Try Ask OE! Our NEW Advanced AI Enabled Search Dive into the Largest Database of Musculoskeletal Evidence Ask OE

ACE Reports.

+ Filters
Make a selection below to explore our full database of 26 results matching: "F Madsen"
ACE Reports
(26 Reports)
ACE Reports
Our Al driven High Impact metric predicts an article's future number of citations by considering the content of the article.
Exact search includes articles which contain all of the selected filters. Broad search includes articles that have at least one of the selected filters for each category.
Open Advanced Search
Close Advanced Search
Exact search includes articles which contain all of the selected filters. Broad search includes articles that have at least one of the selected filters for each category.
to
Exact search includes articles which contain all of the selected filters. Broad search includes articles that have at least one of the selected filters for each category.
to
ACE Report Image
Trauma
Trochanteric Stabilizing Plate for Trochanteric Fractures: No Benefit on Loss of Fracture Reduction
Bone Jt Open. 2024 01-Jan;():. 10.1302/2633-1462.51.BJO-2023-0082.R1
ACE Report Image
Shoulder & Elbow
AAOS 2024: Reverse Shoulder Arthroplasty vs. Plate Fixation: A 5-year Follow-up of the DelPhi Trial
ACE Report Image
Trauma
OTA 2023: Reverse Shoulder Arthroplasty vs. Plate Fixation for Displaced Proximal Humeral Fractures
ACE Report Image
Foot & Ankle
Patient Education for Alcohol Cessation in Acute Fracture Surgery
Acta Orthop. 2022 01-Apr;():. 10.2340/17453674.2022.2482
ACE Report Image
Hand & Wrist
Volar Locking Plate vs Dorsal Nail-Plate for Dorsal-Displaced Unstable Distal Radius Fracture
JB JS Open Access. 2021 01-Oct;():. 10.2106/JBJS.OA.21.00068
ACE Report Image
Arthroplasty
Local Leukocyte Platelet-Rich Plasma for Wound Healing After Total Hip Arthroplasty
Wound repair and regeneration : official publication of the Wound Healing Society [and] the European Tissue Repair Society. ;():. 10.1111/wrr.12967
ACE Report Image
General Orthopaedics
Similar Clinical Outcomes with a TSF Ring Fixator vs Reamed IM Nailing for Tibial Shaft Fractures
J Orthop Trauma. 2020 01-Nov;():. 10.1097/BOT.0000000000001802
ACE Report Image
Shoulder & Elbow
OTA 2020: Reverse Shoulder Arthroplasty Improves Function vs Plate Fixation for PHF in the Elderly
ACE Report Image
Arthroplasty
Reduction in intraoperative contamination with antimicrobial drapes during knee arthroplasty surgery
Clin Orthop Relat Res. 2020 01-May;():. 10.1097/CORR.0000000000001142
ACE Report Image
Trauma
Favourable 5-year clinical outcomes with suture button vs. syndesmotic screw for syndesmosis injury
The bone & joint journal. 2020 ;():. 10.1302/0301-620X.102B2.BJJ-2019-0692.R2.
ACE Report Image
Trauma
OTA 2019: Suture button superior to syndesmotic screw at five years
ACE Report Image
Hand & Wrist
High Impact
This study has been identified as potentially high impact. OE's AI-driven High Impact metric estimates the influence a paper is likely to have by integrating signals from both the journal in which it is published and the scientific content of the article itself. Developed using state-of-the-art natural language processing, the OE High Impact model more accurately predicts a study's future citation performance than journal impact factor alone. This enables earlier recognition of clinically meaningful research and helps readers focus on articles most likely to shape future practice.

Earlier recovery of function and ROM with volar plate vs external fixation for intraarticular DRFs
J Bone Joint Surg Am. 2019 Feb 20;101(4):311-321. doi: 10.2106/JBJS.18.00014
ACE Report Image
General Orthopaedics
Post-operative rotator cuff repair immobilization: 3 weeks in a sling vs. 6 weeks in a brace
Arthroscopy. 2018 Oct;34(10):2765-2774
ACE Report Image
Foot & Ankle
High Impact
This study has been identified as potentially high impact. OE's AI-driven High Impact metric estimates the influence a paper is likely to have by integrating signals from both the journal in which it is published and the scientific content of the article itself. Developed using state-of-the-art natural language processing, the OE High Impact model more accurately predicts a study's future citation performance than journal impact factor alone. This enables earlier recognition of clinically meaningful research and helps readers focus on articles most likely to shape future practice.

Better function, pain, and reduction with suture button vs screw fixation for syndesmotic injury
J Bone Joint Surg Am. 2018 Jan 3;100(1):2-12
ACE Report Image
Osteoarthritis
Comparing function between HTO approaches for patients with medial compartment knee osteoarthritis
Bone Joint J. 2017 Sep;99-B(9):1157-1166
ACE Report Image
Arthroplasty
AAOS2017: Patellofemoral arthroplasty vs TKA for patellofemoral OA
ACE Report Image
Foot & Ankle
OTA 2016: Suture endobutton versus syndesmotic screw for syndemosis injury
ACE Report Image
Arthroplasty
Uncemented stems: Higher function but increased risk of late periprosthetic fracture
Clin Orthop Relat Res. 2014 Apr;472(4):1291-9
ACE Report Image
Arthroplasty
Internal fixation VS hemiarthroplasty for hip fractures produce similar outcomes at 6 yrs
Clin Orthop Relat Res. 2014 Jan;472(1):360-7. doi: 10.1007/s11999-013-3245-7. Epub 2013 Aug 24.
ACE Report Image
Metabolic Disorders
Weight-bearing exercises in patients with diabetes mellitus and peripheral neuropathy
Phys Ther. 2010 Nov;90(11):1568-79. Epub 2010 Aug 26

Showing 1-20 of 26 results

1
2
Welcome Back!
Forgot Password?
Start your FREE trial today!

Account will be affiliated with


OR
Forgot Password?

OR
Please check your email

If an account exists with the provided email address, a password reset email will be sent to you. If you don't see an email, please check your spam or junk folder.

For further assistance, contact our support team.

Help us Improve

Provide additional feedback (optional)

Submit Feedback

Thank You!

Thank you for providing valuable feedback regarding your recent interaction with Ask OE.

Return to Ask OE