Intramedullary nail beneficial vs locking compression plate for humeral shaft fracture .
Management of Humeral Shaft Fractures With Intramedullary Interlocking Nail Versus Locking Compression Plate
Orthopedics. 2015 Sep 1;38(9):e825-960 patients presenting with humeral shaft fractures were randomized to undergo surgical fixation with either an intramedullary interlocking nail or locking compression plate. The purpose of the study was to compare operational and functional outcomes of these fixation methods over 1 year postoperatively. The results showed that intramedullary nail led to significantly shorter operative times, hospital stay, lower intraoperative blood loss, and earlier fracture union. The groups were comparable in terms of functional outcomes and the incidence of non-union.