TRAUMA
Low-intensity pulsed ultrasound improves bone healing in delayed unions of the tibia .
Verified
This report has been verified by one or more authors of the original publication.

OrthoEvidence Journal (OE Journal) - ACE Report

OE Journal. 2014;2(9):23 BMC Musculoskelet Disord. 2010 Oct 8;11:229. doi: 10.1186/1471-2474-11-229.
المؤلفون المساهمون

MD Schofer JE Block J Aigner A Schmelz

101 patients who had suffered a fracture to the tibial shaft, and for whom delayed union was confirmed were randomized to undergo 16 weeks of active low-intensity pulsed ultrasound (LIPUS) or a sham device, to determine whether LIPUS is effective in promoting bone healing in this population. Results indicated that improvements in bone mineral density (BMD) and gap area at the fracture site were significantly higher in patients treated with LIPUS compared to those treated with a sham device, with a medium degree of effectiveness in patients who completed the protocol. Furthermore, regardless of group allocations, patients whose time since fracture was 48 weeks or more experienced significantly poorer radiological outcomes, compared to fractures experienced <48 weeks prior.


تفاصيل تمويل المنشور +
التمويل:
Industry funded
الراعي:
Smith & Nephew (Memphis, TN)
Conflicts:
None disclosed

مخاطر التحيز

8/10

معايير الإبلاغ

17/20

مؤشر الهشاشة

N/A

Was the allocation sequence adequately generated?

Was allocation adequately concealed?

Blinding Treatment Providers: Was knowledge of the allocated interventions adequately prevented?

Blinding Outcome Assessors: Was knowledge of the allocated interventions adequately prevented?

Blinding Patients: Was knowledge of the allocated interventions adequately prevented?

Was loss to follow-up (missing outcome data) infrequent?

Are reports of the study free of suggestion of selective outcome reporting?

Were outcomes objective, patient-important and assessed in a manner to limit bias (ie. duplicate assessors, Independent assessors)?

Was the sample size sufficiently large to assure a balance of prognosis and sufficiently large number of outcome events?

Was investigator expertise/experience with both treatment and control techniques likely the same (ie.were criteria for surgeon participation/expertise provided)?

نعم = 1

غير مؤكد = 0.5

غير ذي صلة = 0

لا = 0

يقيّم تقييم معايير الإبلاغ الشفافية التي يبلغ بها المؤلفون عن الخصائص المنهجية والتجريبية للتجربة في المنشور. ينقسم التقييم إلى خمس فئات معروضة أدناه.

4/4

Randomization

4/4

Outcome Measurements

2/4

Inclusion / Exclusion

4/4

Therapy Description

3/4

Statistics

Detsky AS, Naylor CD, O'Rourke K, McGeer AJ, L'Abbé KA. J Clin Epidemiol. 1992;45:255-65

مؤشر الهشاشة هو أداة تساعد في تفسير النتائج المهمة، وتوفر مقياسًا لقوة النتيجة. ويمثل مؤشر الهشاشة عدد الأحداث المتتالية التي يجب إضافتها إلى نتيجة ثنائية التفرع لجعل النتيجة غير مهمة. يمثل الرقم الصغير نتيجة أضعف ويمثل الرقم الكبير نتيجة أقوى.

لماذا كانت هناك حاجة لهذه الدراسة الآن؟

Previous studies have found low-intensity pulsed ultrasound (LIPUS) to be safe and effective in promoting bone healing in numerous long-bone fracture types. This conservative treatment works by promoting osteoblastic activity, leading to subsequent increases in osteoid thickness, mineral apposition rate, as well as bone volume at the edge of new bone formation in these patients. Only a paucity of studies, the majority of which single-arm, have examined its effectiveness in patients with delayed union as opposed to fresh fractures. This study was therefore needed to contribute to the limited body of evidence in this population.

ما هو سؤال البحث الرئيسي؟

Is treatment with low-intensity pulsed ultrasound (LIPUS) for 16 weeks effective in promoting bone healing in patients with a delayed union of a tibial shaft fracture, relative to sham treatment?

