ACE Report Cover
Intertrochanteric fractures: Similar rate of reoperation using fixed or sliding side plate
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Langue
Download Download Download
Télécharger
Cite this Report Cite this Report Cite this Report
Citer
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Favoris
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Langue
Download Download Download
Télécharger
Cite this Report Cite this Report Cite this Report
Citer
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Favoris
TRAUMA
Intertrochanteric fractures: Similar rate of reoperation using fixed or sliding side plate .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2014;2(7):39 Injury. 2013 Dec;44(12):1904-9. doi: 10.1016/j.injury.2013.06.017. Epub 2013 Jul 20

163 patients with unstable intertrochanteric fractures were randomized to receive surgical treatment using either (1) a sliding hip screw and fixed side plate or (2) a sliding hip screw and a Medoff sliding side plate. The purpose of this study was to compare rates of re-operation and hip function scores following treatment with these two types of hardware. Results after 6 months indicated that the use of a sliding hip screw with a Medoff sliding side plate resulted in a similar re-operation rate, hip function recovery scores, length of hospital stay, haemoglobin drop, number of transfusions, transfusion units, leg-length discrepancy, loss in range of motion, and the incidence of complications. Surgical time was significantly greater in the Medoff sliding side plate group.


Détails du financement de la publication +
Financement:
Not Reported
Conflits:
None disclosed

Risque de partialité

6/10

Critères de déclaration

16/20

Indice de fragilité

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

Oui = 1

Incertain = 0,5

Non pertinent = 0

Non = 0

L'évaluation des critères de rapport permet d'évaluer la transparence avec laquelle les auteurs rapportent les caractéristiques méthodologiques et les caractéristiques de l'essai dans la publication. L'évaluation est divisée en cinq catégories qui sont présentées ci-dessous.

2/4

Randomization

2/4

Outcome Measurements

4/4

Inclusion / Exclusion

4/4

Therapy Description

4/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

L'indice de fragilité est un outil qui aide à l'interprétation des résultats significatifs, en fournissant une mesure de la force d'un résultat. L'indice de fragilité représente le nombre d'événements consécutifs qui doivent être ajoutés à un résultat dichotomique pour que le résultat ne soit plus significatif. Un petit nombre représente un résultat plus faible et un grand nombre un résultat plus fort.

Pourquoi cette étude était-elle nécessaire maintenant ?

Hip screws are used in the treatment of unstable intertrochanteric hip fractures, however the average failure rate for this treatment remains quite high (15%). As to be expected, this high failure rate may lead to a significantly higher number of re-operations, resulting in increased patient morbidity and health care costs. Previously, when sliding hip screws were introduced into practice, failure rates significantly dropped. Based on this reasoning, it has been suggested that the implementation of both sliding hip screws and sliding plates in the treatment of unstable intertrochanteric hip fractures may result in improved re-operation rates and patient function.

Quelle était la principale question de recherche ?

How does the use of a sliding hip screw and a sliding side plate compare to the use of a sliding hip screw and fixed side plate in the treatment of unstable intertrochanteric fractures, with respect to re-operation rate and patient function assessed at 6 months postoperatively?

Caractéristiques de l'étude +
Population:
163 patients (median 83 years old) with unstable intertrochanteric hip fractures (Jensen and Michaelsen Type IV and V fractures; OTA 31-A2 fractures) (124 females; 39 males).
Intervention:
MSP group: Patients in this group (n=77) underwent surgical treatment of their intertrochanteric hip fracture using a sliding hip screw with a Medoff sliding side plate (MSP; Wright Medical Group, Arlington, TN, USA). The sliding Medoff 135-degree side plate (MSP) was placed over the hip screw and fixed with cortical screws. (Mean age: 83.6 years; 18 males, 59 females).
Comparaison:
DHS group: Patients in this group (n=86) underwent surgical treatment of their intertrochanteric hip fracture using a sliding hip screw with a fixed side plate (dynamic hip screw, DHS; Synthes (Canada) Ltd., Mississauga, ON, USA). The fixed Synthes 135-degree plate (four holes) was placed over the hip screw and fixed with cortical screws. (Mean age: 83 years; 21 males, 65 females).
Résultats:
The primary outcome was re-operation rate. Secondary outcomes included patient function (assessed using the Geriatric Hip Fracture Recovery Score (GHFRS)), morbidity, mortality, hospital stay, quality of reduction, and the incidence of non-union/malunion (assessed using radiographic imaging).
Méthodes:
RCT; Multi-Centre
Durée de l'intervention:
Follow-up assessments took place 4-6 weeks, 3-4 months and 6 months postoperatively.
Quels sont les résultats importants ?
  • Re-operation rates due to hardware failure were statistically similar between groups (3 in the DHS group [3.7%] and 2 in the MSP group [2.5%]; p>0.05). Two other re-operations were perfomed (both in the DHS group); 1 for wound debridement and 1 for hardware removal.
  • 6 patients in the MSP group and 1 patient in the DHS group experienced non-unions within the first 6 postoperative months. .
  • Hip recovery scores significantly improved from baseline to the 6-month follow-up in both groups (MSP: p<0.001; DHS: p=0.03). There were no significant between-group differences in hip recovery (MSP: 49.7%; DHS: 51.0%; p>0.05).
  • Median surgical time was significantly lower in the DHS group (50 minutes) compared to the MSP group (56 minutes) (p=0.01).
  • Tip-apex distance, as measured with radiographic images, was significantly greater in the MSP group at 6 months (p=0.02). There was no significant difference in neck-shaft angle between groups (p>0.05).
  • There was no significant difference between groups in length of hospital stay, haemoglobin drop, number of transfusions, transfusion units, leg-length discrepancy, loss in range of motion, and the incidence of complications (p>0.05).
  • At 6 months, 18 patients in the DHS group and 11 patients in the MSP group had died, a non-significant difference (p>0.05).
De quoi dois-je me souvenir en priorité ?

