TRAUMA
Single locked plate vs. dual buttress plating for bicondylar tibial plateau fractures .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2025;13(3):40 Knee. 2015 Jun;22(3):225-9
Mitwirkende Autoren

Y Yao H Lv J Zan J Zhang N Zhu R Ning J Jing

86 patients with bicondylar tibial plateau fracture with a relatively intact medial tibial condyle were randomized to receive surgical treatment with either a single lateral locking plate (LP) or dual buttress plates (DP). The purpose of this study was to compare clinical and radiographical outcomes between fixation methods over a minimum of 12 months postoperatively. While the incidence of delayed union was significantly lower in the LP group compared to the DP group, no patient experienced non-union. All other clinical, functional and radiographic outcomes were similar between groups, as well as the incidence of infection. Surgical parameters, such as operative time, blood loss, and hospital stay, were better in the LP group compared to the DP group.


Details zur Finanzierung der Veröffentlichung +
Finanzierung:
Not Reported
Conflicts:
None disclosed

Risiko der Voreingenommenheit

6,5/10

Kriterien für die Berichterstattung

18/20

Fragilitäts-Index

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Ja = 1

Ungewiss = 0.5

Nicht relevant = 0

Nein = 0

Die Bewertung der Berichtskriterien bewertet die Transparenz, mit der die Autoren die methodischen und studienspezifischen Merkmale der Studie in der Veröffentlichung angeben. Die Bewertung ist in fünf Kategorien unterteilt, die im Folgenden vorgestellt werden.

3/4

Randomization

3/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

Der Fragilitätsindex ist ein Instrument, das bei der Interpretation signifikanter Ergebnisse hilft und ein Maß für die Stärke eines Ergebnisses liefert. Der Fragilitätsindex gibt die Anzahl der aufeinanderfolgenden Ereignisse an, die zu einem dichotomen Ergebnis hinzugefügt werden müssen, damit das Ergebnis nicht mehr signifikant ist. Eine kleine Zahl steht für ein schwächeres Ergebnis und eine große Zahl für ein stärkeres Ergebnis.

Warum wurde diese Studie jetzt benötigt?

Bicondylar tibial plateau fractures continue to present a challenge to orthopedic surgeons due to their complexity, often as a result of a motor vehicle accident. Plate fixation is often used in the management of such injuries. Dual buttress plate fixation has been cited as advantageous with respect to fixation stability, but concerns with this method include soft-tissue healing and periosteal blood supply. This has led to interest in the use of a single locking plate for fracture fixation, though there are concerns with reduction quality and stability with this fixation method, particularly in cases with severe comminution or unstable medial condyle. It is suggested in cases of a relatively intact medial condyle without comminution, single locking plate fixation may offer a viable alternative. This study sought to compare the efficacy of the described fixation techniques within these specific injuries.

Was war die wichtigste Forschungsfrage?

What is the efficacy of a single lateral locking plate compared to dual buttress plate fixation in the management of bicondylar tibial plateau fractures with a relatively intact medial condyle, as assessed up to 12 months postoperatively?

Merkmale der Studie +
Population:
86 patients with a bicondylar tibial plateau fracture (OTA type C) with a relatively intact medial tibial condyle, and undergoing surgical fixation. Fractures did not involve comminution or a coronal fracture line. Open fractures were included, although Gustilo type III open fracture were excluded. Prior to surgery, transcalcaneal traction was used for 7-14 after admission. Postoperative care and rehabilitation was standardized across groups (85 completed follow up).
Intervention:
Locking-Plate (LP) Group: Participants underwent fixation with a single lateral locking plate (n=42; 41 completed follow up; M=26/F=15; mean age=43.2 +/- 8.9)
Comparison:
Dual-Plate (DP) Group: Participants underwent fixation via dual T- or L-shaped buttress plates (n=44; 44 completed follow up; M=28/F=16; mean age=45.5 +/- 7.2)
Outcomes:
Outcomes of concern included the Hospital for Special Surgery Knee Scoring System (HSS) score, knee range of motion (ROM), degree of joint depression, coronal and frontal angulation, malreduction (intra-articular step off of >/= 2 mm), malalignment (tibial plateau angle [TPA] of 90 degrees and greater or 80 degrees and less or a tibial plateau posterior slope angle [PSA] 15 degrees and greater or less than equal to 5 degrees), loss of alignment (a change of 5 or more degrees in alignment as compared with immediate postoperative radiographs), loss of reduction (an increase of 2mm of articular depression), and rates of delayed union (failure to heal between 16 weeks and 9 months postoperatively) and non-union (no union after 6 months).
Methods:
RCT: Multi-centered
Time:
The mean follow up period was 22 months (range=12-36 months).
Was waren die wichtigsten Ergebnisse?
  • The LP group demonstrated significantly shorter operative time (120 +/- 25min vs. 150 +/- 20min; p<0.05), lower blood loss (300 +/- 28mL vs. 420 +/- 35mL; p>0.05), and shorter length of hospital stay (12.7 +/- 4.3 days vs. 18.6 +/- 2.7 days; p<0.05) compared to the DP group. The amount of time form admission to surgery did not significantly differ between groups (9.6 +/- 3.2 days vs. 10.6 +/- 3.5 days).
  • There were no cases of nonunion observed in either group. The rate of delayed union was significantly lower in the LP group, as compared to the DP group (LP: 0/41; DP: 7/44; p=0.023).
  • There was no significant difference in mean time to union between the LP and DP group (13.2 +/- 2.0 days vs. 16.5 +/- 2.1 days).
  • Rate of loss of alignment was 1/41 in the LP group and 0/44 in the DP group. Rate of loss of reduction was 1/41 in the LP group and 2/44 in the DP group.
  • Two patients in the DP group developed superficial infection. No patient in either group developed deep infection.
  • At 12 months, the LP and DP groups demonstrated similar HSS score (81.3 +/- 8.6 vs. 79.6 +/- 7.6) and knee range of motion (120.8 +/- 11.6deg vs. 115. 8 +/- 15.9deg).
Was sollte ich mir besonders merken?

