ACE Report Cover
Low-intensity pulsed ultrasound improves bone healing in delayed unions of the tibia
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
言語
Download Download Download
ダウンロード
Cite this Report Cite this Report Cite this Report
引用
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ お気に入り
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
言語
Download Download Download
ダウンロード
Cite this Report Cite this Report Cite this Report
引用
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ お気に入り

TRAUMA

Improved healing response in delayed unions of the tibia with low-intensity pulsed ultrasound: results of a randomized sham-controlled trial
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2014;2(9):23 BMC Musculoskelet Disord. 2010 Oct 8;11:229. doi: 10.1186/1471-2474-11-229.

101 patients who had suffered a fracture to the tibial shaft, and for whom delayed union was confirmed were randomized to undergo 16 weeks of active low-intensity pulsed ultrasound (LIPUS) or a sham device, to determine whether LIPUS is effective in promoting bone healing in this population. Results indicated that improvements in bone mineral density (BMD) and gap area at the fracture site were significantly higher in patients treated with LIPUS compared to those treated with a sham device, with a medium degree of effectiveness in patients who completed the protocol. Furthermore, regardless of group allocations, patients whose time since fracture was 48 weeks or more experienced significantly poorer radiological outcomes, compared to fractures experienced <48 weeks prior.


出版資金提供の詳細 +
資金提供:
Industry funded
スポンサー:
Smith & Nephew (Memphis, TN)
コンフリクト:
None disclosed

バイアスのリスク

8/10

報告基準

17/20

脆弱性指数

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

はい = 1

不確実=0.5

無関係 = 0

いいえ = 0

報告基準評価では、著者が出版物内で試験の方法論的特徴や試験特性を報告する際の透明性を評価します。評価は以下の5つのカテゴリーに分類されます。

4/4

Randomization

4/4

Outcome Measurements

2/4

Inclusion / Exclusion

4/4

Therapy Description

3/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

Fragility Indexは、重要な所見の解釈を助けるツールで、結果の強さの尺度を提供します。Fragility Indexは、その所見が有意でなくなるために、二項対立の結果に追加する必要がある連続した事象の数を表します。数値が小さいほど弱い所見を表し、数値が大きいほど強い所見を表します。

なぜ今この研究が必要なのですか?

Previous studies have found low-intensity pulsed ultrasound (LIPUS) to be safe and effective in promoting bone healing in numerous long-bone fracture types. This conservative treatment works by promoting osteoblastic activity, leading to subsequent increases in osteoid thickness, mineral apposition rate, as well as bone volume at the edge of new bone formation in these patients. Only a paucity of studies, the majority of which single-arm, have examined its effectiveness in patients with delayed union as opposed to fresh fractures. This study was therefore needed to contribute to the limited body of evidence in this population.

主な研究課題は何ですか?

Is treatment with low-intensity pulsed ultrasound (LIPUS) for 16 weeks effective in promoting bone healing in patients with a delayed union of a tibial shaft fracture, relative to sham treatment?

研究の特徴 +
人口:
101 patients who had suffered a fracture to the tibial shaft, and for whom delayed union was confirmed. Delayed union was defined as a lack of clinical and radiological evidence of union, bone reaction, or bone continuity at least 16 weeks post-injury or post-treatment (n=84 completed study protocol)
介入:
LIPUS device group: Patients (n=51) received low-intensity pulsed ultrasound (LIPUS) using the Exogen 2000/2000+ (Smith & Nephew GmbH, Schenefeld, Germany) device, 20 minutes/day for 16 weeks. The ultrasound device was set at a frequency of 1.5 MHz, a repetition rate of 1 kHz, a pulse duration of 200 us, and a spatial intensity of 30 mW/cm^2. (Mean age: 42.6 +/- 14.6 years; 29% female)
比較:
Sham device group: Patients (n=50) received a sham treatment using an identical device - without emitting acoustic pressure waves - 20 minutes/day for 16 weeks. (Mean age: 45.1 +/- 11.9 years; 18% female)
アウトカム:
The primary outcomes were bone mineral density (BMD) at the fracture site, 2-3 mm proximal and distal to the index site, as well as gap area (assessed by computed tomography [CT]). BMD was measured in Hounsfield units (HUs). Compliance was also measured by the devices.
方法:
RCT; Multi-Centre (6 sites); Double-blinded (patients & assessors)
時間:
Assessments were performed at 1, 2 and 3 months.

重要な知見は?