At 6 months, in patients with unstable intertrochanteric fractures, the use of a sliding hip screw with a Medoff sliding side plate resulted in a similar re-operation rate, hip function recovery scores, length of hospital stay, haemoglobin drop, number of transfusions, transfusion units, leg-length discrepancy, loss in range of motion, and the incidence of complications. Surgical time was significantly greater with the Medoff sliding side.

Comment cela affectera-t-il les soins prodigués à mes patients ?

Results from this study suggest that, in patients with unstable intertrochanteric fractures, the use of a sliding hip screw with a Medoff sliding side plate provides similar short-term outcome to that of a sliding hip screw with a fixed side plate. Additional higher-powered studies, using surgeons of known similar experience, are required to verify these findings.

AVIS DE NON-RESPONSABILITÉ

Le contenu de cette page est fourni à titre d'information uniquement et n'est pas destiné à remplacer un avis médical, un diagnostic ou un traitement professionnel. Si vous avez besoin d'un traitement médical, demandez toujours l'avis de votre médecin ou rendez-vous au service des urgences le plus proche. Les opinions, croyances et points de vue exprimés par les individus sur le contenu de cette page ne reflètent pas les opinions, croyances et points de vue d'OrthoEvidence.

0 de 4 articles mensuels GRATUITS débloqués
Vous avez atteint votre limite de 4 vues d'articles gratuits ce mois-ci

Accédez à OrthoEvidence pour seulement 1,99 $ par semaine.

Restez informé des dernières données. Annulez à tout moment.
  • Évaluations critiques des derniers essais contrôlés randomisés à fort impact et des revues systématiques en orthopédie.
  • Accès au contenu des podcasts OrthoEvidence, y compris les collaborations avec le Journal of Bone and Joint Surgery, les entretiens avec des chirurgiens de renommée internationale et les tables rondes sur l'actualité et les sujets orthopédiques.
  • Abonnement à The Pulse, une lettre d'information bihebdomadaire fondée sur des données probantes, conçue pour vous aider à prendre de meilleures décisions cliniques.
Upgrade
Close Dialog
Bienvenue à nouveau !
Vous avez oublié votre mot de passe ?
Commencez votre essai GRATUIT dès aujourd'hui !

Votre compte sera affilié à
et inclut un accès gratuit à OrthoEvidence.


OU
Vous avez oublié votre mot de passe ?

OU
Veuillez vérifier votre adresse électronique

Si un compte existe avec l'adresse e-mail fournie, un e-mail de réinitialisation du mot de passe vous sera envoyé. Si vous ne voyez pas d'e-mail, veuillez vérifier votre dossier de spam ou de courrier indésirable.

Pour plus d'assistance, contactez notre équipe d'assistance.

Veuillez vous connecter pour activer cette fonction

Pour accéder à cette fonctionnalité, vous devez être connecté à un compte OrthoEvidence actif. Veuillez vous connecter ou créer un compte d'essai GRATUIT.

Traduire le rapport ACE

OrthoEvidence utilise un service de traduction tiers pour rendre le contenu accessible dans plusieurs langues. Veuillez noter que même si tous les efforts sont faits pour assurer l'exactitude, les traductions ne sont pas toujours parfaites.

Comment citer ce document ACE Report

OrthoEvidence. Intertrochanteric fractures: Similar rate of reoperation using fixed or sliding side plate. OE Journal. 2014;2(7):39. Available from: https://myorthoevidence.com/AceReport/Show/intertrochanteric-fractures-similar-rate-of-reoperation-using-fixed-or-sliding-side-plate

Copier la citation
Veuillez vous connecter pour activer cette fonction

Pour accéder à cette fonctionnalité, vous devez être connecté à un compte OrthoEvidence actif. Veuillez vous connecter ou créer un compte d'essai GRATUIT.

Fonctionnalité Membre Premium

Pour accéder à cette fonctionnalité, vous devez être connecté à un compte Premium OrthoEvidence.

Partager ACE Report