In the fixation of bicondylar tibial plateau fractures with an intact medial condyle, a single locking plate was associated with significantly shorter operative time, lower blood loss, and shorter length of hospital stay when compared to dual buttress plate fixation. Comparable results between groups were observed for clinical, functional, and radiographical outcomes and complications when assessed over a minimum of 12 months postoperatively, with the exception of incidence of delayed union, which was significantly lower following single locking plating fixation.

Wie wird sich dies auf die Behandlung meiner Patienten auswirken?

The results of this study suggest that in the particular case of bicondylar tibial plateau fractures with an intact medial condyle, a single locking plate may offer similar results to dual buttress plate fixation, while possibly being advantageous with respect to operating time and hospital stay. Further studies with larger sample sizes are required to verify the current results.

HAFTUNGSAUSSCHLUSS

Der Inhalt dieser Seite dient nur zu Informationszwecken und ist nicht als Ersatz für professionelle medizinische Beratung, Diagnose oder Behandlung gedacht. Wenn Sie eine medizinische Behandlung benötigen, wenden Sie sich immer an Ihren Arzt oder suchen Sie die nächstgelegene Notaufnahme auf. Die Meinungen, Überzeugungen und Standpunkte, die von den Personen auf dieser Seite geäußert werden, spiegeln nicht die Meinungen, Überzeugungen und Standpunkte von OrthoEvidence wider.

0 von 4 monatliche KOSTENLOSE Artikel freigeschaltet
Sie haben Ihr Limit von 4 kostenlosen Artikeln in diesem Monat erreicht

Zugang zu OrthoEvidence für nur $1,99 pro Woche.

Bleiben Sie auf dem Laufenden mit den neuesten Beweisen. Jederzeit kündbar.
  • Kritische Beurteilungen der neuesten, hochwirksamen randomisierten kontrollierten Studien und systematischen Übersichten in der Orthopädie
  • Zugang zu OrthoEvidence-Podcast-Inhalten, einschließlich Kooperationen mit dem Journal of Bone and Joint Surgery, Interviews mit international anerkannten Chirurgen und Diskussionsrunden zu orthopädischen Neuigkeiten und Themen
  • Abonnement von The Pulse, einem zweimal wöchentlich erscheinenden evidenzbasierten Newsletter, der Ihnen helfen soll, bessere klinische Entscheidungen zu treffen
Upgrade
Willkommen zurück!
Passwort vergessen?
Starten Sie Ihre KOSTENLOSE Testversion noch heute!

Ihr Konto ist verbunden mit
und umfasst den kostenlosen Zugang zu OrthoEvidence


ODER
Passwort vergessen?

ODER
Bitte überprüfen Sie Ihre E-Mail

Wenn ein Konto mit der angegebenen E-Mail-Adresse existiert, wird Ihnen eine E-Mail zum Zurücksetzen des Passworts zugesandt. Wenn Sie keine E-Mail sehen, überprüfen Sie bitte Ihren Spam- oder Junk-Ordner.

Für weitere Hilfe, kontaktieren Sie unser Support-Team.

Bitte melden Sie sich an, um diese Funktion zu aktivieren

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem aktiven OrthoEvidence-Konto angemeldet sein. Bitte melden Sie sich an oder erstellen Sie ein KOSTENLOSES Testkonto.

Übersetzen ACE Report

OrthoEvidence nutzt einen externen Übersetzungsdienst, um Inhalte in mehreren Sprachen zugänglich zu machen. Bitte beachten Sie, dass trotz aller Bemühungen um Genauigkeit die Übersetzungen nicht immer perfekt sind.

Wie man dies zitiert ACE Report

OrthoEvidence. Single locked plate vs. dual buttress plating for bicondylar tibial plateau fractures. OE Journal. 2025;13(3):40. Available from: https://myorthoevidence.com/AceReport/Show/