COA2021: 20 Year Results of Ceramic-on-Ceramic vs Metal-on-Conventional Polyethylene Implants in THA .
Ceramic-on-Ceramic Total Hip Arthroplasty Is Superior to Metal-on-Conventional Polyethylene at 20-Year Follow-Up: A Randomised Clinical Trial
COA_2021_5One hundred and forty hips scheduled for a total hip arthroplasty were randomized to receive a metal-on-polyethylene bearing (n=69 hips) or a ceramic-on-ceramic bearing (n=71 hips). Outcomes of interest included aseptic revision rate, rate of component loosening, rate of periarticular osteolysis, the Western Ontario and McMaster University (WOMAC) osteoarthritis scores, the incidence of ceramic fracture, and implant survivorship. The minimum follow-up time was 20 years. Results revealed significantly greater survivorship, lower aseptic revision rate, lower rate of periarticular osteolysis, and greater functional scores in the ceramic-on-ceramic group compared to the metal-on-polyethylene group (p<0.05 for all). No cases of component loosening were observed in the ceramic-on-ceramic group vs 3 (13%) cases in the metal-on-polyethylene group.
افتح تقرير ACE الكامل
لديك إمكانية الوصول إلى المزيد من المقالات المجانية هذا الشهر، انقر أدناه لفتح هذا ACE Reports
افتح الآنتقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في جراحة العظام
الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، ومقابلات مع جراحين معترف بهم دوليًا، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
الاشتراك في النشرة الإخبارية The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك في اتخاذ قرارات سريرية أفضل
إمكانية الوصول الحصري إلى مقالات المحتوى الأصلي، بما في ذلك المراجعات المنهجية الداخلية، ومقالات عن طرق البحث الصحي وموضوعات جراحة العظام الساخنة