Posterior-stabilized implants designed for increased flexion improves ROM after TKA .
A Randomized, Prospective Study of Primary Total Knee Components Designed for Increased Flexion
J Arthroplasty. 2007 Apr;22(3):349-52. Epub 2007 Jan 2250 patients undergoing primary total knee arthroplasty (TKA) were randomized to two different knee implants designs to examine postoperative range of motion (ROM). One group had posterior-stabilized (PS) implants designed for increased flexion while the other group had standard PS implants. Results showed that the PS implants designed for increased flexion resulted in better ROM results compared to the standard implant at the 12-month follow-up.
Vollständigen ACE-Bericht freischalten
Sie haben Zugang zu 4 weiteren KOSTENLOSEN Artikeln in diesem Monat.
Klicken Sie unten, um diese ACE Reports freizuschalten und anzusehen
Jetzt freischalten
Kritische Beurteilungen der neuesten, hochwirksamen randomisierten kontrollierten Studien und systematischen Übersichten in der Orthopädie
Zugang zu OrthoEvidence-Podcast-Inhalten, einschließlich Kooperationen mit dem Journal of Bone and Joint Surgery, Interviews mit international anerkannten Chirurgen und Diskussionsrunden zu orthopädischen Neuigkeiten und Themen
Abonnement von The Pulse, einem zweimal wöchentlich erscheinenden evidenzbasierten Newsletter, der Ihnen helfen soll, bessere klinische Entscheidungen zu treffen
Exklusiver Zugang zu Originalartikeln, einschließlich eigener systematischer Übersichten, sowie zu Artikeln über Methoden der Gesundheitsforschung und aktuelle orthopädische Themen