  • Based on a descriptive 'completers' analysis (n=84), log BMD increased from baseline to 16 weeks by a mean of 0.87 HU (SD 0.67) in the treatment group and 0.57 HU (SD 0.38) in the control group. This between-group difference was statistically significant in favour of the treatment group (effect size 0.53; 95% CI 0.09, 0.97; p=0.014).
  • Also based on a descriptive 'completers' analysis (n=84), from baseline to 16 weeks, mean changes in log gap area were -0.131 mm^2 (SD 0.072) in the treatment group and -0.097 mm^2 (SD 0.070) in the control group; this between-group difference was statistically significant (effect size -0.47; 95% CI -0.91, -0.03; p=0.034).
  • Multiple imputation analysis revealed an adjusted difference between groups in the mean change in BMD of 122.4 HU (p=0.007). Based on log transformed data, the adjusted mean BMD improvement was also found to be significantly greater in the treatment group (p=0.002).
  • Using multiple imputation analysis, LIPUS was found to have a statistically significant positive effect on bone gap area (based on log transformed data) (p=0.014). A similar finding was observed for untransformed data (p=0.03).
  • Following multiple regression analysis (i.e. including pre-treatment BMD [ratio 0.64], time since fracture of <48 weeks [ratio 1.33], and use of intramedullary nail fixation [ratio 1.23]) the relative effectiveness of the treatment remained significant (p=0.004), with minimal change in magnitude.
  • Mean BMD was 1.33 times higher for patients with a time since fracture <48 weeks compared to 48 weeks or more when LIPUS status was controlled for. Despite these independent findings, a time since injury x study group interaction was not statistically significant (p=0.76), revealing that LIPUS had a significant effect on bone growth whether or not time since fracture was <48 weeks or >48 weeks. Mean BMD was 1.23 times higher for those who received intramedullary nail fixation.
  • At 16 weeks, there was a non-significant trend towards more patients in the treatment group considered "healed" (33/51 or 65%) compared to the control group (23/50 or 46%) (p=0.07).
  • No device-related adverse events were reported.
最も覚えておくべきことは?

Improvement in bone mineral density (BMD) and gap area at the fracture site were significantly higher in patients treated with low-intensity pulsed ultrasound (LIPUS) compared to those treated with a sham device, with a medium degree of effectiveness in 'completers'. Furthermore, regardless of group allocations, patients whose time since fracture was 48 weeks or more experienced significantly poorer radiological outcomes compared to patients treated within 48 weeks of fracture.

それが私の患者ケアにどのように影響するか?

Results from this study support the use of low-intensity pulsed ultrasound (LIPUS) in the treatment of delayed unions of tibial fractures. This study also emphasizes the need for early treatment when delayed unions are suspected. Additional studies with longer follow-ups are needed to confirm the longitudinal effect of this treatment approach.

免責事項

このページに記載されている内容は、情報提供のみを目的としたものであり、専門的な医療アドバイス、診断、治療の代わりとなるものではありません。治療が必要な場合は、必ず医師の診断を仰ぐか、最寄りの救急外来を受診してください。このページに記載されている内容に関して個人が表明した意見、信念、見解は、OrthoEvidenceの意見、信念、見解を反映するものではありません。

0の4 月間無料記事のロック解除
今月の無料記事閲覧数が4件に達しました。

週1.99ドルからOrthoEvidenceにアクセスできます。

最新のエビデンスにアクセスしてください。いつでもキャンセルできます。
  • 整形外科における最新のインパクトのあるランダム化比較試験とシステマティックレビューの批判的評価
  • Journal of Bone and Joint Surgeryとのコラボレーション、国際的に著名な外科医へのインタビュー、整形外科ニュースやトピックに関する座談会など、OrthoEvidenceポッドキャストコンテンツへのアクセス
  • 週2回発行されるエビデンスに基づくニュースレター、The Pulseの購読。
Upgrade
Close Dialog
おかえりなさい
パスワードをお忘れですか?
今すぐ無料トライアルを開始

あなたのアカウントは
OrthoEvidenceへの無料アクセスが含まれます。


または
パスワードをお忘れですか?

または
Eメールをご確認ください

入力されたメールアドレスにアカウントが存在する場合、パスワードリセットのメールが送信されます。メールが届かない場合は、迷惑メールフォルダをご確認ください。

その他のサポート サポートチームまでご連絡ください。.

この機能を有効にするにはログインしてください

この機能にアクセスするには、有効なOrthoEvidenceアカウントにログインする必要があります。ログインするか、無料トライアルアカウントを作成してください。

ACEレポートを翻訳

OrthoEvidenceは、多言語でコンテンツにアクセスできるようにするため、第三者の翻訳サービスを利用しています。正確性を確保するためにあらゆる努力をしていますが、翻訳が必ずしも完璧ではない可能性があることにご注意ください。

引用方法 ACE Report

OrthoEvidence. Low-intensity pulsed ultrasound improves bone healing in delayed unions of the tibia. OE Journal. 2014;2(9):23. Available from: https://myorthoevidence.com/AceReport/Show/low-intensity-pulsed-ultrasound-improves-bone-healing-in-delayed-unions-of-the-tibia

引用のコピー
この機能を有効にするにはログインしてください

この機能にアクセスするには、有効なOrthoEvidenceアカウントにログインする必要があります。ログインするか、無料トライアルアカウントを作成してください。

プレミアム会員機能

この機能にアクセスするには、OrthoEvidenceのプレミアムアカウントにログインする必要があります。

共有 ACE Report