ARTHROPLASTY
Coatings for femoral stems .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(2):23 Acta Orthop. 2011 Jun;82(3):308-14. Epub 2011 Apr 19
المؤلفون المساهمون

T Baad-Hansen S Kold N Olsen F Christensen K Soballe

50 arthritic patients undergoing total hip arthroplasty were randomized to receive either distally tapered, extended coated stems, or straight proximally coated stems, to study potential differences in implant migration. At 2 years post-surgery, radiostereometric analysis revealed that both stem types demonstrated large amounts of implant migration, with no significant differences between groups.


تفاصيل تمويل المنشور +
التمويل:
Industry funded
الراعي:
Zimmer, Warsaw, IN.
Conflicts:
None disclosed

مخاطر التحيز

6٫5/10

معايير الإبلاغ

19/20

مؤشر الهشاشة

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

نعم = 1

غير مؤكد = 0.5

غير ذي صلة = 0

لا = 0

يقيّم تقييم معايير الإبلاغ الشفافية التي يبلغ بها المؤلفون عن الخصائص المنهجية والتجريبية للتجربة في المنشور. ينقسم التقييم إلى خمس فئات معروضة أدناه.

4/4

Randomization

3/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

مؤشر الهشاشة هو أداة تساعد في تفسير النتائج المهمة، وتوفر مقياسًا لقوة النتيجة. ويمثل مؤشر الهشاشة عدد الأحداث المتتالية التي يجب إضافتها إلى نتيجة ثنائية التفرع لجعل النتيجة غير مهمة. يمثل الرقم الصغير نتيجة أضعف ويمثل الرقم الكبير نتيجة أقوى.

لماذا كانت هناك حاجة لهذه الدراسة الآن؟

The varying types of femoral stem coatings used for total hip arthroplasty have been investigated in studies to determine implant migration and rotation. This study aims to further investigate the outcomes with respect to extended coating versus proximal coating.

ما هو سؤال البحث الرئيسي؟

Does an extended coated stem lead to reduced implant migration two years postoperatively, when compared to a proximally coated stem in patients undergoing total hip arthroplasty for primary osteoarthritis?

خصائص الدراسة +
Population:
50 patients with a median age of 60 undergoing total hip arthroplasty for primary hip osteoarthritis.
Intervention:
Distally tapered, extended coated stem (VerSys Fiber Metal Taper Hip Prosthesis) (n=20)
Comparison:
Straight, proximally coated stem (VerSys Fiber Metal MidCoat Hip Prosthesis) (n=21)
Outcomes:
Radiostereometric analysis
Methods:
RCT; Single-centered
Time:
24 month follow-up
ما هي النتائج المهمة؟
  • no statistically significant difference during RSA assessment with respect to rotation or translation detected between groups at any of the follow-up points
  • implant migration of both groups was significant from initial postoperative measurements
ما الذي يجب أن أتذكره أكثر؟

Both implant stem groups demonstrated significant migration in comparison to baseline measures; however, no statistically significant difference was detected between the groups. The authors recommend that additional follow-ups are required in future trials.

كيف سيؤثر ذلك على رعاية مرضاي؟

Both implants demonstrate significant migration,which warrants further investigation; however, this trial was unable to conclude which coating is superior. Additionally, the authors cite this study as an evidence for the necessity of RSA, as standard protocol to monitor all new implants.

تنويه

هذا المحتوى الموجود في هذه الصفحة هو لأغراض إعلامية فقط وليس الغرض منه أن يكون بديلاً عن المشورة الطبية المتخصصة أو التشخيص أو العلاج. إذا كنت بحاجة إلى علاج طبي، اطلب دائمًا مشورة طبيبك أو اذهب إلى أقرب قسم طوارئ إليك. الآراء والمعتقدات ووجهات النظر التي يعبر عنها الأفراد في المحتوى الموجود في هذه الصفحة لا تعكس آراء ومعتقدات ووجهات نظر أورثوإيفيدنس.

0 من 4 مقالات مجانية شهرية غير مقفلة
لقد وصلت إلى الحد الأقصى لمشاهدة 4 من 4 مقالات مجانية هذا الشهر

ادخل إلى OrthoEvidence مقابل 1.99 دولارًا أمريكيًا في الأسبوع.

ابق على اتصال بأحدث الأدلة. قم بالإلغاء في أي وقت.
  • تقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في مجال جراحة العظام
  • الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، والمقابلات مع الجراحين المعترف بهم دولياً، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
  • الاشتراك في نشرة The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك على اتخاذ قرارات سريرية أفضل
Upgrade
أهلاً بعودتك!
هل نسيت كلمة المرور؟
ابدأ تجربتك المجانية اليوم!

سيكون حسابك تابعًا لـ
ويتضمن وصولًا مجانيًا إلى OrthoEvidence


أو
هل نسيت كلمة المرور؟

أو
يرجى التحقق من بريدك الإلكتروني

في حالة وجود حساب بعنوان البريد الإلكتروني المقدم، سيتم إرسال بريد إلكتروني لإعادة تعيين كلمة المرور إليك. إذا كنت لا ترى بريدًا إلكترونيًا، يرجى التحقق من مجلد الرسائل غير المرغوب فيها أو البريد غير المرغوب فيه.

لمزيد من المساعدة اتصل بفريق الدعم لدينا.

يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ترجمة تقرير ACE

تستخدم OrthoEvidence خدمة ترجمة من طرف ثالث لإتاحة المحتوى بلغات متعددة. يُرجى ملاحظة أنه على الرغم من بذل كل جهد ممكن لضمان الدقة، إلا أن الترجمات قد لا تكون دائمًا مثالية.

كيفية الاستشهاد بهذا ACE Report

OrthoEvidence. Coatings for femoral stems. OE Journal. 2013;1(2):23. Available from: https://myorthoevidence.com/AceReport/Show/coatings-for-femoral-stems

نسخ الاقتباس
يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ميزة العضو المميز

للوصول إلى هذه الميزة، يجب عليك تسجيل الدخول إلى حساب OrthoEvidence المميز.

شارك هذا ACE Report