Revision TKA with tantalum metaphyseal cones does not result in greater bone density .
Bone mineral density changes of the proximal tibia after revision total knee arthroplasty. A randomised study with the use of porous tantalum metaphyseal cones
Int Orthop. 2012 Sep;36(9):1857-63. Epub 2012 Jun 2640 patients with bone loss to the proximal tibia were randomized to receive conventional revision total knee arthroplasty (rTKA) or rTKA with the “Trabecular Metal Cone” (TM Cone). Although both groups improved significantly in function scores after 24 months, no significant difference was found between them. The two groups also did not differ significantly in their changes in bone mineral density at 12 and 24 months. This study indicates that there was a similar bone remodelling pattern seen between the two procedures.