ACE Report Cover
Low-intensity pulsed ultrasound not cost-effective following IM nailing of fresh tibial fracture
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
言語
Download Download Download
ダウンロード
Cite this Report Cite this Report Cite this Report
引用
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ お気に入り
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
言語
Download Download Download
ダウンロード
Cite this Report Cite this Report Cite this Report
引用
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ お気に入り

TRAUMA

Low-intensity pulsed ultrasound for treatment of tibial fractures: an economic evaluation of the TRUST study

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2018;6(9):19 Bone Joint J. 2017 Nov;99-B(11):1526-1532

501 patients who had undergone intramedullary nail fixation for a fresh tibial fracture were randomized to either active low-intensity pulsed ultrasound (LIPUS) or sham LIPUS. Groups were compared for quality-adjusted life-years, based on the Health Utility Index Mark-3 (HUI-3), costs in 2015 Canadian dollars associated with treatment, and a cost-utility analysis was performed. Active LIPUS demonstrated significantly greater costs compared to the sham group, with no significant difference in QALYs. Incremental cost-effectiveness ratios (ICER) ranged from $146,006/QALY gained to $155,443/QALY gained with the use of LIPUS, and cost-effectiveness acceptability curves (CEAC) estimated 1% likelihood of LIPUS being cost-effective at a willingness-to-pay threshold of $50,000 from a payer perspective.


出版資金提供の詳細 +
資金提供:
Non-Industry funded
スポンサー:
Canadian Institutes of Health Research (CIHR)
コンフリクト:
Other

バイアスのリスク

8/10

報告基準

20/21

脆弱性指数

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

はい = 1

不確実=0.5

無関係 = 0

いいえ = 0

報告基準評価では、著者が出版物内で試験の方法論的特徴や試験特性を報告する際の透明性を評価します。評価は以下の5つのカテゴリーに分類されます。

4/4

Randomization

4/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/5

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

Fragility Indexは、重要な所見の解釈を助けるツールで、結果の強さの尺度を提供します。Fragility Indexは、その所見が有意でなくなるために、二項対立の結果に追加する必要がある連続した事象の数を表します。数値が小さいほど弱い所見を表し、数値が大きいほど強い所見を表します。

なぜ今この研究が必要なのですか?

Low-intensity pulsed ultrasound (LIPUS) is currently used as an intervention to reduce time to fracture healing and decrease the risk of nonunion. However, high-quality evidence in support of these benefits has been inconsistent, and most recent evidence has pointed to similar outcomes with and without LIPUS treatment. A cost-utility analysis, performed alongside a large randomized controlled trial (The Trial to Re-evaluate Ultrasound in the Treatment of Tibial Fractures [TRUST]) was thus needed.

主な研究課題は何ですか?

Is the use of LIPUS following operative management of a fresh tibial fracture cost-effective, as measured by incremental cost-effectiveness ratio and against willingness-to-pay thresholds of either $50,000 and $100,000?

研究の特徴 +
人口:
501 patients with a fresh tibial fracture that was fixed using an intramedullary nail.
介入:
LIPUS group: Following surgery, patients were given a low-intensity pulsed ultrasound device (Exogen 4000+) to be used for 20 minutes daily until radiographic union. Devices were set to deliver a 30mW/cm2 signal. (n=250)
比較:
Placebo group: Following surgery, patients were given a sham Exogen 4000+ device to be used for 20 minutes daily until radiographic union. (n=251)
アウトカム:
Quality-adjusted life years (QALYs) were calculated from results of the Health Utilities Index Mark-3 (HUI-3). Costs related to devices, secondary interventions & associated hardware, use of physical therapy and occupational therapy postoperatively, medications, and wages lost incurred from time off work were estimated from appropriate references and expressed in 2015 Canadian Dollars.
方法:
RCT; Cost-utility analysis
時間:
Not applicable.

重要な知見は?

