ACE Report Cover
Bone loss seen in medium-term with both customized femoral and uncemented anatomical stem
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
اللغة
Download Download Download
تحميل
Cite this Report Cite this Report Cite this Report
اقتباس
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ المفضلة
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
اللغة
Download Download Download
تحميل
Cite this Report Cite this Report Cite this Report
اقتباس
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ المفضلة
ARTHROPLASTY
Bone loss seen in medium-term with both customized femoral and uncemented anatomical stem .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(2):20 Acta Orthop. 2011 Aug;82(4):410-6. Epub 2011 Jun 14
المؤلفون المساهمون

M Nysted P Benum J Klaksvik O Foss A Aamodt

87 patients were randomized to undergo hip arthroplasty with an uncemented customized unique femoral stem or a uncemented ABG-I anatomical stem. The primary outcome examined was periprosthetic bone loss (change in bone mineral density), measured by Dual-energy X-ray absorptiometry (DXA) from baseline to the follow-up. The results indicated loss in bone mineral density for both customized femoral and uncemented anatomical stem at the 5-year (medium-term) follow-up.


تفاصيل تمويل المنشور +
التمويل:
Not Reported
التعارضات:
None disclosed

مخاطر التحيز

4٫5/10

معايير الإبلاغ

18/20

مؤشر الهشاشة

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

نعم = 1

غير مؤكد = 0.5

غير ذي صلة = 0

لا = 0

يقيّم تقييم معايير الإبلاغ الشفافية التي يبلغ بها المؤلفون عن الخصائص المنهجية والتجريبية للتجربة في المنشور. ينقسم التقييم إلى خمس فئات معروضة أدناه.

4/4

Randomization

3/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

3/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

مؤشر الهشاشة هو أداة تساعد في تفسير النتائج المهمة، وتوفر مقياسًا لقوة النتيجة. ويمثل مؤشر الهشاشة عدد الأحداث المتتالية التي يجب إضافتها إلى نتيجة ثنائية التفرع لجعل النتيجة غير مهمة. يمثل الرقم الصغير نتيجة أضعف ويمثل الرقم الكبير نتيجة أقوى.

لماذا كانت هناك حاجة لهذه الدراسة الآن؟

Implantation of a prosthesis can change the load distribution of the host bone. Customized femoral stems are, therefore, specifically designed to provide optimal physiological load transfer and minimize stress shielding. This study examines the outcomes in periprosthetic bone loss using DXA in hip arthroplasties implementing an uncemented customized femoral stem and an uncemented anatomical stem.

ما هو سؤال البحث الرئيسي؟

What are the outcomes in periprosthetic bone loss (change in bone density),when undergoing hip arthroplasty with an uncemented customized unique femoral stem, compared to an uncemented anatomical ABG-I stem in patients with primary or secondary osteoarthritis at 5 years?

خصائص الدراسة +
Population:
87 patients with primary or secondary osteoarthritis (Age <65 years)
Intervention:
Uncemented Unique customized femoral stem made of titanium alloy and hydroxyapatite coating (SCP, Trondheim, Norway) (Mean age: 55 (36-65) years) (n=47)
Comparison:
Uncemented anatomical ABG-I stem made of titanium alloy and hydroxyapatite coating (Stryker-Howmedica, Allendale, NJ) (Mean age: 53 (21-65) years) (n=41)
Outcomes:
Bone mineral density (Periprosthetic bone loss) at the 7 Gruen zones in the proximal femur, measured by Dual-energy X-ray absorptiometry (DXA).
Methods:
RCT
Time:
5 years (Assessment at 3, 6, 12, 24, 36, and 60 months)
ما هي النتائج المهمة؟
  • The proximal Gruen zones showed the greatest degree of bone loss in both the anatomical ABG-I stem group and the customized Unique stem group.
  • There was a statistically significant difference in bone mineral density (BMD) reduction at Gruen zone 4 between the two groups. The ABG-I group had at 1.6% reduction in BMD compared to a 9.7% reduction in the Unique group (p=0.003)
  • The ABG-I group had at 15% reduction in BMD at zone 1, compared to a 14% reduction in the Unique group. At zone 7, the ABG-I group had at 28% reduction reduction in BMD compared to a 27% reduction in the Unique group.
  • The Unique group showed significant differences in BMD in Gruen zones 1, 2, 3, 4, and 7 when compared to baseline (p<0.001). The ABG-I group showed significant differences in BMD in Gruen zones 1, 2, 6, and 7 when compared to baseline (p<0.001).
  • No patients required hip revision surgery at the 5-year follow-up, but 5 patients reported complications. The ABG-I group had 2 patients with an early dislocation, 1 patient developed a deep venous thrombosis, and 1 patient had an episode of subluxation. 1 patient from the Unique group had an intraoperative injury of the common peroneal nerve.
ما الذي يجب أن أتذكره أكثر؟

