ACE Report Cover
Autologous blood transfusion drainage versus closed suction drainage following TKA
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Lingua
Download Download Download
Scaricare
Cite this Report Cite this Report Cite this Report
Citare
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Preferiti
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Lingua
Download Download Download
Scaricare
Cite this Report Cite this Report Cite this Report
Citare
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Preferiti
ARTHROPLASTY
Autologous blood transfusion drainage versus closed suction drainage following TKA .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2017;5(6):2 BMC Musculoskelet Disord. 2016 Nov 2;17(1):452
Autori che hanno contribuito

JK Pan KH Hong H Xie MH Luo D Guo J Liu

Sixteen randomized controlled trials were included in this meta-analysis comparing autologous blood transfusion drainage and closed suction drainage following total knee arthroplasty. Results demonstrated a significantly lower incidence of allogeneic transfusion among groups treated with ABTD compared to CSD. No significant differences between drainage types were found in analyses of postoperative blood loss, postoperative hemoglobin levels, and complication rates.


Dettagli sul finanziamento della pubblicazione +
Finanziamento:
Non-Industry funded
Conflicts:
None disclosed

Rischio di pregiudizio

9/10

Criteri di segnalazione

16/20

Indice di fragilità

N/A

Were the search methods used to find evidence (original research) on the primary question or questions stated?

Was the search for evidence reasonably comprehensive?

Were the criteria used for deciding which studies to include in the overview reported?

Was the bias in the selection of studies avoided?

Were the criteria used for assessing the validity of the included studies reported?

Was the validity of all of the studies referred to in the text assessed with use of appropriate criteria (either in selecting the studies for inclusion or in analyzing the studies that were cited)?

Were the methods used to combine the findings of the relevant studies (to reach a conclusion) reported?

Were the findings of the relevant studies combined appropriately relative to the primary question that the overview addresses?

Were the conclusions made by the author or authors supported by the data and or analysis reported in the overview?

How would you rate the scientific quality of this evidence?

Sì = 1

Incerto = 0,5

Non rilevante = 0

No = 0

La valutazione dei criteri di segnalazione valuta la trasparenza con cui gli autori riportano le caratteristiche metodologiche e sperimentali dello studio all'interno della pubblicazione. La valutazione è suddivisa in cinque categorie che vengono presentate di seguito.

4/4

Introduction

3/4

Accessing Data

3/4

Analysing Data

4/4

Results

2/4

Discussion

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

L'Indice di Fragilità è uno strumento che aiuta l'interpretazione dei risultati significativi, fornendo una misura della forza di un risultato. L'Indice di Fragilità rappresenta il numero di eventi consecutivi che devono essere aggiunti a un risultato dicotomico per rendere il risultato non più significativo. Un numero piccolo rappresenta un risultato più debole, mentre un numero grande rappresenta un risultato più forte.

Perché questo studio era necessario ora?

Postoperative blood management following total knee arthroplasty procedures is an important consideration for orthopaedic surgeons. Traditional methods of management include the use of closed suction drainage (CSD) to prevent the development of hematoma postoperatively, however, many have expressed concerns that the use of closed suction drains can increase blood loss compared to no drainage and can increase the need for allogeneic transfusion. To address this, autologous blood transfusion drainage (ABTD) has been developed. Despite several randomized controlled trials that have compared results between ABTD and CSD, inconsistent findings have been obtained. A meta-analysis was needed to better assess the comparative efficacy between ABTD and CSD in blood management following total knee arthroplasty.

Qual era la domanda di ricerca principale?

How does the efficacy and safety compare between autologous blood transfusion drainage and closed suction drainage in total knee arthroplasty?

Caratteristiche dello studio +
Data Source:
PubMed, EMBASE, the Cochrane Library, the Chinese Biomedical Literature, the China National Knowledge Infrastructure, Chinese Scientific Journals, and Wanfang were searched for relevant articles published up to February 2016. Reference lists of identified articles were hand searched for any additional studies possibly missed by the electronic search.
Index Terms:
Search terms included: "drainage", "suction", "blood transfusion, autologous", "operative blood salvage", "arthroplasty, replacement, knee", "wound drainage", "closed drainage", "drainage catheter", "drainage tube", "suction drain", "surgical drainage", "drain", "wound drain", "blood autotransfusion", "autotransfusion unit", "blood salvage", "knee arthroplasty".
Study Selection:
Eligibility criteria included: a randomized controlled trial (RCT) design; enrolled patients undergoing total knee arthroplasty; allocated patients to treatment with either autologous blood transfusion drainage or closed suction drainage; and reported outcomes with appropriate data for meta-analysis. A total of sixteen randomized controlled trials, with data sampled from 1534 patients, were selected for final inclusion.
Data Extraction:
Data extraction was performed independently by two reviewers, with disagreements resolved through discussion and consensus.
Data Synthesis:
Statistical analyses were performed using Review Manager software (RevMan 5.3). Continuous outcome was expressed as weight mean differences, and dichotomous outcomes as odds ratios, both with associated 95% confidence intervals. Heterogeneity was assessed using the I-squared (I^2) statistic, and considered significant at values >50%. In the presence of significant heterogeneity, a random-effects model was used; otherwise, a fixed-effects model was used. Funnel plots were used to assess the presence of publication bias.
Quali erano i risultati importanti?
  • The incidence of allogeneic blood transfusion was significantly lower among ABTD groups (100/606) compared to CSD groups (242/597) (12 studies; OR 0.25 [95%CI 0.13-0.47]; p=0<0.0001, I-squared 77%). Assessment of funnel plot suggested the presence of publication bias.
  • The mean number of transfused units was also significantly lower with ABTD compared to CSD (5 studies; MD -0.68/patient [95%CI -0.98, -0.39]; p<0.00001, I-squared 74%).
  • No significant difference between ABTD and CSD groups was observed in the incidence of wound complications (3 studies; OR 0.98 [95%CI 0.40-2.38]; p=0.97, I-squared 0%) or the incidence of deep vein thrombosis (4/257 vs. 6/252; 4 studies; OR 0.69 [95%CI 0.21-2.24]; p=0.54, I-squared 0%).
  • No significant difference was observed in the incidence of febrile complications between ABTD groups (50/244) and CSD groups (66/257) (6 studies; OR 0.78 [95%CI 0.25-2.40]; p=0.67, I-squared 56%).
  • No significant difference between ABTD and CSD groups was observed in blood drainage volume (7 studies; MD -2.91mL [95%CI -43.50, 37.68]; p=0.89, I-squared 34%) or hemoglobin level between 5-8 days postoperatively (4 studies; MD 0.21g/dL [95%CI -0.07, 0.48]; p=0.14, I-squared 48%).
Che cosa devo ricordare di più?

