Trabecular metal tibial monoblock stable at 5 years despite high initial migration .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(9):16 Acta Orthop. 2012 Feb;83(1):36-40. doi: 10.3109/17453674.2011.645196. Epub 2011 Dec 29
المؤلفون المساهمون

DA Wilson G Richardson AW Hennigar MJ Dunbar

This study was conducted to examine the 5-year radiostereometric (RSA) results of the trabecular metal (TM) tibial monoblock component, based on a previous study with a follow-up time of 2 years. 70 patients with osteoarthritis were randomized and received either the trabecular metal tibial implant or the cemented component. Results indicated that stability was observed in the trabecular metal tibial implant up to 5 years despite high levels of initial migration observed in the previous study.


تفاصيل تمويل المنشور +
التمويل:
Industry funded
الراعي:
Zimmer Inc. and Dalhousie Medical Research Foundation
Conflicts:
None disclosed

مخاطر التحيز

6/10

معايير الإبلاغ

11/20

مؤشر الهشاشة

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

نعم = 1

غير مؤكد = 0.5

غير ذي صلة = 0

لا = 0

يقيّم تقييم معايير الإبلاغ الشفافية التي يبلغ بها المؤلفون عن الخصائص المنهجية والتجريبية للتجربة في المنشور. ينقسم التقييم إلى خمس فئات معروضة أدناه.

2/4

Randomization

2/4

Outcome Measurements

1/4

Inclusion / Exclusion

2/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

مؤشر الهشاشة هو أداة تساعد في تفسير النتائج المهمة، وتوفر مقياسًا لقوة النتيجة. ويمثل مؤشر الهشاشة عدد الأحداث المتتالية التي يجب إضافتها إلى نتيجة ثنائية التفرع لجعل النتيجة غير مهمة. يمثل الرقم الصغير نتيجة أضعف ويمثل الرقم الكبير نتيجة أقوى.

لماذا كانت هناك حاجة لهذه الدراسة الآن؟

The potential for improved longevity from the use of uncemented implants have been explored due to recent improvement in biomaterials. In a previous paper by the same authors, the 2-year implant migration results of the trabecular metal tibial monoblock component were presented. However, a longer follow-up was necessary to determine whether the early stability of these implants was sustained. Thus, this study presented the 5-year longitudinal radiostereometric (RSA) results from the original cohort of patients randomized to receive either the uncemented Nexgen LPS TM monoblock tibial component or the cemented NexGen Option Stemmed tibial component.

ما هو سؤال البحث الرئيسي؟

Did the trabecular metal tibial implant achieve solid fixation (despite high levels of initial migration) in comparison to the cemented component, assessed at 5 years?

خصائص الدراسة +
Population:
70 patients with severe osteoarthritis (n = 45 at follow-up).
Intervention:
Trabecular metal group: Patients received Nexgen LPS monoblock trabecular metal tibial component (TM) (Mean age: 60) (n = 37; n = 27 at follow-up).
Comparison:
Cemented group: Patients received cemented NexGen Option Stemmed tibial component (Mean age: 61) (n = 33; n = 18 at follow-up).
Outcomes:
The radiostereometric analysis (RSA) was performed through the use of commercial software. The maximum total point motion (MTPM) was calculated through the use of fictive markers in order to standardize the calculations in cases where the prosthesis bead placement was not uniform for all patients. Knee implant was characterized as either “stable” (<0.2 mm maximum total point motion between 1 and 2 years’ follow-up) or as being “at risk” or early aseptic loosening (>0.2 mm maximum total point motion between 1 and 2 years’ follow-up). The Western Ontario and McMaster University Osteoarthritis Index (WOMAC) score was also recorded.
Methods:
RCT
Time:
5 years (assessed at 6 months, 1 year, 2 years, and 5 years).
ما هي النتائج المهمة؟
  • No differences were observed in the WOMAC scores between the groups at any follow-up point (P > 0.006).
  • In the cemented group, the proportion of “at risk” components at 5 years was 2 of 18 (0.11, 95% CI: 0.03-0.33) and for the trabecular metal group it was 0 of 27 (95% CI: 0.0-0.13) (P = 0.2).
  • There was no difference in maximum total point motion at the 5-year follow-up between both groups (P = 0.9); compared to the cemented group, the trabecular metal group had more subsidence (P = 0.001).
  • 9 subjects in the trabecular metal group displayed very high migration in the first 6 months postoperatively (> 1.0 mm) at the 2-year follow-up; at 5 years, stability was still seen in all of these implants with an average change in maximum total point motion of 0.10 mm over the 3 years between follow-ups.
ما الذي يجب أن أتذكره أكثر؟

