BPTB grafts fixed with bioabsorbable or metal screws show similar clinical outcome .
This report has been verified
by one or more authors of the
original publication.
A prospective randomized study of ACL-reconstructions using bone-patellar tendon-bone grafts fixed with bioabsorbable or metal interference screws
Knee Surg Sports Traumatol Arthrosc. 2011 May;19(5):753-9. doi: 10.1007/s00167-010-1353-4. Epub 2011 Jan 1441 patients were randomized to compare the clinical outcome of two different procedures following anterior cruciate ligament (ACL) reconstruction. Patients received bone-patellar tendon-bone fixed with either bioabsorbable poly-l-lactic acid screws or metal interference screws and were assessed 7 years postoperatively. Results indicated that there were no significant differences between the screws in any of the outcome measures, with the exception of Pivot-shift results (which favoured bioabsorbable screws). Moreover, while the bioabsorbable screws had degraded after 7 years, the screws were not replaced by bone.