No benefit of angular stable locking for intramedullary nailing of distal tibial fractures .
This report has been verified
by one or more authors of the
original publication.
Evaluation of the effectiveness of the angular stable locking system in patients with distal tibial fractures treated with intramedullary nailing: a multicenter randomized controlled trial
J Bone Joint Surg Am. 2014 Nov 19;96(22):1889-97.142 patients who suffered a distal tibial fracture were randomized to undergo intramedullary nailing locked with an angular stable locking system or conventional locking screws. The intent of this study was to determine which locking method achieved earlier full weight-bearing with minimum pain. Follow-up was performed up to 12 months postoperatively. No clinically important differences were observed for time to full weight-bearing with minimum pain or any secondary outcome.
افتح تقرير ACE الكامل
لديك إمكانية الوصول إلى المزيد من المقالات المجانية هذا الشهر، انقر أدناه لفتح هذا ACE Reports
افتح الآنتقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في جراحة العظام
الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، ومقابلات مع جراحين معترف بهم دوليًا، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
الاشتراك في النشرة الإخبارية The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك في اتخاذ قرارات سريرية أفضل
إمكانية الوصول الحصري إلى مقالات المحتوى الأصلي، بما في ذلك المراجعات المنهجية الداخلية، ومقالات عن طرق البحث الصحي وموضوعات جراحة العظام الساخنة