In the previous 2-year report by the authors, uncertainty was expressed concerning the long-term stability of the trabecular metal tibial implant because of the high initial migration seen in some cases. This study revealed that stability was observed in the trabecular metal tibial implant up to 5 years despite high levels of initial migration.

كيف سيؤثر ذلك على رعاية مرضاي؟

The trabecular metal tibial implant appears to achieve solid fixation even though there were high levels of initial migration. However, continued implant surveillance data is required to evaluate the long-term stability of this implant for patients with osteoarthritis.

تنويه

هذا المحتوى الموجود في هذه الصفحة هو لأغراض إعلامية فقط وليس الغرض منه أن يكون بديلاً عن المشورة الطبية المتخصصة أو التشخيص أو العلاج. إذا كنت بحاجة إلى علاج طبي، اطلب دائمًا مشورة طبيبك أو اذهب إلى أقرب قسم طوارئ إليك. الآراء والمعتقدات ووجهات النظر التي يعبر عنها الأفراد في المحتوى الموجود في هذه الصفحة لا تعكس آراء ومعتقدات ووجهات نظر أورثوإيفيدنس.

0 من 4 مقالات مجانية شهرية غير مقفلة
لقد وصلت إلى الحد الأقصى لمشاهدة 4 من 4 مقالات مجانية هذا الشهر

ادخل إلى OrthoEvidence مقابل 1.99 دولارًا أمريكيًا في الأسبوع.

ابق على اتصال بأحدث الأدلة. قم بالإلغاء في أي وقت.
  • تقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في مجال جراحة العظام
  • الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، والمقابلات مع الجراحين المعترف بهم دولياً، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
  • الاشتراك في نشرة The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك على اتخاذ قرارات سريرية أفضل
Upgrade
أهلاً بعودتك!
هل نسيت كلمة المرور؟
ابدأ تجربتك المجانية اليوم!

سيكون حسابك تابعًا لـ
ويتضمن وصولًا مجانيًا إلى OrthoEvidence


أو
هل نسيت كلمة المرور؟

أو
يرجى التحقق من بريدك الإلكتروني

في حالة وجود حساب بعنوان البريد الإلكتروني المقدم، سيتم إرسال بريد إلكتروني لإعادة تعيين كلمة المرور إليك. إذا كنت لا ترى بريدًا إلكترونيًا، يرجى التحقق من مجلد الرسائل غير المرغوب فيها أو البريد غير المرغوب فيه.

لمزيد من المساعدة اتصل بفريق الدعم لدينا.

يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ترجمة تقرير ACE

تستخدم OrthoEvidence خدمة ترجمة من طرف ثالث لإتاحة المحتوى بلغات متعددة. يُرجى ملاحظة أنه على الرغم من بذل كل جهد ممكن لضمان الدقة، إلا أن الترجمات قد لا تكون دائمًا مثالية.

كيفية الاستشهاد بهذا ACE Report

OrthoEvidence. Trabecular metal tibial monoblock stable at 5 years despite high initial migration. OE Journal. 2013;1(9):16. Available from: https://myorthoevidence.com/AceReport/Show/trabecular-metal-tibial-monoblock-stable-at-5-years-despite-high-initial-migration

نسخ الاقتباس
يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ميزة العضو المميز

للوصول إلى هذه الميزة، يجب عليك تسجيل الدخول إلى حساب OrthoEvidence المميز.

شارك هذا ACE Report