OTA 2013: Fractured humerus: Minimally invasive plate osteosynthesis versus open plating .
A prospective randomized study of operative treatment for noncomminuted, humeral shaft fractures: Open plating versus minimally invasive plate osteosynthesis (MIPO)
68 patients with simple-type humeral shaft fractures underwent minimally invasive plate osteosynthesis (MIPO) or conventional open plating to compare clinical, functional, and radiological outcomes. Patients in both treatment arms experienced excellent elbow and shoulder function one year postoperatively and similar rates of complication. Both groups reported a high rate of healed fractures between 15-16 weeks, 97% of fractures being healed at this time in the open plating group and 100% in the MIPO group. The only differences observed between treatments were less blood loss and a greater time of radiation exposure in the MIPO patients.
افتح تقرير ACE الكامل
لديك إمكانية الوصول إلى المزيد من المقالات المجانية هذا الشهر، انقر أدناه لفتح هذا ACE Reports
افتح الآنتقييمات نقدية لأحدث التجارب المعشاة ذات الشواهد عالية التأثير والمراجعات المنهجية في جراحة العظام
الوصول إلى محتوى المدونة الصوتية OrthoEvidence، بما في ذلك التعاون مع مجلة جراحة العظام والمفاصل، ومقابلات مع جراحين معترف بهم دوليًا، ومناقشات المائدة المستديرة حول أخبار وموضوعات جراحة العظام
الاشتراك في النشرة الإخبارية The Pulse، وهي نشرة إخبارية مبنية على الأدلة مرتين أسبوعيًا مصممة لمساعدتك في اتخاذ قرارات سريرية أفضل
إمكانية الوصول الحصري إلى مقالات المحتوى الأصلي، بما في ذلك المراجعات المنهجية الداخلية، ومقالات عن طرق البحث الصحي وموضوعات جراحة العظام الساخنة