ACE Report Cover
AAOS: Definitive trial on impact of ultrasound in treatment of tibial fractures feasible
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Idioma
Download Download Download
Descargar
Cite this Report Cite this Report Cite this Report
Citar
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Favoritos
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
Idioma
Download Download Download
Descargar
Cite this Report Cite this Report Cite this Report
Citar
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ Favoritos
TRAUMA
AAOS: Definitive trial on impact of ultrasound in treatment of tibial fractures feasible .

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2013;1(2):242

Autores colaboradores

M Bhandari J Busse

Exclusive Author Interview

Dr. Busse speaking on the impact of ultrasound treatment for tibial shaft fractures.

51 patients with operatively treated tibial shaft fractures were randomized to either receive low-intensity pulsed ultrasound (LIPUS) or treatment with a deactivated LIPUS device, to determine what the possibility of a definitive trial would be on assessing the impact of LIPUS on patient outcomes. After collecting over a 1 year period recruitment rates, data on patient compliance to treatment, follow-up rates, and data on investigators’ ability to follow study protocol, it was determined that this pilot study supported the probability of a definitive trial in the future.


Informe de la conferencia

Este informe de la ACE es un resumen de una presentación o resumen de conferencia. La información proporcionada ha limitado la capacidad de ofrecer una evaluación precisa del riesgo de sesgo o de la calidad general. Por favor, interprete los resultados con precaución ya que los ensayos pueden estar en curso y se pueden haber presentado resultados seleccionados.

¿Por qué se necesitaba ahora este estudio?

Due to the nature of tibial fractures, a long recovery period is required. Low-intensity pulsed ultrasound (LIPUS) has been suggested as a treatment that may shorten the healing time. However, it is unclear as to what the impacts of LIPUS are on function. Hence, this study aimed to determine the likelihood of conducting a definitive trial in the future, which would assess the functional and clinical outcomes of LIPUS treatment on operatively treated tibial shaft fractures.

¿Cuál era la pregunta principal de la investigación?

What was the possibility of conducting a future definitive trial on the functional and clinical outcomes in patients receiving LIPUS treatment for operatively treated tibial shaft fractures, when measured over a 1 year period?

Características del estudio +
Población:
51 skeletally mature adults with operatively treated tibial shaft fractures (43 patients completed follow-up).
Intervención:
LIPUS Group: Patients received low-intensity pulsed ultrasound (LIPUS) treatment (n=23).
Comparación:
Sham Group: Patients received sham treatment using a deactivated LIPUS device (n=28).
Resultados:
The primary outcome measure was physical function (measured using the Short Form-36 physical component summary (SF-36 PCS) score. The secondary outcome measures were the Health Utilities Index-III (HUI-III), the Short Musculoskeletal Functional Assessment (SMFA) measure, radiographic healing time, malunion and nonunion rates, and operative and non-operative procedure rates.
Métodos:
RCT: Pilot study; Multi center; Blinded
Tiempo:
Outcomes were measured 6, 3, and 12 months following treatment
¿Cuáles fueron los hallazgos importantes?
  • The overall rate of recruitment for this pilot study was 0.8 patients per month, and 84% of patients (43) completed the 1 year follow-up.
  • In the LIPUS group 39 patients (76%) fully complied with the use of the ultrasound device, while 12 patients (24%) displayed over 50% obedience to treatment.
  • At the 6 month follow-up assessment, patients in the LIPUS group had significantly better SP-36 PCS scores (Mean difference: 6.6; 95% CI: 0.1 to 13.0; p=0.046) and HUI-III scores (Mean difference: 0.20; 95% CI: 0.01 to 0.39; p=0.035) than the Sham group.
  • SMFA measures, radiographic healing time, malunion and nonunion rates, and operative and non-operative procedure rates did not differ significantly between groups.
  • The tibia fractures that were at risk displayed significant hindrance in functional recovery compared to those fractures that were not at risk, at 9 and 12 months (9 months: p<0.001; 12 months: p=0.03).
¿Qué es lo que más debo recordar?

High patient compliance rates and and full investigator adherence to study protocols in this study pilot supported the probability of a definitive trial in the future.

¿Cómo afectará esto al cuidado de mis pacientes?

Currently a trial with a population size of 500 patients assessing the functional and clinical outcomes of LIPUS treatment on operatively treated tibial shaft fractures is being conducted. The results of that study when completed should be able to provide clarity on the effect of LIPUS on radiographic healing time, malunion and nonunion rates, and operative and non-operative procedure rates.

DESCARGO DE RESPONSABILIDAD

El contenido de esta página tiene únicamente fines informativos y no pretende sustituir el consejo, diagnóstico o tratamiento médico profesional. Si necesita tratamiento médico, busque siempre el consejo de su médico o acuda al servicio de urgencias más cercano. Las opiniones, creencias y puntos de vista expresados por las personas sobre el contenido que se encuentra en esta página no reflejan las opiniones, creencias y puntos de vista de OrthoEvidence.

0 de 4 artículos mensuales GRATIS desbloqueados
Ha alcanzado su límite de vistas de 4 artículos gratuitos este mes

Acceda a OrtoEvidencia por tan sólo 1,99 $ a la semana.

Manténgase conectado con las últimas pruebas. Cancele en cualquier momento.
  • Valoraciones críticas de los últimos ensayos controlados aleatorizados de gran impacto y revisiones sistemáticas en ortopedia
  • Acceso al contenido del podcast OrthoEvidence, que incluye colaboraciones con el Journal of Bone and Joint Surgery, entrevistas con cirujanos reconocidos internacionalmente y mesas redondas sobre noticias y temas ortopédicos
  • Suscripción a The Pulse, un boletín quincenal basado en la evidencia y diseñado para ayudarle a tomar mejores decisiones clínicas
Upgrade
Close Dialog
Bienvenido
¿Ha olvidado su contraseña?
Comience hoy mismo su prueba GRATUITA

Su cuenta estará afiliada a
e incluye acceso gratuito a OrthoEvidence


O
¿Olvidó su contraseña?

O
Compruebe su correo electrónico

Si existe una cuenta con la dirección de correo electrónico proporcionada, se le enviará un correo electrónico para restablecer la contraseña. Si no ve el correo electrónico, compruebe su carpeta de correo no deseado o spam.

Si necesita más ayuda póngase en contacto con nuestro equipo de asistencia.

Inicie sesión para activar esta función

Para acceder a esta función, debe iniciar sesión en una cuenta activa de OrthoEvidence. Por favor, inicie sesión o cree una cuenta de prueba GRATUITA.

Traducir Informe ACE

OrthoEvidence utiliza un servicio de traducción de terceros para que el contenido sea accesible en varios idiomas. Tenga en cuenta que, aunque se hace todo lo posible para garantizar la exactitud, las traducciones no siempre son perfectas.

Cómo citar esto ACE Report

OrthoEvidence. AAOS: Definitive trial on impact of ultrasound in treatment of tibial fractures feasible. OE Journal. 2013;1(2):242. Available from: https://myorthoevidence.com/AceReport/Show/aaos-definitive-trial-on-impact-of-ultrasound-in-treatment-of-tibial-fractures-feasible

Copiar cita
Inicie sesión para activar esta función

Para acceder a esta función, debe iniciar sesión en una cuenta activa de OrthoEvidence. Por favor, inicie sesión o cree una cuenta de prueba GRATUITA.

Función de miembro Premium

Para acceder a esta función, debe iniciar sesión en una cuenta Premium de OrthoEvidence.

Compartir ACE Report