Both the anatomical and customized stems had proximal bone loss at the 5-year follow-up - this was unavoidable due to stress-shielding.

كيف سيؤثر ذلك على رعاية مرضاي؟

There is still uncertainty regarding the clinical consequences of proximal bone loss around uncemented stems in the medium- and long-term . Further research is needed to better define the effects of proximal bone loss following total hip arthroplasty.

تنويه

هذا المحتوى الموجود في هذه الصفحة هو لأغراض إعلامية فقط وليس الغرض منه أن يكون بديلاً عن المشورة الطبية المتخصصة أو التشخيص أو العلاج. إذا كنت بحاجة إلى علاج طبي، اطلب دائمًا مشورة طبيبك أو اذهب إلى أقرب قسم طوارئ إليك. الآراء والمعتقدات ووجهات النظر التي يعبر عنها الأفراد في المحتوى الموجود في هذه الصفحة لا تعكس آراء ومعتقدات ووجهات نظر أورثوإيفيدنس.

0 من 4 مقالات مجانية شهرية غير مقفلة
لقد وصلت إلى الحد الأقصى لمشاهدة 4 من 4 مقالات مجانية هذا الشهر

ادخل إلى OrthoEvidence مقابل 1.99 دولارًا أمريكيًا في الأسبوع.

ابق على اتصال بأحدث الأدلة. قم بالإلغاء في أي وقت.
  • تقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في مجال جراحة العظام
  • الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، والمقابلات مع الجراحين المعترف بهم دولياً، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
  • الاشتراك في نشرة The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك على اتخاذ قرارات سريرية أفضل
Upgrade
Close Dialog
أهلاً بعودتك!
هل نسيت كلمة المرور؟
ابدأ تجربتك المجانية اليوم!

سيكون حسابك تابعًا لـ
ويتضمن وصولًا مجانيًا إلى OrthoEvidence


أو
هل نسيت كلمة المرور؟

أو
يرجى التحقق من بريدك الإلكتروني

في حالة وجود حساب بعنوان البريد الإلكتروني المقدم، سيتم إرسال بريد إلكتروني لإعادة تعيين كلمة المرور إليك. إذا كنت لا ترى بريدًا إلكترونيًا، يرجى التحقق من مجلد الرسائل غير المرغوب فيها أو البريد غير المرغوب فيه.

لمزيد من المساعدة اتصل بفريق الدعم لدينا.

يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ترجمة تقرير ACE

تستخدم OrthoEvidence خدمة ترجمة من طرف ثالث لإتاحة المحتوى بلغات متعددة. يُرجى ملاحظة أنه على الرغم من بذل كل جهد ممكن لضمان الدقة، إلا أن الترجمات قد لا تكون دائمًا مثالية.

كيفية الاستشهاد بهذا ACE Report

OrthoEvidence. Bone loss seen in medium-term with both customized femoral and uncemented anatomical stem. OE Journal. 2013;1(2):20. Available from: https://myorthoevidence.com/AceReport/Show/bone-loss-seen-in-medium-term-with-both-customized-femoral-and-uncemented-anatomical-stem