Continuous low pressure suction does not reduce blood loss following TKA .
This report has been verified
by one or more authors of the
original publication.
Low- vs. high-pressure suction drainage after total knee arthroplasty: a double-blind randomized controlled trial
J Adv Nurs. 2012 Apr;68(4):758-66. doi: 10.1111/j.1365-2648.2011.05760.x. Epub 2011 Nov 14169 patients scheduled for total knee arthroplasty were randomized to receive a low- or high-pressure closed drainage system after surgery to determine if a lower suction power would reduce the total postoperative blood loss following the procedure. Blood loss following surgery was assessed until bleeding had ceased. The results indicated that there was no difference between groups in the amount of blood loss following surgery, and that the reduction of suction power did not have an effect on the total postoperative blood loss when compared to the standard high-pressure system.
Vollständigen ACE-Bericht freischalten
Sie haben Zugang zu 4 weiteren KOSTENLOSEN Artikeln in diesem Monat.
Klicken Sie unten, um diese ACE Reports freizuschalten und anzusehen
Jetzt freischalten
Kritische Beurteilungen der neuesten, hochwirksamen randomisierten kontrollierten Studien und systematischen Übersichten in der Orthopädie
Zugang zu OrthoEvidence-Podcast-Inhalten, einschließlich Kooperationen mit dem Journal of Bone and Joint Surgery, Interviews mit international anerkannten Chirurgen und Diskussionsrunden zu orthopädischen Neuigkeiten und Themen
Abonnement von The Pulse, einem zweimal wöchentlich erscheinenden evidenzbasierten Newsletter, der Ihnen helfen soll, bessere klinische Entscheidungen zu treffen
Exklusiver Zugang zu Originalartikeln, einschließlich eigener systematischer Übersichten, sowie zu Artikeln über Methoden der Gesundheitsforschung und aktuelle orthopädische Themen