Assessing TKA component position accuracy when implanted with PSI versus conventional instruments .
This report has been verified
by one or more authors of the
original publication.
Three-dimensional analysis of accuracy of component positioning in total knee arthroplasty with patient specific and conventional instruments: A randomized controlled trial
Knee. 2017 Dec;24(6):1469-147752 patients scheduled for total knee arthroplasty were randomized to have the procedure completed using patient-specific instrumentation or conventional intramedullary and extramedullary instruments. Patients were assessed postoperatively on CT for deviation from the planned component orientation in the coronal, sagittal, and axial planes. Results demonstrated a significantly smaller deviation in coronal femoral component position in the PSI group compared to the conventional group, but also a significantly higher deviation in tibial component slope.