ACE Report Cover
Autologous blood transfusion drainage versus closed suction drainage following TKA
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
اللغة
Download Download Download
تحميل
Cite this Report Cite this Report Cite this Report
اقتباس
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ المفضلة
Translate this  ACE Report Translate this  ACE Report Translate this  ACE Report
اللغة
Download Download Download
تحميل
Cite this Report Cite this Report Cite this Report
اقتباس
Add to Favorites Add to Favorites Add to Favorites Remove from Favorites Remove from Favorites Remove from Favorites
+ المفضلة
ARTHROPLASTY
Autologous blood transfusion drainage versus closed suction drainage following TKA .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2017;5(6):2 BMC Musculoskelet Disord. 2016 Nov 2;17(1):452
المؤلفون المساهمون

JK Pan KH Hong H Xie MH Luo D Guo J Liu

Sixteen randomized controlled trials were included in this meta-analysis comparing autologous blood transfusion drainage and closed suction drainage following total knee arthroplasty. Results demonstrated a significantly lower incidence of allogeneic transfusion among groups treated with ABTD compared to CSD. No significant differences between drainage types were found in analyses of postoperative blood loss, postoperative hemoglobin levels, and complication rates.


تفاصيل تمويل المنشور +
التمويل:
Non-Industry funded
Conflicts:
None disclosed

مخاطر التحيز

9/10

معايير الإبلاغ

16/20

مؤشر الهشاشة

N/A

Were the search methods used to find evidence (original research) on the primary question or questions stated?

Was the search for evidence reasonably comprehensive?

Were the criteria used for deciding which studies to include in the overview reported?

Was the bias in the selection of studies avoided?

Were the criteria used for assessing the validity of the included studies reported?

Was the validity of all of the studies referred to in the text assessed with use of appropriate criteria (either in selecting the studies for inclusion or in analyzing the studies that were cited)?

Were the methods used to combine the findings of the relevant studies (to reach a conclusion) reported?

Were the findings of the relevant studies combined appropriately relative to the primary question that the overview addresses?

Were the conclusions made by the author or authors supported by the data and or analysis reported in the overview?

How would you rate the scientific quality of this evidence?

نعم = 1

غير مؤكد = 0.5

غير ذي صلة = 0

لا = 0

يقيّم تقييم معايير الإبلاغ الشفافية التي يبلغ بها المؤلفون عن الخصائص المنهجية والتجريبية للتجربة في المنشور. ينقسم التقييم إلى خمس فئات معروضة أدناه.

4/4

Introduction

3/4

Accessing Data

3/4

Analysing Data

4/4

Results

2/4

Discussion

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

مؤشر الهشاشة هو أداة تساعد في تفسير النتائج المهمة، وتوفر مقياسًا لقوة النتيجة. ويمثل مؤشر الهشاشة عدد الأحداث المتتالية التي يجب إضافتها إلى نتيجة ثنائية التفرع لجعل النتيجة غير مهمة. يمثل الرقم الصغير نتيجة أضعف ويمثل الرقم الكبير نتيجة أقوى.

لماذا كانت هناك حاجة لهذه الدراسة الآن؟

Postoperative blood management following total knee arthroplasty procedures is an important consideration for orthopaedic surgeons. Traditional methods of management include the use of closed suction drainage (CSD) to prevent the development of hematoma postoperatively, however, many have expressed concerns that the use of closed suction drains can increase blood loss compared to no drainage and can increase the need for allogeneic transfusion. To address this, autologous blood transfusion drainage (ABTD) has been developed. Despite several randomized controlled trials that have compared results between ABTD and CSD, inconsistent findings have been obtained. A meta-analysis was needed to better assess the comparative efficacy between ABTD and CSD in blood management following total knee arthroplasty.

ما هو سؤال البحث الرئيسي؟

How does the efficacy and safety compare between autologous blood transfusion drainage and closed suction drainage in total knee arthroplasty?