In total knee arthroplasty, the use of autologous blood transfusion drainage led to a significantly lower rate of allogeneic blood transfusion when compared to closed suction drainage, though the presence publication bias could not be rejected. Otherwise, no significant differences between drainage types were observed in the incidences of wound complications, deep vein thrombosis, or febrile complications, nor postoperative blood loss volume.

Come influenzerà l'assistenza ai miei pazienti?

The results of this study suggest that autologous blood transfusion drainage systems may reduce the need for allogeneic blood transfusion when compared to closed suction drainage after total knee arthroplasty, while providing similar results regarding postoperative blood loss and complication rate. The result of this study, however, is limited by the suggestion of possible publication bias based on visual inspection of funnel plots. Additionally, many of the included studies featured small sample sizes; future trials should aim to enroll greater sample sizes to improve estimates of effect.

DISCLAIMER

Il contenuto di questa pagina è solo a scopo informativo e non intende sostituire la consulenza, la diagnosi o il trattamento medico professionale. Se ha bisogno di cure mediche, si rivolga sempre al suo medico o al pronto soccorso più vicino. Le opinioni, le convinzioni e i punti di vista espressi dalle persone sui contenuti presenti in questa pagina non riflettono le opinioni, le convinzioni e i punti di vista di OrthoEvidence.

0 di 4 articoli mensili GRATUITI sbloccati
Ha raggiunto il suo limite di 4 visualizzazioni di articoli gratuiti questo mese

Accesso a OrthoEvidence a soli 1,99 dollari a settimana.

Rimanga in contatto con le ultime prove. Può disdire in qualsiasi momento.
  • Valutazioni critiche dei più recenti studi randomizzati controllati ad alto impatto e delle revisioni sistematiche in ortopedia.
  • Accesso ai contenuti del podcast OrthoEvidence, tra cui collaborazioni con il Journal of Bone and Joint Surgery, interviste con chirurghi di fama internazionale e tavole rotonde su notizie e argomenti ortopedici.
  • Abbonamento a The Pulse, una newsletter bisettimanale basata sulle evidenze scientifiche, progettata per aiutarla a prendere decisioni cliniche migliori.
Upgrade
Bentornato!
Ha dimenticato la password?
Inizi la sua prova gratuita oggi stesso!

Il suo account sarà affiliato a
e includerà l'accesso gratuito a OrthoEvidence


O
Ha dimenticato la password?

O
Controlli la sua e-mail

Se esiste un account con l'indirizzo e-mail fornito, le verrà inviata un'e-mail di reimpostazione della password. Se non vede l'e-mail, controlli la cartella spam o posta indesiderata.

Per ulteriore assistenza, contatti il nostro team di supporto.

Effettui il login per abilitare questa funzione

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence attivo. Effettui il login o crei un account di prova GRATUITO.

Tradurre il Rapporto ACE

OrthoEvidence utilizza un servizio di traduzione di terze parti per rendere i contenuti accessibili in più lingue. Si prega di notare che, sebbene venga fatto ogni sforzo per garantire l'accuratezza, le traduzioni potrebbero non essere sempre perfette.

Come citare questo documento ACE Report

OrthoEvidence. Autologous blood transfusion drainage versus closed suction drainage following TKA. OE Journal. 2017;5(6):2. Available from: https://myorthoevidence.com/AceReport/Show/autologous-blood-transfusion-drainage-versus-closed-suction-drainage-following-tka

Copiare la citazione
Effettui il login per abilitare questa funzione

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence attivo. Effettui il login o crei un account di prova GRATUITO.

Funzionalità per i membri Premium

Per accedere a questa funzione, deve essere collegato ad un account OrthoEvidence Premium.

Condividi questo articolo ACE Report