ACE Report Cover
Analysis of various THA interventions for the treatment of end stage arthritis of the hip
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
اللغة
Download Download Download
تحميل
Cite this Report Cite this Report Cite this Report
اقتباس
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ المفضلة
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
اللغة
Download Download Download
تحميل
Cite this Report Cite this Report Cite this Report
اقتباس
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ المفضلة
ARTHROPLASTY
Analysis of various THA interventions for the treatment of end stage arthritis of the hip .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2014;2(18):14 PLoS One. 2014 Jul 8;9(7):e99804

Results from 14 RCTs and 5 systematic reviews were reviewed and pooled to determine the effect various THA interventions had on the pain, disability, and function experienced by patients with end stage arthritis of the hip. Results from the analysis indicated that patients experienced significant postoperative THA improvements in Harris Hip scores between 6 months and 10 years, but that improvements did not differ between various impact types. Additionally, a reduced risk of implant dislocation following intervention was noted for patients treated with a larger femoral head size or cemented cups (compared to smaller femoral heads and cementless cups, respectively). Those who received cross linked cup liners experienced reduced femoral head penetration and revision when compared to conventional polyethylene liners. Analysis of femoral stem fixation methods and cup shell designs indicated that neither had a significant effect on implant survival rates.


تفاصيل تمويل المنشور +
التمويل:
Non-Industry funded
الراعي:
the National Institute for Health Research, Health Technology Assessment Programm
Conflicts:
None disclosed

مخاطر التحيز

9٫5/10

معايير الإبلاغ

19/20

مؤشر الهشاشة

N/A

Were the search methods used to find evidence (original research) on the primary question or questions stated?

Was the search for evidence reasonably comprehensive?

Were the criteria used for deciding which studies to include in the overview reported?

Was the bias in the selection of studies avoided?

Were the criteria used for assessing the validity of the included studies reported?

Was the validity of all of the studies referred to in the text assessed with use of appropriate criteria (either in selecting the studies for inclusion or in analyzing the studies that were cited)?

Were the methods used to combine the findings of the relevant studies (to reach a conclusion) reported?

Were the findings of the relevant studies combined appropriately relative to the primary question that the overview addresses?

Were the conclusions made by the author or authors supported by the data and or analysis reported in the overview?

How would you rate the scientific quality of this evidence?

نعم = 1

غير مؤكد = 0.5

غير ذي صلة = 0

لا = 0

يقيّم تقييم معايير الإبلاغ الشفافية التي يبلغ بها المؤلفون عن الخصائص المنهجية والتجريبية للتجربة في المنشور. ينقسم التقييم إلى خمس فئات معروضة أدناه.

4/4

Introduction

4/4

Accessing Data

4/4

Analysing Data

4/4

Results

3/4

Discussion

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

مؤشر الهشاشة هو أداة تساعد في تفسير النتائج المهمة، وتوفر مقياسًا لقوة النتيجة. ويمثل مؤشر الهشاشة عدد الأحداث المتتالية التي يجب إضافتها إلى نتيجة ثنائية التفرع لجعل النتيجة غير مهمة. يمثل الرقم الصغير نتيجة أضعف ويمثل الرقم الكبير نتيجة أقوى.

لماذا كانت هناك حاجة لهذه الدراسة الآن؟

The enhancement of designs, fixation methods, sizes, and bearing surfaces of implants for total hip arthroplasty (THA) has produced substantial procedural options for healthcare professionals and orthopaedic surgeons. This variety of potential approaches to TKA warrants an investigation to determine the most optional combinations of THR implants and techniques. The goal of this this systematic review and meta-analysis was to evaluate the clinical effectiveness of different types of THA used for the treatment of end stage arthritis, and to attempt to determine which techniques/ interventions are the most effective.

ما هو سؤال البحث الرئيسي؟

How effective are various THA interventions at improving the pain and disability experienced by patients with end stage arthritis of the hip?

