Potential functional benefit of the olecranon memory connector following fracture .
OrthoEvidence Journal (OE Journal) - ACE Report
OE Journal. 2013;1(11):218 Int Orthop. 2013 Jun;37(6):1099-105. doi: 10.1007/s00264-013-1878-5. Epub 2013 Apr 1840 patients who suffered olecranon fractures were randomized to be treated with either the nickel-titanium olecranon memory connector (OMC) or by locking plate fixation. The purpose was to determine the efficacy of the OMC for functional recovery. After an average of 3.2 years of follow-up, functional recovery assessed through the Mayo Elbow Performance score indicated a significantly better outcome with OMC, whereas functional recovery measured using the Disabilities of the Arm, Shoulder and Hand (DASH) suggested no significant difference between groups.
Was the allocation sequence adequately generated?
Was allocation adequately concealed?
Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?
Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?
Blinding Patients: Was knowledge of the allocated interventions adequately prevented?
Was loss to follow-up (missing outcome data) infrequent?
Are reports of the study free of suggestion of selective outcome reporting?
Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?
Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?
Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?
Sim = 1
Incerto = 0,5
Não relevante = 0
Não = 0
A Avaliação dos Critérios de Relato avalia a transparência com que os autores relatam as caraterísticas metodológicas e do ensaio na publicação. A avaliação está dividida em cinco categorias que são apresentadas de seguida.
3/4
Randomization
2/4
Outcome Measurements
4/4
Inclusion / Exclusion
3/4
Therapy Description
3/4
Statistics
Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65
O Índice de Fragilidade é uma ferramenta que auxilia na interpretação de achados significativos, fornecendo uma medida de força para um resultado. O Índice de Fragilidade representa o número de eventos consecutivos que precisam de ser adicionados a um resultado dicotómico para que o resultado deixe de ser significativo. Um número pequeno representa um resultado mais fraco e um número grande representa um resultado mais forte.
Porque é que este estudo era necessário agora?
Olecranon fractures represent a significant number of fractures occurring around the elbow. Internal fixation, tension-band wiring, plate fixation and intramedullary screws/nails have commonly been used to treat such fractures, although entail limitations. A nickel-titanium olecranon memory connector, made up of an intramedullary fixing lock, a base arc and two compression fixing arms, has been developed as a potential alternative treatment. Accordingly, a comparison to standard treatment methods was needed to determine its efficacy.
Qual era a principal questão de investigação?
What was the efficacy of the olecranon memory connector when compared to locking plate fixation for the treatment of olecranon fractures, assessed at an average of 3.2 years follow-up?
- Mean DASH score was 3.3 (+/-4.0) in the OMC group and 4.0 (+/-6.9) in the locking plate group. The difference was not significant (P=0.38).
- Mean MEP score was 86.7 (+/-12.5) in the OMC group and 79.8 (+/-12.3) in the locking plate group. The difference was found to be significant, indicating a superior outcome in the OMC group (P<0.05).
- MEP score for elbow function in the OMC group was excellent in 10 patients (50%), good in 7 (35%), and fair in 3 (15%). For the locking plate group, MEP score was excellent in 5 patients (25%), good in 10 (50%), fair in 4 (20%) and poor in 1 (5%).
- Poor MEP outcome for the locking plate group was due to a postoperative superficial infection. The was the only implant-related complication noted in either group. This also resulted in the patient being dissatisfied with their treatment
- Seventeen patients (85%) of both groups were very satisfied with their treatment. The remaining patients were satisfied with treatment (except for the case described above).
- Groups did not significantly differ with respect to range of motion in flexion, extension, pronation and supination.
De que é que me devo lembrar mais?
Functional recovery was significantly better with the olecranon memory connector when measured by the Mayo Elbow Performance score, but no significance was displayed between treatments for the DASH evaluation. Range of motion was not demonstrated to be significantly different between groups.
Como é que isto afectará o tratamento dos meus doentes?
These results preliminarily outline the possibility of alternative treatment of olecranon fractures with the olecranon memory connector, with a potential benefit in functional recovery. An investigation with a larger number of patients is required to confirm these results.
AVISO LEGAL
O conteúdo desta página destina-se apenas a fins informativos e não pretende substituir o aconselhamento, diagnóstico ou tratamento médico profissional. Se necessitar de tratamento médico, procure sempre o conselho do seu médico ou dirija-se ao serviço de urgência mais próximo. As opiniões, crenças e pontos de vista expressos pelos indivíduos no conteúdo encontrado nesta página não reflectem as opiniões, crenças e pontos de vista da OrthoEvidence.