ACE Report Cover
Smaller migration with monoblock versus modular tibial component in uncemented TKA
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
اللغة
Download Download Download
تحميل
Cite this Report Cite this Report Cite this Report
اقتباس
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ المفضلة
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
اللغة
Download Download Download
تحميل
Cite this Report Cite this Report Cite this Report
اقتباس
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ المفضلة
ARTHROPLASTY
Smaller migration with monoblock versus modular tibial component in uncemented TKA .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2017;5(15):5 Acta Orthop. 2016 Dec;87(6):607-614
المؤلفون المساهمون

MM Petersen G Flivik T Lind N Winther H Schrøder MR Andersen

67 patients scheduled for total knee arthroplasty were randomized to receive either a monoblock or modular tibial component. Patients were assessed for component migration over the first 24 months postoperatively, as well as clinical scores in the same time frame. Results demonstrated significantly lower maximum total point motion in the monoblock group compared to the modular group after 24 months. As well, single dimension migration demonstrated significantly lower subsidence in the monoblock group compared to the modular group. Clinical scores did not significantly differ between groups.


تفاصيل تمويل المنشور +
التمويل:
Industry funded
الراعي:
Zimmer; Gentofte Hospital, Copenhagen (non-industry)
Conflicts:
None disclosed

مخاطر التحيز

5٫5/10

معايير الإبلاغ

16/20

مؤشر الهشاشة

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

نعم = 1

غير مؤكد = 0.5

غير ذي صلة = 0

لا = 0

يقيّم تقييم معايير الإبلاغ الشفافية التي يبلغ بها المؤلفون عن الخصائص المنهجية والتجريبية للتجربة في المنشور. ينقسم التقييم إلى خمس فئات معروضة أدناه.

4/4

Randomization

3/4

Outcome Measurements

3/4

Inclusion / Exclusion

2/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

مؤشر الهشاشة هو أداة تساعد في تفسير النتائج المهمة، وتوفر مقياسًا لقوة النتيجة. ويمثل مؤشر الهشاشة عدد الأحداث المتتالية التي يجب إضافتها إلى نتيجة ثنائية التفرع لجعل النتيجة غير مهمة. يمثل الرقم الصغير نتيجة أضعف ويمثل الرقم الكبير نتيجة أقوى.

لماذا كانت هناك حاجة لهذه الدراسة الآن؟

Aseptic loosening of tibial components remains a primary concern regarding the overall survivorship of total knee arthroplasty implants. Polyethylene wear has been identified as a potential contributor to aseptic loosening. Recently, there has been debate whether tibial component designs, specifically monoblock versus modular polyethylene components, may differ in their respective wear and migration profiles.

ما هو سؤال البحث الرئيسي؟

In total knee arthroplasty, does the use of a monoblock tibial component result in significantly lower component migration within the first 2 years postoperatively when compared to a modular polyethylene component?

خصائص الدراسة +
Population:
67 patients, under the age of 70, scheduled for total knee arthroplasty due to osteoarthritis were included. All cases were performed using an uncemented, cruciate-retaining NexGen total knee system (Zimmer) with a cemented, all-poly patellar component.
Intervention:
Monoblock group: Patients received the monoblock NexGen Trabecular Metal technology tibial component. Tantalum markers were inserted in the tibial bone and polyethylene portion of the tibial component to facilitate radiostereometric analysis (RSA) during follow-up. (33 randomized; 26 analyzed) (Mean age: 62 [47-70])
Comparison:
Modular group: Patients received the modular NexGen Trabecular Metal technology tibial component. Tantalum markers were inserted in the tibial bone and polyethylene portion of the tibial component to facilitate RSA during follow-up. (n=34 randomized; 27 analyzed) (Mean age: 61 [44-70])
Outcomes:
The primary outcome was tibial component migration measured via maximum total point motion on RSA. Secondary outcomes included tibial component translation and rotation individually in the x-, y- and z-axes, and clinical outcome via the Knee Society Score and EuroQoL 5-dimension questionnaire (EQ-5D).
Methods:
RCT
Time:
Follow-up was scheduled for 3, 6, 12, and 24 months postoperatively.
ما هي النتائج المهمة؟
  • There was no significant difference in MTPM between the monoblock group and the modular group after 3 months (0.58mm [95%CI 0.43-0.72] vs. 0.85mm [0.65-1.09]; p=0.2) or 6 months (0.66mm [0.44-0.77] vs. 0.98mm [0.74-1.26];p=0.1); MTPM was significantly lower in the monoblock group compared to the modular group at 12 months (0.65mm [0.46-0.78] vs. 1.01mm [0.81-1.28]; p=0.02) and 24 months (0.72mm [0.53-0.82 vs. 1.15mm [0.90-1.37]; p=0.02).
  • In individual axes for translation, no significant differences between groups in anterior-posterior translation or lateral-medial translation of the tibial component were noted at any follow-up. In contrast, beginning at 6 months, significantly smaller superior-inferior translation of the tibial component was observed in the monoblock group compared to the modular group, and significance was maintained after 24 months (-0.18mm [-0.24, -0.07] vs. -0.38mm [-0.54, -0.23]; p=0.02).
  • In individual axes for rotation, no significant differences between groups were observed in either anterior-posterior tilt, varus-valgus tilt, or internal-external rotation of the component at any follow-up time point (all p>0.05).
  • No significant differences between groups were observed in Knee Society Knee scores, Knee Society Function scores, or EQ-5D scores at any follow-up time point (all p>0.05).
ما الذي يجب أن أتذكره أكثر؟

