FARES method leads to less pain and quicker reduction of anterior shoulder dislocation .
OrthoEvidence Journal (OE Journal) - ACE Report
OE Journal. 2013;1(11):220 Injury. 2012 Jul;43(7):1066-70. Epub 2012 Feb 12160 patients with acute anterior shoulder dislocation were randomized to either receive treatment using the FARES (fast, reliable and safe) method or the Eachempati external rotation method. The results indicate that both the FARES and Eachempati methods are safe and effective; however, the FARES method resulted in quicker reductions and decreased pain. Additionally, fewer attempts were needed to achieve reduction. The FARES method should be recommended for reduction of anterior dislocation of the shoulder.
Was the allocation sequence adequately generated?
Was allocation adequately concealed?
Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?
Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?
Blinding Patients: Was knowledge of the allocated interventions adequately prevented?
Was loss to follow-up (missing outcome data) infrequent?
Are reports of the study free of suggestion of selective outcome reporting?
Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?
Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?
Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?
Ja = 1
Ungewiss = 0.5
Nicht relevant = 0
Nein = 0
Die Bewertung der Berichtskriterien bewertet die Transparenz, mit der die Autoren die methodischen und studienspezifischen Merkmale der Studie in der Veröffentlichung angeben. Die Bewertung ist in fünf Kategorien unterteilt, die im Folgenden vorgestellt werden.
2/4
Randomization
2/4
Outcome Measurements
2/4
Inclusion / Exclusion
4/4
Therapy Description
4/4
Statistics
Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65
Der Fragilitätsindex ist ein Instrument, das bei der Interpretation signifikanter Ergebnisse hilft und ein Maß für die Stärke eines Ergebnisses liefert. Der Fragilitätsindex gibt die Anzahl der aufeinanderfolgenden Ereignisse an, die zu einem dichotomen Ergebnis hinzugefügt werden müssen, damit das Ergebnis nicht mehr signifikant ist. Eine kleine Zahl steht für ein schwächeres Ergebnis und eine große Zahl für ein stärkeres Ergebnis.
Warum wurde diese Studie jetzt benötigt?
Acute anterior dislocations of the shoulder are a frequently encountered emergency issue. There are many techniques used to reduce acute anterior shoulder dislocation, two of the newest techniques are; the Fast, Reliable and Safe (FARES) method and the Eachempati method. Although both are proven to be more effective than older methods, there have been no studies comparing these two new techniques.
Was war die wichtigste Forschungsfrage?
Are FARES and Eachempati external rotation methods safe, efficacious and reliable for the reduction of anterior shoulder dislocation and are there differences in outcome between these two methods?
- No patients had any post-reduction complications.
- 76/80 (95%) of patients in the FARES method group compared to 73/80 (91.25%) of patients in the Eachempati external rotation group achieved successful reduction of their shoulder dislocation. This was not a statistically significant difference (p=0.53, Fisher's exact test).
- There was a significant difference between groups in favour of the FARES method with respect to the speed of reduction (p<0.0001), pain felt during reduction (p<0.0001), and the number of attempts taken during reduction (p<0.0001).
Was sollte ich mir besonders merken?
Both the FARES and the Eeachempati method are safe and effective in reduction of anterior shoulder dislocation; however, the FARES method resulted in an increased speed of reduction, less pain, and this method resulted in a lower number of attempts to achieve reduction.
Wie wird sich dies auf die Behandlung meiner Patienten auswirken?
This study supports the use of the FARES method in the reduction of acute glenohumeral dislocation, as it results in quicker reductions, less pain and fewer attempts required (compared with the Eachempati method). Future studies should compare the FARES methods to various other reduction techniques.
HAFTUNGSAUSSCHLUSS
Der Inhalt dieser Seite dient nur zu Informationszwecken und ist nicht als Ersatz für professionelle medizinische Beratung, Diagnose oder Behandlung gedacht. Wenn Sie eine medizinische Behandlung benötigen, wenden Sie sich immer an Ihren Arzt oder suchen Sie die nächstgelegene Notaufnahme auf. Die Meinungen, Überzeugungen und Standpunkte, die von den Personen auf dieser Seite geäußert werden, spiegeln nicht die Meinungen, Überzeugungen und Standpunkte von OrthoEvidence wider.