خصائص الدراسة +
Population:
101 patients who had suffered a fracture to the tibial shaft, and for whom delayed union was confirmed. Delayed union was defined as a lack of clinical and radiological evidence of union, bone reaction, or bone continuity at least 16 weeks post-injury or post-treatment (n=84 completed study protocol)
Intervention:
LIPUS device group: Patients (n=51) received low-intensity pulsed ultrasound (LIPUS) using the Exogen 2000/2000+ (Smith & Nephew GmbH, Schenefeld, Germany) device, 20 minutes/day for 16 weeks. The ultrasound device was set at a frequency of 1.5 MHz, a repetition rate of 1 kHz, a pulse duration of 200 us, and a spatial intensity of 30 mW/cm^2. (Mean age: 42.6 +/- 14.6 years; 29% female)
Comparison:
Sham device group: Patients (n=50) received a sham treatment using an identical device - without emitting acoustic pressure waves - 20 minutes/day for 16 weeks. (Mean age: 45.1 +/- 11.9 years; 18% female)
Outcomes:
The primary outcomes were bone mineral density (BMD) at the fracture site, 2-3 mm proximal and distal to the index site, as well as gap area (assessed by computed tomography [CT]). BMD was measured in Hounsfield units (HUs). Compliance was also measured by the devices.
Methods:
RCT; Multi-Centre (6 sites); Double-blinded (patients & assessors)
Time:
Assessments were performed at 1, 2 and 3 months.
ما هي النتائج المهمة؟
  • Based on a descriptive 'completers' analysis (n=84), log BMD increased from baseline to 16 weeks by a mean of 0.87 HU (SD 0.67) in the treatment group and 0.57 HU (SD 0.38) in the control group. This between-group difference was statistically significant in favour of the treatment group (effect size 0.53; 95% CI 0.09, 0.97; p=0.014).
  • Also based on a descriptive 'completers' analysis (n=84), from baseline to 16 weeks, mean changes in log gap area were -0.131 mm^2 (SD 0.072) in the treatment group and -0.097 mm^2 (SD 0.070) in the control group; this between-group difference was statistically significant (effect size -0.47; 95% CI -0.91, -0.03; p=0.034).
  • Multiple imputation analysis revealed an adjusted difference between groups in the mean change in BMD of 122.4 HU (p=0.007). Based on log transformed data, the adjusted mean BMD improvement was also found to be significantly greater in the treatment group (p=0.002).
  • Using multiple imputation analysis, LIPUS was found to have a statistically significant positive effect on bone gap area (based on log transformed data) (p=0.014). A similar finding was observed for untransformed data (p=0.03).
  • Following multiple regression analysis (i.e. including pre-treatment BMD [ratio 0.64], time since fracture of <48 weeks [ratio 1.33], and use of intramedullary nail fixation [ratio 1.23]) the relative effectiveness of the treatment remained significant (p=0.004), with minimal change in magnitude.
  • Mean BMD was 1.33 times higher for patients with a time since fracture <48 weeks compared to 48 weeks or more when LIPUS status was controlled for. Despite these independent findings, a time since injury x study group interaction was not statistically significant (p=0.76), revealing that LIPUS had a significant effect on bone growth whether or not time since fracture was <48 weeks or >48 weeks. Mean BMD was 1.23 times higher for those who received intramedullary nail fixation.
  • At 16 weeks, there was a non-significant trend towards more patients in the treatment group considered "healed" (33/51 or 65%) compared to the control group (23/50 or 46%) (p=0.07).
  • No device-related adverse events were reported.
ما الذي يجب أن أتذكره أكثر؟

Improvement in bone mineral density (BMD) and gap area at the fracture site were significantly higher in patients treated with low-intensity pulsed ultrasound (LIPUS) compared to those treated with a sham device, with a medium degree of effectiveness in 'completers'. Furthermore, regardless of group allocations, patients whose time since fracture was 48 weeks or more experienced significantly poorer radiological outcomes compared to patients treated within 48 weeks of fracture.

كيف سيؤثر ذلك على رعاية مرضاي؟

Results from this study support the use of low-intensity pulsed ultrasound (LIPUS) in the treatment of delayed unions of tibial fractures. This study also emphasizes the need for early treatment when delayed unions are suspected. Additional studies with longer follow-ups are needed to confirm the longitudinal effect of this treatment approach.

تنويه

هذا المحتوى الموجود في هذه الصفحة هو لأغراض إعلامية فقط وليس الغرض منه أن يكون بديلاً عن المشورة الطبية المتخصصة أو التشخيص أو العلاج. إذا كنت بحاجة إلى علاج طبي، اطلب دائمًا مشورة طبيبك أو اذهب إلى أقرب قسم طوارئ إليك. الآراء والمعتقدات ووجهات النظر التي يعبر عنها الأفراد في المحتوى الموجود في هذه الصفحة لا تعكس آراء ومعتقدات ووجهات نظر أورثوإيفيدنس.

0 من 4 مقالات مجانية شهرية غير مقفلة
لقد وصلت إلى الحد الأقصى لمشاهدة 4 من 4 مقالات مجانية هذا الشهر

ادخل إلى OrthoEvidence مقابل 1.99 دولارًا أمريكيًا في الأسبوع.

ابق على اتصال بأحدث الأدلة. قم بالإلغاء في أي وقت.
  • تقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في مجال جراحة العظام
  • الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، والمقابلات مع الجراحين المعترف بهم دولياً، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
  • الاشتراك في نشرة The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك على اتخاذ قرارات سريرية أفضل
Upgrade
أهلاً بعودتك!
هل نسيت كلمة المرور؟
ابدأ تجربتك المجانية اليوم!

سيكون حسابك تابعًا لـ
ويتضمن وصولًا مجانيًا إلى OrthoEvidence


أو
هل نسيت كلمة المرور؟

أو
يرجى التحقق من بريدك الإلكتروني

في حالة وجود حساب بعنوان البريد الإلكتروني المقدم، سيتم إرسال بريد إلكتروني لإعادة تعيين كلمة المرور إليك. إذا كنت لا ترى بريدًا إلكترونيًا، يرجى التحقق من مجلد الرسائل غير المرغوب فيها أو البريد غير المرغوب فيه.

لمزيد من المساعدة اتصل بفريق الدعم لدينا.

يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ترجمة تقرير ACE

تستخدم OrthoEvidence خدمة ترجمة من طرف ثالث لإتاحة المحتوى بلغات متعددة. يُرجى ملاحظة أنه على الرغم من بذل كل جهد ممكن لضمان الدقة، إلا أن الترجمات قد لا تكون دائمًا مثالية.

كيفية الاستشهاد بهذا ACE Report

OrthoEvidence. Low-intensity pulsed ultrasound improves bone healing in delayed unions of the tibia. OE Journal. 2014;2(9):23. Available from: https://myorthoevidence.com/AceReport/Show/

نسخ الاقتباس
يرجى تسجيل الدخول لتفعيل هذه الميزة

للوصول إلى هذه الميزة، يجب تسجيل الدخول إلى حساب OrthoEvidence نشط. يرجى تسجيل الدخول أو إنشاء حساب تجريبي مجاني.

ميزة العضو المميز

للوصول إلى هذه الميزة، يجب عليك تسجيل الدخول إلى حساب OrthoEvidence المميز.

شارك هذا ACE Report