ARTHROPLASTY
Similar long-term clinical and radiological outcomes with mobile- or fixed-bearings in TKA .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2014;2(6):6 J Arthroplasty. 2013 Dec;28(10):1712-6. doi: 10.1016/j.arth.2013.01.003. Epub 2013 Mar 23.
Mitwirkende Autoren

AK Aggarwal A Agrawal

56 patients undergoing unilateral total knee arthroplasty (TKA) were randomized to compare the clinical and radiological outcomes, as well as the safety, of two types of bearing systems. Patients underwent TKA using either a mobile- or fixed-bearing system (Scorpio + Single Axis and Duracon systems, respectively). Results at a final follow-up of 4-6.5 years indicated that most of the clinical outcomes were similar when TKA was performed using either a mobile- or fixed-bearing system, with the exception of range of motion, which favoured the mobile-bearing group. Radiological outcomes, patient satisfaction and the incidence of complications were also statistically similar between groups. Furthermore, the survival rate was 100% using both techniques.


Details zur Finanzierung der Veröffentlichung +
Finanzierung:
Non-funded
Conflicts:
None disclosed

Risiko der Voreingenommenheit

7,5/10

Kriterien für die Berichterstattung

17/20

Fragilitäts-Index

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Ja = 1

Ungewiss = 0.5

Nicht relevant = 0

Nein = 0

Die Bewertung der Berichtskriterien bewertet die Transparenz, mit der die Autoren die methodischen und studienspezifischen Merkmale der Studie in der Veröffentlichung angeben. Die Bewertung ist in fünf Kategorien unterteilt, die im Folgenden vorgestellt werden.

2/4

Randomization

3/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

Der Fragilitätsindex ist ein Instrument, das bei der Interpretation signifikanter Ergebnisse hilft und ein Maß für die Stärke eines Ergebnisses liefert. Der Fragilitätsindex gibt die Anzahl der aufeinanderfolgenden Ereignisse an, die zu einem dichotomen Ergebnis hinzugefügt werden müssen, damit das Ergebnis nicht mehr signifikant ist. Eine kleine Zahl steht für ein schwächeres Ergebnis und eine große Zahl für ein stärkeres Ergebnis.

Warum wurde diese Studie jetzt benötigt?

Total knee arthroplasty (TKA) procedures have traditionally used prostheses comprised of fixed bearings. With the hopes of improving knee kinematics post-surgery, researchers have proposed the use of mobile bearings as an alternative in these procedures. Many studies comparing this relationship (i.e. mobile vs. fixed bearings) have found no significant differences in the clinical and radiological outcomes following TKA. Furthermore, there are no follow-up studies comparing the Scorpio + Single Axis system for mobile-bearing knee prostheses to the Duracon system for fixed-bearing knee prostheses (both Stryker Howmedica Osteonics, Allendale, New Jersey). This study compared mid-term clinical and radiological results obtained using the Duracon versus the Scorpio + Single Axis system.

Was war die wichtigste Forschungsfrage?

Does a mobile-bearing system (Scorpio + Single Axis system) yield better clinical and radiological outcomes, when compared to a fixed-bearing system (Duracon system), in patients undergoing total knee arthroplasty, at a 4- to 6.5-year follow-up?

Merkmale der Studie +
Population:
56 patients undergoing unilateral total knee arthroplasty. Components were cemented in all procedures.
Intervention:
Mobile-bearing (MB) group: Patients in this group (n=29) underwent cemented total knee arthroplasty (TKA) using a mobile-bearing system (Scorpio + Single Axis system (Stryker Howmedica Osteonics, Allendale, New Jersey)). The femoral component used in this system has a single anteroposterior (AP) radius and single axis of knee flexion in the epicondylar axis. The axis of flexion was placed more posteriorly in hopes of increasing the efficiency of the quadriceps. The tibial component had a symmetrical base plate, and was fabricated such that it required minimal bone removal. This mobile-bearing system allowed for unlimited internal and external rotation; however AP translation was not possible. (Mean age: 60.0 +/- 7.1 years; 24 females; 5 males).
Comparison:
Fixed-bearing (FB) group: Patients in this group (n=27) underwent cemented total knee arthroplasty (TKA) using a fixed-bearing system (Duracon system (Stryker Howmedica Osteonics, Allendale, New Jersey)). The femoral component used in this system is characterized by a traditional round-on-flat conformation. The tibial insert used in this group was fixed to the base plate with a snap-fit mechanism. (Mean age: 54.6 +/- 7.9 years; 23 females; 4 males).
Outcomes:
Outcomes assessed included Oxford Knee Scores (OKS), Knee Society Scores (KSS) (with Knee Society Knee Scores (KSKS) and Knee Society Functional Scores (KSFS) as subsets), radiological outcomes (alignment of the knee and positions of the femoral and tibial components), patient satisfaction, and the incidence of complications.
Methods:
RCT; Double-blinded (patients & assessors); Single-Center
Time:
Follow-up assessments took place at 3, 6, and 12 months postoperatively. A final follow up also took place at a mean of 67.3 and 66.4 months in the mobile- and fixed-bearing groups, respectively.
Was waren die wichtigsten Ergebnisse?
  • At final follow-up, there were no significant between-group differences in OKS scores (MB group: 16.6 +/- 1.0 points; FB group: 17.9 +/- 1.4 points; p=0.312) or pain scores (MB group: 44.1 +/- 3.4 points; FB group: 46.4 +/- 3.3 points; p=0.296).
  • KSS scores were also statistically similar in the mobile-bearing (173.9 +/- 10.5 points) and fixed-bearing (161.2 +/- 8.7 points) groups at final follow-up (p=0.059). Similar results were observed for the KSFS (p=0.060) and KSKS (p=0.365) subsets of the KSS assessment tool.
  • Range of motion (ROM) at final follow-up was 125.3 and 110.4 degrees in the mobile- and fixed-bearing group, respectively. This was a statistically significant difference (p=0.016).
  • In the mobile-bearing group, 72% of patients could sit cross legged, 48% could sit on the floor, and 17% could squat, while in the fixed-bearing group, these percentages were 19%, 7% and 0%, respectively.
  • All radiological outcomes (knee alignment, position of the femoral and tibial components in the sagittal and coronal planes, and the shift in joint line) were similar between groups (p>0.05). There were no radiolucent lines seen in any knee throughout the study.
  • All patients who received TKA with the fixed-bearing system were satisfied with the procedure, whereas 2 patients in the mobile-bearing group reported dissatisfaction with the procedure (stating it was due to their inability to squat). The difference in patient satisfaction was not significant (p=0.14).
  • 3 patients in the mobile-bearing group and 4 patients in the fixed-bearing group reported anterior knee pain when rising from a chair or climbing stairs (p=0.49). In addition, 5 patients in the mobile-bearing group and 0 patients in the fixed-bearing group reported an asymptomatic clicking sensation in the knees.
  • No complications were reported in either group. Furthermore, the Kaplan-Meier survival rate was 100% in both groups at final follow-up.
Was sollte ich mir besonders merken?

