Tibia Fractures: Compartment pressure monitoring does not predict compartment syndrome .
This report has been verified
by one or more authors of the
original publication.
Continuous Compartment Pressure Monitoring for Tibia Fractures: Does It Influence Outcome?
J Trauma. 2006 Jun;60(6):1330-5; discussion 1335200 patients, with acute extra-articular tibia fractures (174 available for follow-up with 177 fractures) were included in a study comparing continuous compartment pressure monitoring to clinical observation for effectiveness in detecting the occurrence of compartment syndrome. Patients were randomized to receive compartment pressure monitoring or usual care (nonmonitoring). After 6 months or at fracture union, there was no significant difference between the two groups for complication rates. No correlation was found between high compartment pressure and development of compartment syndrome.
Vollständigen ACE-Bericht freischalten
Sie haben Zugang zu 4 weiteren KOSTENLOSEN Artikeln in diesem Monat.
Klicken Sie unten, um diese ACE Reports freizuschalten und anzusehen
Jetzt freischalten
Kritische Beurteilungen der neuesten, hochwirksamen randomisierten kontrollierten Studien und systematischen Übersichten in der Orthopädie
Zugang zu OrthoEvidence-Podcast-Inhalten, einschließlich Kooperationen mit dem Journal of Bone and Joint Surgery, Interviews mit international anerkannten Chirurgen und Diskussionsrunden zu orthopädischen Neuigkeiten und Themen
Abonnement von The Pulse, einem zweimal wöchentlich erscheinenden evidenzbasierten Newsletter, der Ihnen helfen soll, bessere klinische Entscheidungen zu treffen
Exklusiver Zugang zu Originalartikeln, einschließlich eigener systematischer Übersichten, sowie zu Artikeln über Methoden der Gesundheitsforschung und aktuelle orthopädische Themen