de ser adicionados a um resultado dicotómico para que o resultado deixe de ser significativo. Um número pequeno representa um resultado mais fraco e um número grande representa um resultado mais forte.

Porque é que este estudo era necessário agora?

The varying types of femoral stem coatings used for total hip arthroplasty have been investigated in studies to determine implant migration and rotation. This study aims to further investigate the outcomes with respect to extended coating versus proximal coating.

Qual era a principal questão de investigação?

Does an extended coated stem lead to reduced implant migration two years postoperatively, when compared to a proximally coated stem in patients undergoing total hip arthroplasty for primary osteoarthritis?

Caraterísticas do estudo +
População:
50 patients with a median age of 60 undergoing total hip arthroplasty for primary hip osteoarthritis.
Intervenção:
Distally tapered, extended coated stem (VerSys Fiber Metal Taper Hip Prosthesis) (n=20)
Comparação:
Straight, proximally coated stem (VerSys Fiber Metal MidCoat Hip Prosthesis) (n=21)
Resultados:
Radiostereometric analysis
Métodos:
RCT; Single-centered
Tempo:
24 month follow-up
Quais foram os resultados importantes?
  • no statistically significant difference during RSA assessment with respect to rotation or translation detected between groups at any of the follow-up points
  • implant migration of both groups was significant from initial postoperative measurements
De que é que me devo lembrar mais?

Both implant stem groups demonstrated significant migration in comparison to baseline measures; however, no statistically significant difference was detected between the groups. The authors recommend that additional follow-ups are required in future trials.

Como é que isto afectará o tratamento dos meus doentes?

Both implants demonstrate significant migration,which warrants further investigation; however, this trial was unable to conclude which coating is superior. Additionally, the authors cite this study as an evidence for the necessity of RSA, as standard protocol to monitor all new implants.

AVISO LEGAL

O conteúdo desta página destina-se apenas a fins informativos e não pretende substituir o aconselhamento, diagnóstico ou tratamento médico profissional. Se necessitar de tratamento médico, procure sempre o conselho do seu médico ou dirija-se ao serviço de urgência mais próximo. As opiniões, crenças e pontos de vista expressos pelos indivíduos no conteúdo encontrado nesta página não reflectem as opiniões, crenças e pontos de vista da OrthoEvidence.

0 de 4 artigos mensais GRATUITOS desbloqueados
Atingiu o seu limite de 4 visualizações de artigos gratuitos este mês

Aceda à OrthoEvidence por apenas $1,99 por semana.

Mantenha-se ligado às últimas evidências. Cancele a qualquer altura.
  • Avaliações críticas dos mais recentes ensaios clínicos aleatórios de alto impacto e revisões sistemáticas em ortopedia
  • Acesso ao conteúdo do podcast OrthoEvidence, incluindo colaborações com o Journal of Bone and Joint Surgery, entrevistas com cirurgiões reconhecidos internacionalmente e discussões em mesa redonda sobre notícias e tópicos ortopédicos
  • Subscrição do The Pulse, um boletim informativo duas vezes por semana baseado em evidências, concebido para o ajudar a tomar melhores decisões clínicas
Upgrade
Close Dialog
Bem-vindo de volta!
Esqueceu-se da palavra-passe?
Comece hoje o seu teste GRATUITO!

A sua conta será afiliada a
e inclui acesso gratuito ao OrthoEvidence


OU
Esqueceu-se da palavra-passe?

OU
Verifique o seu e-mail

Se existir uma conta com o endereço de e-mail fornecido, ser-lhe-á enviado um e-mail de reposição da palavra-passe. Se não vir uma mensagem de correio eletrónico, verifique a sua pasta de spam ou de lixo eletrónico.

Para obter mais assistência, contacte a nossa equipa de apoio.

Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Traduzir o Relatório ACE

A OrthoEvidence utiliza um serviço de tradução de terceiros para tornar o conteúdo acessível em vários idiomas. Tenha em atenção que, embora sejam feitos todos os esforços para garantir a exatidão, as traduções podem nem sempre ser perfeitas.

Como citar isto ACE Report

OrthoEvidence. Coatings for femoral stems. OE Journal. 2013;1(2):23. Available from: https://myorthoevidence.com/AceReport/Show/coatings-for-femoral-stems

Copie a citação
Inicie sessão para ativar esta funcionalidade

Para aceder a esta funcionalidade, tem de iniciar sessão numa conta OrthoEvidence ativa. Inicie a sessão ou crie uma conta de avaliação GRATUITA.

Funcionalidade de Membro Premium

Para aceder a esta funcionalidade, tem de ter sessão iniciada numa conta Premium da OrthoEvidence.

Partilhe isto ACE Report