Most of the clinical outcomes were similar at final follow-up when total knee arthroplasty (TKA) was performed using either a mobile- or fixed-bearing system, with the exception of range of motion, which was greater in the mobile-bearing group. Radiological outcomes, patient satisfaction and the incidence of complications were also statistically similar between groups. Furthermore, survivorship at a follow-up between 4 and 6.5 years was 100% using both techniques.

Wie wird sich dies auf die Behandlung meiner Patienten auswirken?

Although the use of a mobile-bearing system in total knee arthroplasty (TKA) provides some clinical benefits over a fixed-bearing system, most clinical outcomes are comparable between the two. The use of mobile- and fixed-bearing systems also yields similar safety and radiological outcomes. Additional long-term studies are needed, however, to compare these two systems in terms of polyethylene wear and periprosthetic osteolysis.

HAFTUNGSAUSSCHLUSS

Der Inhalt dieser Seite dient nur zu Informationszwecken und ist nicht als Ersatz für professionelle medizinische Beratung, Diagnose oder Behandlung gedacht. Wenn Sie eine medizinische Behandlung benötigen, wenden Sie sich immer an Ihren Arzt oder suchen Sie die nächstgelegene Notaufnahme auf. Die Meinungen, Überzeugungen und Standpunkte, die von den Personen auf dieser Seite geäußert werden, spiegeln nicht die Meinungen, Überzeugungen und Standpunkte von OrthoEvidence wider.

0 von 4 monatliche KOSTENLOSE Artikel freigeschaltet
Sie haben Ihr Limit von 4 kostenlosen Artikeln in diesem Monat erreicht

Zugang zu OrthoEvidence für nur $1,99 pro Woche.

Bleiben Sie auf dem Laufenden mit den neuesten Beweisen. Jederzeit kündbar.
  • Kritische Beurteilungen der neuesten, hochwirksamen randomisierten kontrollierten Studien und systematischen Übersichten in der Orthopädie
  • Zugang zu OrthoEvidence-Podcast-Inhalten, einschließlich Kooperationen mit dem Journal of Bone and Joint Surgery, Interviews mit international anerkannten Chirurgen und Diskussionsrunden zu orthopädischen Neuigkeiten und Themen
  • Abonnement von The Pulse, einem zweimal wöchentlich erscheinenden evidenzbasierten Newsletter, der Ihnen helfen soll, bessere klinische Entscheidungen zu treffen
Upgrade
Willkommen zurück!
Passwort vergessen?
Starten Sie Ihre KOSTENLOSE Testversion noch heute!

Ihr Konto ist verbunden mit
und umfasst den kostenlosen Zugang zu OrthoEvidence


ODER
Passwort vergessen?

ODER
Bitte überprüfen Sie Ihre E-Mail

Wenn ein Konto mit der angegebenen E-Mail-Adresse existiert, wird Ihnen eine E-Mail zum Zurücksetzen des Passworts zugesandt. Wenn Sie keine E-Mail sehen, überprüfen Sie bitte Ihren Spam- oder Junk-Ordner.

Für weitere Hilfe, kontaktieren Sie unser Support-Team.

Bitte melden Sie sich an, um diese Funktion zu aktivieren

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem aktiven OrthoEvidence-Konto angemeldet sein. Bitte melden Sie sich an oder erstellen Sie ein KOSTENLOSES Testkonto.

Übersetzen ACE Report

OrthoEvidence nutzt einen externen Übersetzungsdienst, um Inhalte in mehreren Sprachen zugänglich zu machen. Bitte beachten Sie, dass trotz aller Bemühungen um Genauigkeit die Übersetzungen nicht immer perfekt sind.

Wie man dies zitiert ACE Report

OrthoEvidence. Similar long-term clinical and radiological outcomes with mobile- or fixed-bearings in TKA. OE Journal. 2014;2(6):6. Available from: https://myorthoevidence.com/AceReport/Show/similar-long-term-clinical-and-radiological-outcomes-with-mobile-or-fixed-bearings-in-tka

Zitat kopieren
Bitte melden Sie sich an, um diese Funktion zu aktivieren

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem aktiven OrthoEvidence-Konto angemeldet sein. Bitte melden Sie sich an oder erstellen Sie ein KOSTENLOSES Testkonto.

Premium-Mitglied-Funktion

Um auf diese Funktion zugreifen zu können, müssen Sie bei einem Premium-Konto von OrthoEvidence angemeldet sein.

Teilen Sie dies ACE Report