In uncemented total knee arthroplasty, the use of a monoblock tibial component was associated with significantly smaller maximum total point motion after 24 months, and, specifically, significantly lower superior-inferior translation of the tibial component after 24 months when compared to a modular polyethylene tibial component. No significant between-group differences were noted in x- and z-axis translation of the component, x-, y, and z-axis rotation of the component, or clinical scores after 24 months.

كيف سيؤثر ذلك على رعاية مرضاي؟

The results of this study suggest that monoblock tibial components may result in a statistically significantly smaller degree of migration, as assessed via maximum total point motion, from 12 to 24 months after uncemented total knee arthroplasty when compared to modular polyethylene tibial components. Nonetheless, there did not appear to be any clinical impact of the difference observed between groups within this time frame. Follow-up studies are needed to determine if the observed difference in migration has any implication on the incidence of aseptic loosening and component survivorship in the long-term.

تنويه

هذا المحتوى الموجود في هذه الصفحة هو لأغراض إعلامية فقط وليس الغرض منه أن يكون بديلاً عن المشورة الطبية المتخصصة أو التشخيص أو العلاج. إذا كنت بحاجة إلى علاج طبي، اطلب دائمًا مشورة طبيبك أو اذهب إلى أقرب قسم طوارئ إليك. الآراء والمعتقدات ووجهات النظر التي يعبر عنها الأفراد في المحتوى الموجود في هذه الصفحة لا تعكس آراء ومعتقدات ووجهات نظر أورثوإيفيدنس.

0 من 4 مقالات مجانية شهرية غير مقفلة
لقد وصلت إلى الحد الأقصى لمشاهدة 4 من 4 مقالات مجانية هذا الشهر

ادخل إلى OrthoEvidence مقابل 1.99 دولارًا أمريكيًا في الأسبوع.

ابق على اتصال بأحدث الأدلة. قم بالإلغاء في أي وقت.
  • تقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في مجال جراحة العظام
  • الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، والمقابلات مع الجراحين المعترف بهم دولياً، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
  • الاشتراك في نشرة The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك على اتخاذ قرارات سريرية أفضل
Upgrade
أهلاً بعودتك!
هل نسيت كلمة المرور؟
ابدأ تجربتك المجانية اليوم!

سيكون حسابك تابعًا لـ
ويتضمن وصولًا مجانيًا إلى OrthoEvidence


أو
هل نسيت كلمة المرور؟

أو
يرجى التحقق من بريدك الإلكتروني

في حالة وجود حساب بعنوان البريد الإلكتروني المقدم، سيتم إرسال بريد إلكتروني لإعادة تعيين كلمة المرور إليك. إذا كنت لا ترى بريدًا إلكترونيًا، يرجى التحقق من مجلد الرسائل غير المرغوب فيها أو البريد غير المرغوب فيه.

لمزيد من المساعدة اتصل بفريق الدعم لدينا.

يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ترجمة تقرير ACE

تستخدم OrthoEvidence خدمة ترجمة من طرف ثالث لإتاحة المحتوى بلغات متعددة. يُرجى ملاحظة أنه على الرغم من بذل كل جهد ممكن لضمان الدقة، إلا أن الترجمات قد لا تكون دائمًا مثالية.

كيفية الاستشهاد بهذا ACE Report

OrthoEvidence. Smaller migration with monoblock versus modular tibial component in uncemented TKA. OE Journal. 2017;5(15):5. Available from: https://myorthoevidence.com/AceReport/Show/

نسخ الاقتباس
يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ميزة العضو المميز

للوصول إلى هذه الميزة، يجب عليك تسجيل الدخول إلى حساب OrthoEvidence المميز.

شارك هذا ACE Report