Similar 5-year clinical outcomes between patient specific and conventional instrumentation in TKA .
No difference in mid-term survival and clinical outcome between patient-specific and conventional instrumented total knee arthroplasty: a randomized controlled trial
Knee Surg Sports Traumatol Arthrosc. 2019 May;27(5):1463-1468.180 patients with knee osteoarthritis and scheduled for a primary unilateral total knee arthroplasty (TKA) were randomized to receive implant alignment with either with patient specific instrumentation (PSI) or conventional instrumentation (CI). Outcomes of interest included revision rate, the Knee Society Score (KSS), Oxford Knee Score (OKS), Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index, pain on a Visual Analog Scale (VAS), the Euro-QoL-5D (EQ-5D) and EQ-5D on a VAS. In this follow up study, follow up was performed at 5 years. Results revealed no significant differences between the PSI and CI groups in KSS, OKS, WOMAC score, VAS pain, EQ-5D or EQ-5D VAS at 5 years. Revision surgery was reported in one case in the PSI group and three cases in the CI group.
افتح تقرير ACE الكامل
لديك إمكانية الوصول إلى المزيد من المقالات المجانية هذا الشهر، انقر أدناه لفتح هذا ACE Reports
افتح الآنتقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في جراحة العظام
الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، ومقابلات مع جراحين معترف بهم دوليًا، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
الاشتراك في النشرة الإخبارية The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك في اتخاذ قرارات سريرية أفضل
إمكانية الوصول الحصري إلى مقالات المحتوى الأصلي، بما في ذلك المراجعات المنهجية الداخلية، ومقالات عن طرق البحث الصحي وموضوعات جراحة العظام الساخنة