  • Total cost from a payer perspective (ie. not including wage loss) was significantly higher in the LIPUS group ($5656 [95%CI 5389-5923]) compared to the placebo group ($2009 [95%CI 1680-2338]) (p<0.001). Total cost from a societal perspective was also significantly higher in the LIPUS group ($13901[95%CI 12616-15186]) compared to the placebo group ($10475 [95%CI 9128-11823]) (p<0.001).
  • Total QALYs gained did not significantly differ between the LIPUS group (0.686 [95%CI 0.666-0.705]) and the placebo group (0.662 [95%CI 0.639-0.685]) (p=0.47).
  • From a payer perspective, ICER was $155,443/QALY gained. From a societal perspective, ICER was $146,006/QALY gained.
  • From a payer perspective, CEAC demonstrated a 1% probability of LIPUS being cost-effective at a willingness-to-pay threshold of $50,000 and a 23% chance of being cost-effective at a willingness-to-pay threshold of $100,000.
  • From a societal perspective, CEAC demonstrated a 5% probability of being cost-effective at a willingness-to-pay threshold of $50,000 and a 31% chance of being cost-effective at a willingness-to-pay threshold of $100,000.
最も覚えておくべきことは?

Following intramedullary nailing of a tibial fracture, low-intensity pulsed ultrasound did not appear to be cost-effective when compared to sham LIPUS.

それが私の患者ケアにどのように影響するか?

The results of this study suggest that routinely prescribing LIPUS use following intramedullary nail fixation of a fresh tibial fracture is unlikely to be a cost-effective practice.

免責事項

このページに記載されている内容は、情報提供のみを目的としたものであり、専門的な医療アドバイス、診断、治療の代わりとなるものではありません。治療が必要な場合は、必ず医師の診断を仰ぐか、最寄りの救急外来を受診してください。このページに記載されている内容に関して個人が表明した意見、信念、見解は、OrthoEvidenceの意見、信念、見解を反映するものではありません。

0の4 月間無料記事のロック解除
今月の無料記事閲覧数が4件に達しました。

週1.99ドルからOrthoEvidenceにアクセスできます。

最新のエビデンスにアクセスしてください。いつでもキャンセルできます。
  • 整形外科における最新のインパクトのあるランダム化比較試験とシステマティックレビューの批判的評価
  • Journal of Bone and Joint Surgeryとのコラボレーション、国際的に著名な外科医へのインタビュー、整形外科ニュースやトピックに関する座談会など、OrthoEvidenceポッドキャストコンテンツへのアクセス
  • 週2回発行されるエビデンスに基づくニュースレター、The Pulseの購読。
Upgrade
Close Dialog
おかえりなさい
パスワードをお忘れですか?
今すぐ無料トライアルを開始

あなたのアカウントは
OrthoEvidenceへの無料アクセスが含まれます。


または
パスワードをお忘れですか?

または
Eメールをご確認ください

入力されたメールアドレスにアカウントが存在する場合、パスワードリセットのメールが送信されます。メールが届かない場合は、迷惑メールフォルダをご確認ください。

その他のサポート サポートチームまでご連絡ください。.

この機能を有効にするにはログインしてください

この機能にアクセスするには、有効なOrthoEvidenceアカウントにログインする必要があります。ログインするか、無料トライアルアカウントを作成してください。

ACEレポートを翻訳

OrthoEvidenceは、多言語でコンテンツにアクセスできるようにするため、第三者の翻訳サービスを利用しています。正確性を確保するためにあらゆる努力をしていますが、翻訳が必ずしも完璧ではない可能性があることにご注意ください。

引用方法 ACE Report

OrthoEvidence. Low-intensity pulsed ultrasound not cost-effective following IM nailing of fresh tibial fracture. OE Journal. 2018;6(9):19. Available from: https://myorthoevidence.com/AceReport/Show/low-intensity-pulsed-ultrasound-not-cost-effective-following-im-nailing-of-fresh-tibial-fracture

引用のコピー
この機能を有効にするにはログインしてください

この機能にアクセスするには、有効なOrthoEvidenceアカウントにログインする必要があります。ログインするか、無料トライアルアカウントを作成してください。

プレミアム会員機能

この機能にアクセスするには、OrthoEvidenceのプレミアムアカウントにログインする必要があります。

共有 ACE Report