خصائص الدراسة +
Data Source:
An electronic search of the databases: MEDLINE, MEDLINE In-Process, Embase, Science Citation Index, Cochrane Library (Cochrane Database of Systematic Reviews and Cochrane Central Register of Controlled Trials), Current Controlled Trials, ClinicalTrials.gov, Database of Abstracts of Reviews of Effectiveness (DARE), and HTA databases was conducted from 2008 to December 2012.
Index Terms:
Index terms used were not provided within this report or its appendices.
Study Selection:
Authors of the study examined reports to ensure that all included studies were English language RCTs or systematic reviews comparing different types of primary THR. Populations within the studies had to include patients with end stage hip arthritis (who had failed non-surgical intervention). Studies had to be comparing the composition/material, design, bearing surface, fixation method, or size of components. Studies with a population size <100 were excluded to avoid evidence with inconclusive findings.
Data Extraction:
Two independent reviewers extracted all outcomes. Discrepancies were resolved by a third reviewer. Primary outcomes extracted were: measures of hip functions and symptoms (HHS, Oxford Hip, WOMAC), mortality and causes, risk of revision, and femoral head penetration rate. Secondary outcomes extracted were: Validated clinical/functional measures (McMaster-Toronto Arthritis patient Preference Disability Questionnaire (MACTAR), Merle D’Aubigne Postel, UCLA score, health related quality of life, and peri/post procedural complications. Study characteristics, demographic information, and intervention/comparator types were also extracted.
Data Synthesis:
Pooling of studies was based on the degree of similarity in the methodological and clinical characteristics. Post-treatment mean difference (MD) for continuous outcomes and risk ratios (RR) for binary outcomes were pooled using a random-effects-model. Dichotomous outcomes with low event rates were pooled as RR using Matel-Haenszel (MH) fixed effect models. Dichotomous outcomes for studies with very low event rates (<5.0%) or zero events in one of the treatment arms were pooled as odds ratios (OR) using the Peto fixed effect model. Heterogeneity was assessed using the I-squared statistic.
ما هي النتائج المهمة؟
  • Searches by the authors identified 1,523 unique records, of which, 14 RCTs and 5 systematic reviews were included.
  • 7 studies reported mean postoperative Harris Hip score between 6 months and 10 years. Results across the studies suggested that Harris Hip score improved in all interventions, but did not improve by significantly greater amounts when comparing patients treated with cemented and cementless cup fixation, between XLPE and transitional polyethylene cup liners, cemented and cementless stem fixation, metal on metal and metal on XLPE femoral head articulations, or ceramic on ceramic and metal on XLPE head articulations (p>0.05 for all).
  • No differences were apparent between patients treated with XLPE or traditional PE cup liners when comparing WOMAC or Short Form-12 scores (p>0.05).
  • A reduced risk of implant dislocation with the use of cemented cups was noticed when comparing its results against cementless cups (OR: 0.34, 95% CI: 0.13 to 0.89). A similar finding was found in favour of larger femoral head sizes (36 mm vs. 28 mm).
  • Three RCTs indicated that patients with XLPE cup liners experienced a reduction in femoral head penetration rate and risk of revision (RR: 0.18; 95% CI: 0.04 to 0.78) when compared to those who received conventional PE cup liners.
  • Analysis indicated that Femoral stem fixation and cup shell design had no significant effect on implant survival rates (p>0.05)
  • Patients who received ceramic on ceramic articulations experienced a reduced risk of osteolysis when compared to those treated with XLPE head articulations
ما الذي يجب أن أتذكره أكثر؟

Results from the systematic review and meta-analysis indicated that patients experienced significant postoperative THA improvements in Harris Hip scores at 6 months to 10 years, but that improvements did not differ between various impact types. A reduced risk of implant dislocation following intervention was noted for patients treated with a larger femoral head size or cemented cups (compared to smaller femoral heads and cementless cups, respectively). Those who received cross linked cup liners experienced reduced femoral head penetration and revision when compared to conventional polyethylene liners. Analysis of femoral stem fixation methods and cup shell designs indicated that neither had a significant effect on implant survival rates.

كيف سيؤثر ذلك على رعاية مرضاي؟

The majority of evidence obtained in this systematic review and meta-analysis was inconclusive due to poor reporting, missing data, or uncertain treatment estimates. The findings warrant cautious interpretation given the potential risk of bias, methodological limitations (small sample size, low event counts, short follow-up), and weak reporting of some studies included in this review. Long-term, detailed, RCTs on the topics included in this report are needed for more definitive conclusions.

تنويه

هذا المحتوى الموجود في هذه الصفحة هو لأغراض إعلامية فقط وليس الغرض منه أن يكون بديلاً عن المشورة الطبية المتخصصة أو التشخيص أو العلاج. إذا كنت بحاجة إلى علاج طبي، اطلب دائمًا مشورة طبيبك أو اذهب إلى أقرب قسم طوارئ إليك. الآراء والمعتقدات ووجهات النظر التي يعبر عنها الأفراد في المحتوى الموجود في هذه الصفحة لا تعكس آراء ومعتقدات ووجهات نظر أورثوإيفيدنس.

0 من 4 مقالات مجانية شهرية غير مقفلة
لقد وصلت إلى الحد الأقصى لمشاهدة 4 من 4 مقالات مجانية هذا الشهر

ادخل إلى OrthoEvidence مقابل 1.99 دولارًا أمريكيًا في الأسبوع.

ابق على اتصال بأحدث الأدلة. قم بالإلغاء في أي وقت.
  • تقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في مجال جراحة العظام
  • الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، والمقابلات مع الجراحين المعترف بهم دولياً، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
  • الاشتراك في نشرة The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك على اتخاذ قرارات سريرية أفضل
Upgrade
أهلاً بعودتك!
هل نسيت كلمة المرور؟
ابدأ تجربتك المجانية اليوم!

سيكون حسابك تابعًا لـ
ويتضمن وصولًا مجانيًا إلى OrthoEvidence


أو
هل نسيت كلمة المرور؟

أو
يرجى التحقق من بريدك الإلكتروني

في حالة وجود حساب بعنوان البريد الإلكتروني المقدم، سيتم إرسال بريد إلكتروني لإعادة تعيين كلمة المرور إليك. إذا كنت لا ترى بريدًا إلكترونيًا، يرجى التحقق من مجلد الرسائل غير المرغوب فيها أو البريد غير المرغوب فيه.

لمزيد من المساعدة اتصل بفريق الدعم لدينا.

يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ترجمة تقرير ACE

تستخدم OrthoEvidence خدمة ترجمة من طرف ثالث لإتاحة المحتوى بلغات متعددة. يُرجى ملاحظة أنه على الرغم من بذل كل جهد ممكن لضمان الدقة، إلا أن الترجمات قد لا تكون دائمًا مثالية.

كيفية الاستشهاد بهذا ACE Report

OrthoEvidence. Analysis of various THA interventions for the treatment of end stage arthritis of the hip. OE Journal. 2014;2(18):14. Available from: https://myorthoevidence.com/AceReport/Show/analysis-of-various-tha-interventions-for-the-treatment-of-end-stage-arthritis-of-the-hip