خصائص الدراسة +
Data Source:
PubMed, EMBASE, the Cochrane Library, the Chinese Biomedical Literature, the China National Knowledge Infrastructure, Chinese Scientific Journals, and Wanfang were searched for relevant articles published up to February 2016. Reference lists of identified articles were hand searched for any additional studies possibly missed by the electronic search.
Index Terms:
Search terms included: "drainage", "suction", "blood transfusion, autologous", "operative blood salvage", "arthroplasty, replacement, knee", "wound drainage", "closed drainage", "drainage catheter", "drainage tube", "suction drain", "surgical drainage", "drain", "wound drain", "blood autotransfusion", "autotransfusion unit", "blood salvage", "knee arthroplasty".
Study Selection:
Eligibility criteria included: a randomized controlled trial (RCT) design; enrolled patients undergoing total knee arthroplasty; allocated patients to treatment with either autologous blood transfusion drainage or closed suction drainage; and reported outcomes with appropriate data for meta-analysis. A total of sixteen randomized controlled trials, with data sampled from 1534 patients, were selected for final inclusion.
Data Extraction:
Data extraction was performed independently by two reviewers, with disagreements resolved through discussion and consensus.
Data Synthesis:
Statistical analyses were performed using Review Manager software (RevMan 5.3). Continuous outcome was expressed as weight mean differences, and dichotomous outcomes as odds ratios, both with associated 95% confidence intervals. Heterogeneity was assessed using the I-squared (I^2) statistic, and considered significant at values >50%. In the presence of significant heterogeneity, a random-effects model was used; otherwise, a fixed-effects model was used. Funnel plots were used to assess the presence of publication bias.
ما هي النتائج المهمة؟
  • The incidence of allogeneic blood transfusion was significantly lower among ABTD groups (100/606) compared to CSD groups (242/597) (12 studies; OR 0.25 [95%CI 0.13-0.47]; p=0<0.0001, I-squared 77%). Assessment of funnel plot suggested the presence of publication bias.
  • The mean number of transfused units was also significantly lower with ABTD compared to CSD (5 studies; MD -0.68/patient [95%CI -0.98, -0.39]; p<0.00001, I-squared 74%).
  • No significant difference between ABTD and CSD groups was observed in the incidence of wound complications (3 studies; OR 0.98 [95%CI 0.40-2.38]; p=0.97, I-squared 0%) or the incidence of deep vein thrombosis (4/257 vs. 6/252; 4 studies; OR 0.69 [95%CI 0.21-2.24]; p=0.54, I-squared 0%).
  • No significant difference was observed in the incidence of febrile complications between ABTD groups (50/244) and CSD groups (66/257) (6 studies; OR 0.78 [95%CI 0.25-2.40]; p=0.67, I-squared 56%).
  • No significant difference between ABTD and CSD groups was observed in blood drainage volume (7 studies; MD -2.91mL [95%CI -43.50, 37.68]; p=0.89, I-squared 34%) or hemoglobin level between 5-8 days postoperatively (4 studies; MD 0.21g/dL [95%CI -0.07, 0.48]; p=0.14, I-squared 48%).
ما الذي يجب أن أتذكره أكثر؟

In total knee arthroplasty, the use of autologous blood transfusion drainage led to a significantly lower rate of allogeneic blood transfusion when compared to closed suction drainage, though the presence publication bias could not be rejected. Otherwise, no significant differences between drainage types were observed in the incidences of wound complications, deep vein thrombosis, or febrile complications, nor postoperative blood loss volume.

كيف سيؤثر ذلك على رعاية مرضاي؟

The results of this study suggest that autologous blood transfusion drainage systems may reduce the need for allogeneic blood transfusion when compared to closed suction drainage after total knee arthroplasty, while providing similar results regarding postoperative blood loss and complication rate. The result of this study, however, is limited by the suggestion of possible publication bias based on visual inspection of funnel plots. Additionally, many of the included studies featured small sample sizes; future trials should aim to enroll greater sample sizes to improve estimates of effect.

تنويه

هذا المحتوى الموجود في هذه الصفحة هو لأغراض إعلامية فقط وليس الغرض منه أن يكون بديلاً عن المشورة الطبية المتخصصة أو التشخيص أو العلاج. إذا كنت بحاجة إلى علاج طبي، اطلب دائمًا مشورة طبيبك أو اذهب إلى أقرب قسم طوارئ إليك. الآراء والمعتقدات ووجهات النظر التي يعبر عنها الأفراد في المحتوى الموجود في هذه الصفحة لا تعكس آراء ومعتقدات ووجهات نظر أورثوإيفيدنس.

0 من 4 مقالات مجانية شهرية غير مقفلة
لقد وصلت إلى الحد الأقصى لمشاهدة 4 من 4 مقالات مجانية هذا الشهر

ادخل إلى OrthoEvidence مقابل 1.99 دولارًا أمريكيًا في الأسبوع.

ابق على اتصال بأحدث الأدلة. قم بالإلغاء في أي وقت.
  • تقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في مجال جراحة العظام
  • الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، والمقابلات مع الجراحين المعترف بهم دولياً، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
  • الاشتراك في نشرة The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك على اتخاذ قرارات سريرية أفضل
Upgrade
أهلاً بعودتك!
هل نسيت كلمة المرور؟
ابدأ تجربتك المجانية اليوم!

سيكون حسابك تابعًا لـ
ويتضمن وصولًا مجانيًا إلى OrthoEvidence


أو
هل نسيت كلمة المرور؟

أو
يرجى التحقق من بريدك الإلكتروني

في حالة وجود حساب بعنوان البريد الإلكتروني المقدم، سيتم إرسال بريد إلكتروني لإعادة تعيين كلمة المرور إليك. إذا كنت لا ترى بريدًا إلكترونيًا، يرجى التحقق من مجلد الرسائل غير المرغوب فيها أو البريد غير المرغوب فيه.

لمزيد من المساعدة اتصل بفريق الدعم لدينا.

يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ترجمة تقرير ACE

تستخدم OrthoEvidence خدمة ترجمة من طرف ثالث لإتاحة المحتوى بلغات متعددة. يُرجى ملاحظة أنه على الرغم من بذل كل جهد ممكن لضمان الدقة، إلا أن الترجمات قد لا تكون دائمًا مثالية.

كيفية الاستشهاد بهذا ACE Report

OrthoEvidence. Autologous blood transfusion drainage versus closed suction drainage following TKA. OE Journal. 2017;5(6):2. Available from: https://myorthoevidence.com/AceReport/Show/

نسخ الاقتباس
يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ميزة العضو المميز

للوصول إلى هذه الميزة، يجب عليك تسجيل الدخول إلى حساب OrthoEvidence المميز.

شارك هذا ACE Report