Mid-term migration of the Triathlon versus Duracon total knee systems .
This report has been verified
by one or more authors of the
original publication.
OrthoEvidence Journal (OE Journal) - ACE Report
OE Journal. 2016;4(20):1 Acta Orthop. 2016 Jun;87(3):262-760 patients with knee osteoarthritis and scheduled for total knee arthroplasty were randomized to receive either a newer-generation Triathlon total knee system, or older-generation Duracon total knee system. The purpose of this study was to compare tibial component stability between groups at short- and mid-term follow-up. Three-dimensional translation and rotation of the component were assessed using radiostereometric analysis. After 5 years, significant difference between groups was only observed in varus-valgus rotation.
Was the allocation sequence adequately generated?
Was allocation adequately concealed?
Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?
Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?
Blinding Patients: Was knowledge of the allocated interventions adequately prevented?
Was loss to follow-up (missing outcome data) infrequent?
Are reports of the study free of suggestion of selective outcome reporting?
Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?
Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?
Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?
Ja = 1
Ungewiss = 0.5
Nicht relevant = 0
Nein = 0
Die Bewertung der Berichtskriterien bewertet die Transparenz, mit der die Autoren die methodischen und studienspezifischen Merkmale der Studie in der Veröffentlichung angeben. Die Bewertung ist in fünf Kategorien unterteilt, die im Folgenden vorgestellt werden.
2/4
Aleatorización
3/4
Medición de resultados
2/4
Inclusión / exclusión
0/4
Descripción de la terapia
4/4
Estadísticas
Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65
Der Fragilitätsindex ist ein Instrument, das bei der Interpretation signifikanter Ergebnisse hilft und ein Maß für die Stärke eines Ergebnisses liefert. Der Fragilitätsindex gibt die Anzahl der aufeinanderfolgenden Ereignisse an, die zu einem dichotomen Ergebnis hinzugefügt werden müssen, damit das Ergebnis nicht mehr signifikant ist. Eine kleine Zahl steht für ein schwächeres Ergebnis und eine große Zahl für ein stärkeres Ergebnis.
Warum wurde diese Studie jetzt benötigt?
The evolution of prostheses for total knee arthroplasty is continuously ongoing. Newer-generation implants are typically released and phased into clinical practice, ultimately replacing routine use of earlier-generation implants over many years. Within this process, careful consideration of long-term outcome of new implants is crucial to ensure patients are not experiencing worse stability and survivorship compared to older implants with proven track records.
Was war die wichtigste Forschungsfrage?
In total knee arthroplasty, was there any significant difference in radiostereometrically-assessed micromotion of the tibial component between the Triathlon and Duracon cemented knee systems over 5-year follow-up?
- No significant differences between the Duracon and Triathlon groups were observed after 5 years in medial-lateral translation (-0.34+/-1.26 vs. -0.33+/-0.46mm; p=1.0), caudal-cranial translation (-0.5+/-0.51 vs. 0.1+/-0.27mm; p=0.2), or posterior-anterior translation (-0.33+/-1.22 vs. 0.18+/-0.59; p=0.1).
- Overall, mean MTPM after 5 years did not significantly differ between the Duracon group (1.10+/-1.21) and the Triathlon group (0.66+/-0.38)
- No significant differences between the Duracon and Triathlon groups were observed after 5 years in anterior-posterior tilt (0.10+/-0.38 vs. -0.9+/-0.31deg; p=0.1) or internal-external rotation (-0.19+/-0.64 vs. -0.09+/-0.31deg; p=0.5). A significant difference was observed between groups in varus-valgus rotation of the component after 5 years, with 0.18deg (+/-0.48) varus rotation in the Duracon group versus 0.09deg (+/-0.28) valgus rotation in the Triathlon group.
- Continuous migration of the tibial component between years 1 and 2 was observed in 7/24 patients of the Duracon group and 5/26 patients of the Triathlon group.
- Continuous migration of the tibial component between years 2 and 5 was observed in 6/21 patients of the Duracon group and 3/21 patients of the Triathlon group (p=0.2).
Was sollte ich mir besonders merken?
In total knee arthroplasty, 5-year maximum total point motion of the tibial component did not significantly differ between patients treated with a Triathlon or Duracon prosthesis. A similar number of patients between groups throughout follow-up demonstrated MTPM values exceeding the thresholds set by the current study as indicative of continuous migration.
Wie wird sich dies auf die Behandlung meiner Patienten auswirken?
The results of this study suggest that the newer-generation Triathlon total knee system has a similar mid-term migration profile to that of the predecessor-generation Duracon total knee system. Continued follow-up is necessary to determine if the migration profiles of these two systems remain similar into the long-term.
HAFTUNGSAUSSCHLUSS
Der Inhalt dieser Seite dient nur zu Informationszwecken und ist nicht als Ersatz für professionelle medizinische Beratung, Diagnose oder Behandlung gedacht. Wenn Sie eine medizinische Behandlung benötigen, wenden Sie sich immer an Ihren Arzt oder suchen Sie die nächstgelegene Notaufnahme auf. Die Meinungen, Überzeugungen und Standpunkte, die von den Personen auf dieser Seite geäußert werden, spiegeln nicht die Meinungen, Überzeugungen und Standpunkte von OrthoEvidence wider.