ARTHROPLASTY
Highly Porous Tantalum Acetabular Components Without Ancillary Screws Are Non-inferior at 7 Years When Compared With Titanium Components With Ancillary Screw Fixation: A Randomized Controlled Trial.
OrthoEvidence Journal (OE Journal) - ACE Report
OE Journal. 2025;13(15):1 Arthroplast Today . 2025 May 17:33:101709.研究概要
Sixty-six patients with primary or secondary osteoarthritis undergoing total hip arthroplasty were randomized intraoperatively to receive either a cementless press-fit solid-backed tantalum acetabular component without ancillary screw fixation (n=33) or a cementless press-fit titanium fiber-metal acetabular component with one ancillary screw (n=33). The primary outcome was proximal acetabular component migration measured by radiostereometric analysis (RSA). Secondary outcomes included migration across other axes, rotation, and Harris Hip Scores. Migration was assessed at baseline (4–6 days), 6 weeks, 3 months, 1, 2, 3, 5, and 7 years. Overall, the results of the study revealed that the mean proximal migration of tantalum components was non-inferior to that of titanium components at both 5 and 7 years. These findings suggest that tantalum acetabular components without ancillary screws offer comparable mid-term stability to titanium components with screws in primary THA.
ACEレポートのロックを解除
4今月はさらに多くの無料記事にアクセスできます。
以下をクリックしてロックを解除し、このACE Reportsをご覧ください。
今すぐロック解除
整形外科における最新のインパクトのあるランダム化比較試験とシステマティックレビューの批判的評価
Journal of Bone and Joint Surgeryとのコラボレーション、国際的に著名な外科医とのインタビュー、整形外科のニュースやトピックに関する座談会など、OrthoEvidenceポッドキャストコンテンツへのアクセス。
週2回発行されるエビデンスに基づくニュースレター、The Pulseの購読。
システマティック・レビュー、健康研究法、整形外科のホットな話題に関する記事など、オリジナル・コンテンツの独占配信
または、今すぐアップグレードして、$1.99/週からすべてのOrthoEvidenceコンテンツにアクセスしてください。
すでにアカウントをお持ちですか? ログイン
パートナー協会に所属していますか?
こちらをクリックすると、協会の会員特典として無料でアクセスできます!